• Title/Summary/Keyword: Desalting methods

Search Result 15, Processing Time 0.017 seconds

Conservation of copper objects in marine sites (해저 인양 구리 유물의 보존처리 연구)

  • Moon, Whan-Suk;Hwang, Jin-ju;Kim, Sun-Duk;Kang, Dai-Ill;Jung, Ki-Jung;Jung, Young-Dong
    • 보존과학연구
    • /
    • s.16
    • /
    • pp.41-58
    • /
    • 1995
  • Several comparisons of treatment methods for stabilizing corroded Chinese coins at Shin-an marine sites were investigated. In aqueous solution, the seexamination were performed to show whether chloride ions are gradually removed, patination changes are acceptable and archaeological details are identified. The six desalting methods showed that the orders of removal of chloride ions were ranked electrolysis (electolyte : 0.1M sodium sesqui.)> 5% sodium dithionite(1M NaOH)> 5%sodium dithionite(0.1M sesqui.)> 5% citric acid> 0.1M sodium sesquicarbonate>deionized water. As the examinations of moisture absorption to the relative humidity has compared for bronze disease, all of desalted coins for the R.H 53% and R.H 75%except to R.H 95% are showed serious bronze disease.

  • PDF

Development of Enzyme-Linked Immunosorbent Assay for Rapid and Sensitive Analysis of Biotin (Biotin의 분석을 위한 효소면역측정법(ELISA)의 개발)

  • 이경애;손동화;고영태
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.6
    • /
    • pp.1152-1159
    • /
    • 1998
  • In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.

  • PDF

Validation of LC-MS/MS Method for Analysis of Paralytic Shellfish Toxins in Shellfish and Tunicates (LC-MS/MS를 이용한 패류 및 피낭류 중 마비성 패류독소 분석법의 유효성 검증)

  • Cho, Sung Rae;Kim, Dong Wook;Yu, Hean Jae;Cho, Seong Hae;Ryu, Ara;Lee, Ka Jeong;Mok, Jong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.2
    • /
    • pp.174-180
    • /
    • 2020
  • The mouse bioassay has been used widely for the monitoring of paralytic shellfish toxins (PSTs) in many countries. However, this method shows low sensitivity and high limit of detection (LOD), as well as it cannot confirm toxic profiles. Recently, LC-MS/MS method was studied for the quantitative of PSTs, however, the method has any problems with unstable retention times by ionization suppression caused by high salt concentration in shellfish extracts. To establish an alternative method for PSTs analysis, we tried to original LC-MS/MS methods adding desalting operation using amorphous graphitized polymer carbon solid-phase extraction cartridges. The method validation was conducted to determine linearity, limit of detection, limit of quantification (LOQ), accuracy, and precision in quantifying PSTs. The correlation coefficients for all tested PSTs maintained over 0.999. The LODs and LOQs for all PSTs were about 0.19-1.05 ㎍/kg and 0.58-3.18 ㎍/kg, respectively. The accuracies for PSTs were 95.4-107.7% for saxitoxin group, 97.1-100.9% for gonyautoxin group, 99.0-100.8% for N-sulfocarbamoyl toxin group, and 96.8-104.6% for decarbamoyl toxin group. These results indicate that the modified LC-MS/MS method was appropriate for analyzing the PSTs in shellfish and tunicates.

Production of the Recombinant Single Chain Anti-B Cell Lymphoma Antibody and Evaluation of Immunoreactivity (pET vector를 통한 유전자 재조합 단일사슬 항 B형 림프종 항체의 생산과 면역반응성 평가)

  • Jung, Jae-Ho;Choi, Tae-Hyun;Woo, Kang-Sun;Chung, Wee-Sup;Kim, Soo-Gwan;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.211-217
    • /
    • 2006
  • Purpose: Recombinant ScFv lym-1 was produced, using pET vector system for large scale production. Methods: ScFv lym-1 gene inserted pET-22b (+) vector, was expressed in E.coli BL-21 strain. ScFv lym-1 antibody extracted from periplasm, was purified with His-Taq column. To evaluated immunoreactivity with Raji cell, ScFv lym-1 was labeled with I-125 and I-125 ScFv lym-1 was purified with desalting column. Raji cell was injected into the C57BR/cdJ SCID mice. Gamma camera imaging were taken time point at 1, 8, 24, and 48 hr with 8 mm pinhole collimator. Results: An active scFv lym-1 could be produced in E. coli with soluble iron using PET vector system. Immuuoreaetivity and affinity constant of IgG lym-1 were 54% and $1.83{\times}10^9M^{-1}$, respectively, and those of scFv lym-1 were 53.7% and $1.46{\times}10^9M^{-1}$, respectively. Biodistribution of I-125 scFv lym-1 antibody showed faster clearance in blood, spleen, kidney and than I-125 IgG lym-1 antibody. Gamma camera image of I-125 scFv lym-1 antibody showed faster clearance and tumor targeting liver than I-125 IgG lym-1 antibody. Conclusions: In vitro properties of scFv lym-1 were similar to those of IgG lym-1. ScFv lym-1 showed faster blood clearance than IgG lym-1 There results suggest that scFv lym-1 antibody can be useful for tumor imaging agent.

Effects of Farming Practice and NO3-N Contents of Groundwater with Different locations under Intensive Greenhouse Area (시설재배지의 재배방법 및 입지적 조건이 지하수 NO3-N 함량에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Sang;Kim, Min-Tae;Kim, Choon-Song;Kang, Ui-Gum;Kang, Hang-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate effects of fanning practice and $NO_3-N$ contents of groundwater in intensive horticultural greenhouse area of Yeongnam province, the groundwater samples from 1,370 sites were collected and analyzed. In addition, cultivation year, crops, desalinization methods, amounts of manure application, tube well depth and soil texture with clay contents were observed. Of the investigated sites, 19.7% of shallow groundwater and 1.3% of confined groundwater were exceeded over $10mg/{\ell}$ as the $NO_3-N$ drinking limit value, respectively. $NO_3-N$ concentration in groundwater was highly significantly correlative with clay content $(r=-0.241^{**})$, well depth $(r=-0.228^{**})$ and cultivation duration $(r=0.104^*)$, respectively. In case of desalting crop method being executed for desalinization of greenhouse soil, the $NO_3-N$ value of groundwater was lower than any other desalinization method. The fact that $NO_3-N$ contents of confined groundwater was affected by shallow groundwater was clarified by that $NO_3-N$ contents in shallow were significantly correlative with the confined groundwater $(r=0.532^{**})$.