• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,818, Processing Time 0.046 seconds

Pullout Test of Headed Reinforcement (Headed Reinforcement 인발실험)

  • 박명기;신인용;최동욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.203-208
    • /
    • 2001
  • Objectives of this study included design of head and evaluation of the pullout performance of the headed reinforcement that can be used to replace standard hooks in the building exterior beam-column joints. Results of 36 pullout tests are presented. Test variables included reinforcing bar diameters (16-25mm), embedment depth (6-7db), transverse reinforcement, and single-vs.-group pullout behavior. The square head designed had gross area of 4Ab and thickness of db. The headed reinforcement made of Dl6 bars developed pullout strengths close to the bar yield strength, but larger bars developed strengths smaller than the yield strengths. The pullout resistance increased with decreasing spacing of the transverse reinforcement. Use of column ties with 6.0-db spacing improved the pullout performance of the headed bars without causing difficulties in fabricating the specimens. The comparison of the pullout performances between the headed bars and the standard hooks revealed that strengths, stiffnesses, and ductile behaviors are about the same.

  • PDF

Evaluation of rubber spring for rail vehicle and application on the floor for increasing sound insulation properties (철도차량용 방진고무의 동특성 평가 및 상구조 차음 성능 증대를 위한 적용)

  • Lee, Tae-Wook;Kim, Jong-Nyeun;Lee, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.778-782
    • /
    • 2004
  • Floating floor structure, which is mainly adopted for reducing interior noise of railway vehicle, is known that it is superior to single wall in respect of sound transmission loss. The dynamic characteristic of the support in the floating floor that is one of the important design variables in floating floor structure can change the sound and vibration insulation properties of it. From excitation test, the dynamic stiffness and loss factor of the support are evaluated. They are used as input parameter for analyzing the sound transmission loss of floating floor. Predicted transmission loss is compared with the prototype-car test results.

  • PDF

An Experimental Study on Allowable Size of Incomplete Penetration in Butt Joint Bridge Weld Considering Fatigue Strength (교량의 피로강도를 고려한 맞대기용접부 불안전용입 한계결함 결정에 관한 연구)

  • 백영남;장영권
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.68-75
    • /
    • 2000
  • The incomplete penetration(IP) discontinuity in butt joint weld, which is detected during safety analysis of the steel bridge by nondestructive evaluation(NDE) method, is classified as unacceptable defect according to the NDE codes and standards. In fact, there are a little allowance in butt joint weld in the view point of design criterion, and also detected IP discontinuity should be classified and evaluated for the fatigue strength and residual life estimation. In this study, we performed fatigue test to evaluate the fatigue strength of high strength steel(SWS490A) containing IP discontinuities in various size, the results compared and classified according to the bridge construction standard specification which published by korea administration of construction and traffic. Experimental results could be used to evaluate and estimate the IP discontinuities considering different stress range in butt joint bridge weld during periodic safety inspection.

  • PDF

Development and Evaluation of the e-learning Orientation Program for Nursing Student's Adapting to Clinical Practicum (임상실습 적응을 위한 e-learning 오리엔테이션 프로그램 개발 및 평가)

  • Yi, Yeo Jin
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.4
    • /
    • pp.593-602
    • /
    • 2007
  • Purpose: The purpose of this study was to develop an e-learning orientation program for nursing students(junior), to evaluate the program, and to find out its effects on adapting to clinical practicum. Methods: The e-learning orientation program was developed according to ADDIE model(analysis, design, develop, implement, evaluate) using an Active Tutor Program. Twelve nursing professionals and 31 nursing students(learners) evaluated the e-learning orientation program. Thirty one nursing students participated in the e-learning orientation program both on-line and off-line. Results: The e-learning orientation program consisted of 5 parts including 'Taking a lesson in gastrointestinal tract', 'Fundamental nursing skill and reading a medical chart', 'Taking a ward orientation by head nurse', 'Clinical practice with preceptors', and 'Writing for case report'. Adapting scores to clinical practicum were significantly different between pre-test and post-test(t=-5.76, p=.000). Conclusion: The e-learning orientation program of on-line and off-line has an effect on adapting to clinical practicum for nursing students.

  • PDF

Evaluation of Limit Load of Granular Pavement Materials Considering Unsaturated Shear Strength Characteristics (불포화 강도특성을 고려한 도로 입상재료의 한계하중 평가)

  • Jeon, Hye-Ji;Park, Seong-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.673-678
    • /
    • 2010
  • In this paper, the limit load of granular materials was evaluated considering unsaturated shear strength. The unsaturated shear strength parameters were estimated using the results from triaxial compression test and soil-water characteristic curves test. In addition, the limit load of different rates of materials was compared. Also, two important design parameters, yield and failure load were defined utilizing 2-D nonlinear finite element analysis respectively.

  • PDF

Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors (ㄱ형 Perfobond 리브 전단연결재의 적용성 평가)

  • Lee, Heung-Su;Chung, Chul-Hun;Kim, Byung-Suk;Kang, Jae-Yoon;Sohn, You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

Evaluation of Flexural Strength of FRP-Concrete Composite Decks According to Details of Their Connecting Parts above Girders (연결부 상세에 따른 FRP-콘크리트 합성 바닥판의 거더 위 부모멘트부 휨강도 평가)

  • Park, Sung-Yong;Cho, Keun-Hee;Kim, Sung-Tae;Cho, Jeong-Rae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.21-24
    • /
    • 2008
  • Tests were performed to obtain the flexural capacity of the innovative FRP-Concrete Composite Deck (FCCD) above girders. Test parameters were details of connection parts between FCCD and girder, such as continuity of FRP module, reinforcing ratio of FRP re-bars, and existence of shear connecting plate. As a test result, we found flexural strength of FCCD in the negative zone increases when FRP module is continuous, and reinforcement is increased, and shear connecting plate exists. And the flexural strength of all specimens give enough safety compared to the value needed in Korean highway bridge design code.

  • PDF

A Study on Multi-Axiles using ADAMS (ADAMS를 이용한 다축 시뮬레이터에 관한 연구)

  • 정찬범;유승환;이경백;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.288-291
    • /
    • 2001
  • Vehicle evaluation is performed on the proving ground, and durability test and dynamic test cost lots of money and time. Doing replace real vehicle experiment with similar experiment environment, it will take us much more useful advantages. Suspension simulator is required the robust and high-reliability and used widely. But it's natural of high-leveled control technique to manage to be fitted fluid system's property and complex that is for the lack of self-damping, nonlinearity, compressibility. In designing and evaluating simulator, it is important to understand the capability of kinematic and static performances. In this paper, an kinematic modeling and analysis has been presented using ADAMS to design that can reproduce longitudinal, lateral, and vertical force.

  • PDF

Construction and Evaluation of Scaled Korean Side Impact Dummies

  • Kim, Seong-Jin;Kwon Son;Park, Kyung-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1894-1903
    • /
    • 2003
  • It is necessary to have a dummy that describes the anthropometry of a victim with accuracy. This study presents three scaled side impact dummies constructed for the use of MADYMO. They represent five, fifty and ninety-five percentile Korean males ranged from the age of 25 through 39. Thirty-five anthropometric data were used to scale input files required for MADYSCALE. Geometries, inertia, joints and other parameters for dummies were scaled based on the configurations of EuroSID-1. This study proposes the lateral impact response requirements for head, thorax and pelvis of Korean side impact dummies. A lateral drop impact test was conducted for the head at the height of 200 mm. Lateral pendulum impact tests were also carried out for thorax and pelvis at three specific impact velocities. All these test results were obtained from simulation based on MADYMO. All the procedures of the three tests followed the requirement of ISO/TR 9790.

Seismic Performance Evaluation of Circular RC Bridge Piers with Longitudinal Steel Lap Splice (주철근 겹이음에 따른 철근 콘크리트 교각의 내진성능 평가)

  • 이대형;박진영;정영수;조대연;이재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.187-193
    • /
    • 2001
  • The object of this research is to evaluate the seismic performance of existing circular reinforced concrete bridge piers by the Quasi-static test. Existing reinforced concrete bridge piers, which were non-seismical]y designed in accordance with the conventional provisions of Korea Highway Design Specification, are needed to rating evaluate seismic performance fur probable earthquake motions in future by developing a seismic analysis computer program with estimation algorithm. This study has been performed to verify the effect of lap spliced longitudinal steel, confinement steel type and confinement steel ratio for the seismic behavior of reinforced concrete bridge piers. Quasi-static test has been done to investigate the physical seismic performance of RC bridge piers, such as displacement ductility, energy absorption, strength degradation etc.

  • PDF