• 제목/요약/키워드: Desiccant dehumidification

검색결과 49건 처리시간 0.021초

운전조건에 따른 제습로터의 제습특성과 유용도에 관한 실험적 연구 (An Experimental Study on the Dehumidification Characteristics and the Effectiveness for Operating Conditions of a Desiccant Rotor)

  • 강병하;이진주;김석현
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.29-36
    • /
    • 2012
  • An experimental study has been carried out to investigate the dehumidification characteristics for several operating conditions of a compact desiccant rotor. This problem is of particular interest in the design of a desiccant type of dehumidifier. Room temperature, room humidity, regeneration temperature, revolution speed and frontal air velocity of desiccant rotor are varied as operating conditions. The results obtained indicate that dehumidification rate is increased with an increase in the room humidity while dehumidification effectiveness is not changed much. It is also found that the optimal rotor speed and optimal regeneration temperature exist for maximum dehumidification rate and dehumidification effectiveness.

하이브리드 데시칸트 제습방식 에너지 절감 요소분석 (Energy Saving Components Analysis in Hybrid Desiccant Dehumidification System)

  • 박종일;박승태
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.603-608
    • /
    • 2015
  • The hybrid desiccant dehumidifier is an energy-effective system in comparison with the existing desiccant dehumidifier. Its main feature is to use the heat given off by the condenser as the react heat source. Through analysis of the elements for a more efficient design of the hybrid desiccant dehumidifier, it is evident that those energy-saving components do not work individually, but organically influence the efficiency of the equipment. Therefore, the hybrid desiccant dehumidifier may be an important product in the dehumidification industry.

제습로터 성능지료 제안 (A Proposal for New Definition of Performance Indices of a Desiccant Rotor)

  • 이대영;이길봉;김민수
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.537-544
    • /
    • 2007
  • To facilitate comparative analysis on the effects of numerous parameters concerning design and operation of a desiccant rotor, it is firstly required to represent the dehumidification performance as numerical indices. In this work is proposed two performance indices of a desiccant rotor: the humidity effectiveness and the enthalpy-leak ratio. The humidity effectiveness represents the actual dehumidification as compared with the dehumidification in an ideal case, while the enthalpy-leak ratio represents the enthalpy transfer from the regeneration side to the dehumidification side. In an ideal case, the two indices approach one and zero, respectively. The effects of numerous parameters on the dehumidification performance of a desiccant rotor are investigated through numerical simulation and represented with the two indices. The results show that the performance indices are mainly determined by three nondimensional parameters each representing the thermal capacity, the sorption capacity, and the transfer capacity of a desiccant rotor.

분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구 (An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System)

  • 장재철;강은철;정시영;박성룡
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

소형 흡착식 제습기의 모델 개발 (Modelling of a Small Domestic Solid Desiccant Dehumidifier)

  • 김동선
    • 융복합기술연구소 논문집
    • /
    • 제2권2호
    • /
    • pp.40-48
    • /
    • 2012
  • A small domestic desiccant dehumidifier is modelled using effectiveness models for a desiccant wheel and a wet-air condenser. The desiccant wheel and condenser models are used to compose a system model in the form of a set of simultaneous linear algebraic equations, which is solved by Gauss method. The system model is used to simulate the behaviour of a dehumidifier with a 1kW electric air heater. It is found that the maximu COP is about 0.5 and dehumidification capacity is 18kg/day when the ratio of dehumidification area is 0.7. The optimum wheel thickness and face velocity are found 100mm and 1.5m/s, respectively.

  • PDF

재생온도가 저온인 경우 제습로터의 재생부/제습부 면적비율과 회전속도 최적화 (Optimization of the Area Ratio of Regeneration to Dehumidification and Rotor Speed on the Condition of Low Regeneration Temperature)

  • 정재동;이대영;윤석만
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.521-528
    • /
    • 2007
  • The desiccant rotor is the most essential component of desiccant cooling system, but its design relies on manufacturer's experience and principles are not yet clear in spite of a lot of theoretical/experimental work published. The mathematical modeling of desiccant rotor needs solution of coupled partial differential equations of heat and mass transfer. In this study, numerical program is developed and validated using a real desiccant rotor. The calculation results are in reasonable agreement with the experimental data and other available numerical results. Optimization of desiccant rotor on the condition of low regeneration temperature are investigated. The optimal rotor speed at which the process outlet humidity becomes minimized, shows same as that of the system optimization. Compared to high regeneration temperature, broad is the range of optimal speed of low regeneration temperature. Systematic analysis on the optimal area ratio of regeneration to dehumidification section has also been conducted.

열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구 (A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device)

  • 류성룡;염호진;이현제;조현
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.618-626
    • /
    • 2018
  • In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device.

액체 건조제 냉각장치의 제습기에서 열 및 물질전달 수치해석 (A Numerical Analysis of cleat and Mass Transfer on the Dehumidifier of Liquid Desiccant Cooling System)

  • 고광호;오명도
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1756-1765
    • /
    • 2001
  • The heat and mass transfer process between the falling liquid desiccant(TEG) film and the air in counter flow at the dehumidifier of desiccant cooling system were investigated. The governing equations with appropriate boundary and interfacial conditions describing the physical problems were solved by numerical analysis. As a result, the effects of the design parameters and the outside air conditions on the rates of dehumidification and sensible cooling were discussed. The results of the dehumidification and sensible cooling rates were compared with those of the cross flow at the same conditions.

액체 건조제 제습을 위한 핀튜브형 재생기의 성능인자 영향 연구 (Study on the Effect of Performance Factors on the Finned Tube Type Regenerator for Liquid Desiccant Dehumidification)

  • 장준오;박문수;강경태;이신표;이진수
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.845-852
    • /
    • 2003
  • Liquid desiccant dehumidification system can be used effectively to save energy consumed in air conditioning as an alternative compared with conventional air conditioning systems by reducing latent heat load. The dehumidifier and the regenerator from the heart of this system. The latent part of the cooling load is handled using liquid desiccant. In this study, the experimental regenerator has been designed to study the regeneration characteristics of the aqueous triethylene glycol(TEG) system. The performance factors of the regenerator with finned tube heat exchanger were evaluated by a series of experimental runs. The regeneration process is highly dependent on the liquid desiccant conditions, such as, temperature, concentration and flow rate. In addition, the effects of the inlet air temperature, humidity and flow rate were discussed. Data obtained are useful for design guidance and performance analysis of a regenerator, particularly for a liquid desiccant cooling system.

냉각식 시스템과 비교한 복합식 제습냉방시스템의 냉각 열량증가에 관한 실험적 연구 (Study on the Energy Efficiency Improvement of Hybrid Dehumidification Air Conditioning System Compared with Refrigeration System)

  • 이수동;박문수;정진은;최영석
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.952-959
    • /
    • 2004
  • The hybrid liquid desiccant air conditioning system has been in use for many years, primarily in industrial process applications requiring dehumidification and humidity control. In this study, the hybrid dehumidifier has been designed to study the dehumidification characteristic of the aqueous triethylene glycol (TEG) solution. The experimental results show energy efficient characteristics of hybrid liquid desiccant air conditioning system compared with the refrigeration system in terms of energy use, the difference of pressure loss between hybrid liquid desiccant air conditioning system and refrigeration system. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.