• 제목/요약/키워드: Design Response Spectrum

검색결과 462건 처리시간 0.024초

일반 시설물의 지반-구조물 상호작용 해석 기준에 대한 고찰 (Overview on Standards for Soil-Structure Interaction Analysis used in Design of Infrastructure)

  • 김현욱;하정곤;김동수;주광호
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.227-236
    • /
    • 2017
  • This study reviews concepts, theories and formulas included in standards on soil-structure interaction and also shows practical example of application for engineers. Real structures are 3 dimensional and multi degree of freedom but they are often idealized to single degree of freedom for convenience. In this study, detailed procedures to calculate soil spring constants and damping coefficients and method to model soil-structure system are explained. Additionally, case studies to judge fixed base condition and evaluation of applicability of simple analysis method based on response spectra are performed.

Equivalent lateral force method for buildings with setback: adequacy in elastic range

  • Roy, Rana;Mahato, Somen
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.685-710
    • /
    • 2013
  • Static torsional provisions employing equivalent lateral force method (ELF) require that the earthquake-induced lateral force at each story be applied at a distance equal to design eccentricity ($e_d$) from a reference resistance centre of the corresponding story. Such code torsional provisions, albeit not explicitly stated, are generally believed to be applicable to the regularly asymmetric buildings. Examined herein is the applicability of such code-torsional provisions to buildings with set-back using rigid as well as flexible diaphragm model. Response of a number of set-back systems computed through ELF with static torsional provisions is compared to that by response spectrum based procedure. Influence of infill wall with a range of opening is also investigated. Results of comprehensive parametric studies suggest that the ELF may, with rational engineering judgment, be used for practical purposes taking some care of the surroundings of the setback for stiff systems in particular.

내진성능평가를 위한 비선형 직접스펙트럼법의 특성 (The Properties of a Nonlinear Direct Spectrum Method for Estimating the Seismic Performance)

  • 강병두;김재웅
    • 한국지진공학회논문집
    • /
    • 제6권4호
    • /
    • pp.65-73
    • /
    • 2002
  • 성능에 기초한 설계법에서는 비선형 응답산정이 필수적이며, 이를 위한 방법으로는 비선형시각이력해석법, 비선형 정적해석법, 비선형 효과를 고려한 등가선형해석법 등이 있다. 일부 규준에서는 pushover곡선으로부터 작성한 성능스펙트럼과 선형 응답스펙트럼으로부터 작성한 요구스펙트럼으로 이루어진 능력스펙트럼법을 제안하고 있다. 이 방법은 개념적으로는 간단하나 반복과정이 요구되며, 부정확한 결과를 산출하는 경우가 많다. 이에 따라 시행착오적인 등가선형 스펙트럼대신 비선형스펙트럼을 사용하는 방법들에 대한 연구들이 진행되고 있다. 비선형 요구스펙트럼은 표준적 선형 설계스펙트럼으로부터 결정될 수 있으며, 이 방법은 등가선형의 경우보다는 계산과정이 대폭 줄어들기는 하나 아직도 다소의 연산과정이 요구된다. 따라서 본 연구에서는 다자유도계의 구조물에 대한 pushover곡선으로부터 구조물의 진동주기와 항복강도를 구한 다음, 일련의 계산과정을 거치지 않고도, 직접적으로 비선형 최대응답을 구할 수 있는 비선형 직접스펙트럼법(NDSM)을 제시하극 집중질량계의 MDF(다자유도계) 모델에 대해 다양한 지진기록과 제하강성저하지수를 변수로 하여 NDSM의 적용성과 신뢰성을 평가하고자 한다. 본 연구의 결론은 다음과 같다. 1) 다자유도계 구조물에 대한 비선형 직접스펙트럼법에 의한 최대변위 응답은 비선형 시각이력해석법에 의한 응답과 거의 일치하므로 실용적인 방법으로 사료된다. 2) 비선형 직접스펙트럼법과 비선형 시각이력해석에 의해 산정된 죄상층 변위 결과를 비교하면, 항복후강성계수가 0.1, MAD(modal adaptive distribution)에 의한 수평정적하중분폰 그리고 제하강성저하지수가 0.2~O.3일 때 평균오차가 가장 줄어드는 것으로 나타났다.

Comparing of the effects of scaled and real earthquake records on structural response

  • Ergun, Mustafa;Ates, Sevket
    • Earthquakes and Structures
    • /
    • 제6권4호
    • /
    • pp.375-392
    • /
    • 2014
  • Time history analyses have been preferred commonly in earthquake engineering area to determine earthquake performances of structures in recent years. Advances in computer technology and structural analysis have led to common usage of time history analyses. Eurocode 8 allows the use of real earthquake records as an input for linear and nonlinear time history analyses of structures. However, real earthquake records with the desired characteristics sometimes may not be found, for example depending on soil classes, in this case artificial and synthetic earthquake records can be used for seismic analyses rather than real records. Selected earthquake records should be scaled to a code design spectrum to reduce record to record variability in structural responses of considered structures. So, scaling of earthquake records is one of the most important procedures of time history analyses. In this paper, four real earthquake records are scaled to Eurocode 8 design spectrums by using SESCAP (Selection and Scaling Program) based on time domain scaling method and developed by using MATLAB, GUI software, and then scaled and real earthquake records are used for linear time history analyses of a six-storied building. This building is modeled as spatial by SAP2000 software. The objectives of this study are to put basic procedures and criteria of selecting and scaling earthquake records in a nutshell, and to compare the effects of scaled earthquake records on structural response with the effects of real earthquake records on structural response in terms of record to record variability of structural response. Seismic analysis results of building show that record to record variability of structural response caused by scaled earthquake records are fewer than ones caused by real earthquake records.

강진지속시간 기준 개선을 위한 원전 격납구조물의 지진응답해석 (Seismic Response Analysis of NPP Containment Structures to Improve the Guidelines of Strong Motion Duration)

  • 허정원;정호섭;김재민;현창헌
    • 한국지진공학회논문집
    • /
    • 제15권4호
    • /
    • pp.33-43
    • /
    • 2011
  • 이 논문은 원전구조물의 내진설계에 적용되는 인공지진파의 강진지속시간과 포락함수에 대한 현행 국내 설계기준의 개선과 보완을 위해서 필요한 기반연구에 관한 내용을 다루고 있다. USNRC와 ASCE 4-98에서 제안한 응답스펙트럼과 강진지속시간에 대한 규정이 현재 통상적으로 사용되고 있으며, 첫 번째로 두 기준에 대한 비교와 검토를 수행하였다. 다음으로 총 209개의 암반사이트에서 실제 계측된 규모 5.0 이상인 강진기록을 ASCE 4-98의 강진지속시간기준에 적용한 결과를 통계 처리하여 지진규모에 대한 함수로 표현되는 강진지속시간의 실험적 예측모델을 제시하였다. 마지막으로 강진지속시간이 원전구조물의 지진응답특성에 미치는 영향을 파악하기 위하여 6초에서 20초까지 약 2초 간격으로 강진지속시간을 달리하는 10가지 Case에 대한 인공지진파를 각 30개씩 작성하고, 이들을 적용하여 대만 Hualien 지진시험구조물과 국내 울진 원자력발전소 원자로 격납구조물에 대한 광범위한 지진응답해석을 수행하고 그 결과를 분석하였다.

지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석 (Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank)

  • 윤장혁;강태원;양현익;전종수
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

Seismic design and elastic-plastic analysis of the hengda group super high-rise office buildings

  • Zhang, Xiaomeng;Ren, Qingying;Liu, Wenting;Yang, Songlin;Zhou, Yilun
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.175-188
    • /
    • 2020
  • The Hengda Group super high-rise building in Jinan City uses the frame-core tube structural system. With a height of 238.3 m, it is above the B-level height limit of 150 m for buildings within 7-magnitude seismic fortification zones. Therefore, it is necessary to apply performance-based seismic design to this super high-rise building. In this study, response spectrum analysis and comparative analysis of the structure are conducted using two software applications. Moreover, elastic time-history analysis, seismic analysis under an intermediate earthquake, and elastic-plastic time-history analysis under rare earthquakes are performed. Based on the analysis results, corresponding strengthening measures are implemented at weaker structural locations, such as corners, wall ends connected to framed girders, and coupling beams connected to framed girders. The failure mode and failure zone of major stress components of the structure under rare earthquakes are analysed. The conclusions to this research demonstrate that weaker locations and important parts of the structure satisfy the requirements for elastic-plastic deformation in the event of rare earthquakes.

Dynamic characteristics assessment of reactor vessel internals with fluid-structure interaction

  • Je, Sang Yun;Chang, Yoon-Suk;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1513-1523
    • /
    • 2017
  • Improvement of numerical analysis methods has been required to solve complicated phenomena that occur in nuclear facilities. Particularly, fluid-structure interaction (FSI) behavior should be resolved for accurate design and evaluation of complex reactor vessel internals (RVIs) submerged in coolant. In this study, the FSI effect on dynamic characteristics of RVIs in a typical 1,000 MWe nuclear power plant was investigated. Modal analyses of an integrated assembly were conducted by employing the fluid-structure (F-S) model as well as the traditional added-mass model. Subsequently, structural analyses were carried out using design response spectra combined with modal analysis data. Analysis results from the F-S model led to reductions of both frequency and Tresca stress compared to those values obtained using the added-mass model. Validation of the analysis method with the FSI model was also performed, from which the interface between the upper guide structure plate and the core shroud assembly lug was defined as the critical location of the typical RVIs, while all the relevant stress intensities satisfied the acceptance criteria.

계류장치 연결 위치가 Spar Type 부유식 해상풍력 발전기의 동적 응답에 미치는 영향 해석 (Analysis of Effects of Mooring Connection Position on the Dynamic Response of Spar type Floating Offshore Wind Turbine)

  • 조양욱;조진래;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.407-413
    • /
    • 2013
  • This paper deals with the analysis of dynamic characteristics of mooring system of floating-type offshore wind turbine. A spar-type floating structure which consists of a nacelle, a tower and the platform excepting blades, is used to model the floating wind turbine and connect three catenary cables to substructure. The motion of floating structure is simulated when the mooring system is attached using irregular wave Pierson-Moskowitz model. The mooring system is analyzed by changing cable position of floating structure. The dynamic behavior characteristics of mooring system are investigated comparing with cable tension and 6-dof motion of floating structure. These characteristics are much useful to initial design of floating-type structure. From the simulation results, the optimized design parameter that is cable position of connect point of mooring cable can be obtained.

Seismic evaluation and upgrading of RC buildings with weak open ground stories

  • Antonopoulos, T.A.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.611-628
    • /
    • 2012
  • The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.