Mantle Field에서 Lung Block의 선량분포 고려 (Dosimetric Consideration of the Lung Block in the Mantle Field)

  • 유명진;신병철;문창우;정태식;염하용
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.199-203
    • /
    • 1995
  • Purpose: To evaluate the dose under lung block as a function of depth and the effectiveness of a block as a function of block width. Materials and Methods : Field size of mantle field was $22.8{\times}32.4cm^2.$ Dose distribution of the mantle field was measured with two dimensional water phantom system. To analyze the effectiveness of the lung block. central axis plane, 5cm off-axis plane, and 10cm off-axis plane were studied. Results: The dose under the lung block was recorded with maximum at the depth between 5cm and 10cm. In the central axis plane, dosimetric block width was $10-15\%$ less than physical block width. In the 5cm off-axis plane, dosimetric block width was $4-9\%$ less than physical block width. In the 10cm off-axis plane, dosimetric block width was $2\%$ less than physical block width. Conclusion: Depth dependence of the dose under the lung block was founded. Also, block width dependence of the lung block was founded. To induce the accurate relation between the physical block width and the 'effective' block width, it needs more detailed understanding of the variables involved.

  • PDF

6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포 (Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator)

  • 윤주호;이철수;염하용
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제8권2호
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

3차원 입체조형치료시 Auto Contouring tool의 유용성 평가 (Evaluation of auto contouring accuracy in 3D planning system)

  • 최지민;주상규;박주영;박영환;김종식
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.35-39
    • /
    • 2002
  • Introduction : It is essential to input patients external contour in 3D treatment plan. We would like to see changes in depth and dose when 3D RTP is operating auto contouring when windows value (Width/Level) differs in this process. Material & Methode : We have analyzed the results with 3D RTP after CT Scanning with round CT Phantom. We have compared and analyzed MU values according to depth changes to Isocenter changing external contour and inputting random Window value. We have watched change values according to dose optimization in 4 directions(LAO, LPO, RAO, RPO), We plan 100 case for exact analyzation. We have results changing window value random to each beam in 100 cans. Result : It showed change between minimum and maximum value in 4 beam is Depth 0.26mm, MU $1.2\%$ in LAO. It showed LPO-Depth 0.13mm, MU $0.9\%$, RAO-Depth 0.2mm MU $0.8\%$, RPO-Depth 0.27mm, MU $1.1\%$ Conclusion : Maximum change in depth 0.27 mm, MU error rate is $0.12\%$ according to Window change. As we can see in these results, it seems Window value change doesn't effect in treatment. However, it seems there needs to select appropriate Window value in precise treatment.

  • PDF

Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Kim, Chan Hyeong;Lee, Han Rim;Jeong, Jong Hwi;Lee, Se Byeong;Shin, Dong Ho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1406-1416
    • /
    • 2019
  • In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed $3.8{\times}10^8$ protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

고에너지 광자선의 선질 지표에 관한 비교 (Comparison of Beam Quality Index of High Photon Beam)

  • 신동오;지영훈;박성용;박현주;김회남;홍성언;권수일;서태석;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.185-192
    • /
    • 1998
  • 의료용 가속기에서 방출되는 고 에너지 X-선의 정확한 흡수선량을 결정하기 위해서는 방출된 X-선의 에너지에 대한 평가가 필요하다. 의료용 가속기에서 방출되는 X-선의 에너지를 직접 측정하는 방법은 매우 어려울 뿐만 아니라 현실적이지 못하다. 따라서 고 에너지 X-선의 에너지 평가에는 선질 지표들을 사용하는 방법이 일반적으로 이용되고 있다. 선진 각 국 및 각 학회의 표준측 정법들에서는 에너지 결정 인자로서 방사선 중심축에서의 최대선량깊이, 선량곡선의 경사 및 선량 레벨과 같은 다양한 선질 지표들이 사용되고 있으며, 의료용 가속기 제작사에 따라서도 X-선 에너지 결정 인자로서 상이한 선질 지표를 사용하고 있는 실정이다. 본 연구는 위에서 언급한 다양한 선질 지표들 중에서 우리에게 가장 적합한 것을 선택하기 위하여 실시하였다. 국내에서 사용중인 11개 기관의 의료용 가속기 4종류(Mitsubishi, Scanditronix, Siemens, Varian) 18대에 대한 명목상 에너지 (4, 6, 10, 15, 21 MV) 30개에 대하여 선진 각 국 및 각 학회의 표준측정법들의 권고 및 제작사들에서 기준으로 채택하고 있는 선질 지표들로 구한 에너지를 상호 비교 분석하였다. 그 결과 명목상의 에너지가 동일하여도 가속기의 기종 및 선질 지표에 따라 에너지 분산을 보이고 있으며, 선질 지표들 중 10cm 깊이에서의 심부선량백분율을 나타내는 D$_{10}$(%)이 에너지의 분포 및 편차가 가장 적게 나타났다. 모든 선질 지표들에서 에너지가 증가함에 따라 에너지 편차는 커지는 경향을 보였다. 정확한 흡수선량 결정에 필요한 에너지 결정에 있어 명목상의 에너지와 중심축에서의 심부선량이 1대 1로 대응하는 물리적인 의미가 있는 통일된 선질 지표를 사용하는 것이 시설간의 자료 비교 및 선질 평가에 가장 바람직하다.

  • PDF

수종의 측정기에 의한 전자선의 선량 측정의 비교 (Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters)

  • 강위생
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.93-100
    • /
    • 1989
  • 전자선의 선량을 측정하기 위하여 수종의 측정기와 팬톰의 조합에 대해서 실험 및 결과를 분석하였다. 전자선의 선축상 선량분포가 조사면의 크기에 좌우되는지를 알기 위하여 실리콘 PN 접합형 다이오드를 사용하였다. 50 및 80, $90\%$ 선량점의 깊이가 작은 조사면에 대해서는 조사면의 크기에 따라 증가하지만, 큰 조사면에 대해서는 거의 일정했다. 그러나 그 깊이가 일정한 경우 최소 조사면의 크기가 뚜렷하지는 않으나 전자선의 에너지가 증가함에 따라 증가하였다. $6\~18MeV$의 전자선에 대해 조사면의 크기가 $10\times10cm^2$ 이상인 경우 그 깊이 가 어느 에너지에 대해서도 조사면의 크기에 무관함이 측정치에서 관찰되었다. 그래서 수종의 측정기와 팬톰의 결합에 따른 전자선의 선축상 선량분포의 차이점을 관찰하고자 하는 실험에서 조사면의 크기로 $10\times10cm^2$을 선택하였다. 원주형 전리함과 평판형 전리함, 필름은 폴리스티렌 팬톰과 함에, 실리콘다이오드는 물팬톤과 함께 선량측정에 이용되었다. 원주형 전리함은 표면선량이나 6MeV처럼 낮은 에너지의 선량증가 영역에서 선량을 측정할 수 없었다. 몇 가지를 제외하고는 측정된 변수들은 서로 다른 측정기 및 팬톰의 결합에 관계없이 거의 동일하였다. 어떤 에너지에서는 서로 다른 측정기에 의한 표면선량이 $4\%$ 정도 차이가 났으며, 에너지가 증가함에 따라 그 대소가 반전되기도 하였다. 18MeV의 경우 필름에 의한 80 및 $90\%$ 선량점의 깊이가 다른 측정기에 의한 것보다 꽤 얕았다. 평판형 전리함과 실리콘 다이오드는 전자선의 선량분포측정에 사용될 수 있겠으나 평판형 전리함은 큰 조사면에서만 사용하는 것이 바람직할 것이 다. 표면선량 측정이나 저 에너지 전자선의 선량증가 부분에서 선량측정에는 원주형 전리함을 사용하지 않는 것이 바람직할 것이다. 18 MeV와 같이 높은 에너지의 전자선의 선량분포 측정에 필름이 사용되어도 좋을지 의심스럽다.

  • PDF

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

Aquaplast가 광자선의 표면선량에 미치는 영향 (The Effect of Aquaplast on Surface Dose of Photon Beam)

  • 오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제13권1호
    • /
    • pp.95-100
    • /
    • 1995
  • 목적 : 두경부종양 환자의 방사선치료시 두경부의 고정에 흔히 이용되는 Aquaplast가 광자선의 표면선량에 미치는 영향을 알아보기 위하여 이 실험을 시행하였다. 재료 및 방법 : 6MV X-선(Siemens Mevatron 6740)의 표면선량과 선량증가영역의 선량을 PTW Frieburg 제작의 Markus chamber와 Capintec Model WK92 Electrometer를 이용하여 측정 하였다. $25{\times}25{\times}5cm^3$ 크기 아크릴판의 중앙에 고정된 전리함을 $25{\times}25{\times}5cm^3$ 크기의 폴리스티렌 팬톰 위에 올려 놓고 표면선량을 측정한 후 적당한 두께의 폴리스티렌 팬톰판을 올려가면서 선량증가영역의 선량을 측정하였다. 1.6mm 두께의 Aquaplast(WFR Aquaplast Corp. 제작)를 원형 그대로, 그리고 실제 환자의 고정시와 비슷한 정도로 변형시킨 상태로 전리함 위에 올려 놓은 후 각각 같은 방법으로 선량을 측정하였다. 또 트레이를 장착한 후 변형된 Aquaplast가 있는 상태에서와 없는 상태에서 각각 표면선량을 측정하였다. 모든 측정은 SSD 100cm에서 시행하였으며 $5{\times}5cm^4$, $10{\times}10cm^2$, $15{\times}15cm^2$의 세 가지 크기의 조사면에 대하여 각각 측정하였다. 표면선량과 선량증가영역의 선량 백분율은 Markus chamber의 과반응을 교정하기 위하여 Gerbi와 Khan이 제시한 식을 이용하여 구하였다. 결과 : $5{\times}5cm^2$, $10{\times}10cm^2$, $15{\times}15cm^2$의 조사면에서 표면선량은 각각 $7.9\%$, $13.6\%$, $18.7\%$ 이었고 원형 그대로의 Aquaplast가 있을 경우 표면선량은 각각 $38.4\%$, $43.6\%$, $47.4\%$ 이었으며 변형된 Aquaplast가 있을 경우의 표면선량은 각각 $31.2\%$, $36.1\%$, $40.5\%$ 이었다. 최대선량점 이상의 깊이에서는 거의 비슷한 선량 백분율을 보였다. 트레이는 조사면의 크기가 증가함에 따라 Aquaplast가 없을 경우 $0.2\%$, $1.7\%$, $3.0\%$의 표면선량 증가에 기여하였으며 변형된 Aquaplast가 있을 경우 $0.2\%$, $1.9\%$, $3.7\%$의 표면선량 증가를 보였다. 결론 : Aquaplast를 사용하지 않았을 경우에 비하여 Aquaplast를 원형 그대로 사용하였을 경우 약 $30\%$, 실제 환자의 고정시와 비슷한 정도로 변형하였을 경우 약 $22\%$의 표면선랑 증가를 가져왔으며 최대선량점 깊이 이상에서의 선량 백분율에는 건의 영향을 미치지 않았다. 실제 환자에서의 Aquaplast의 사용은 피부 및 선량증가영역의 선량을 약간 증가시키지만 임상적으로 크게 문제가 되지는 않을 것으로 생각된다.

  • PDF