• Title/Summary/Keyword: Depth Difference

Search Result 2,280, Processing Time 0.028 seconds

Seasonal variation of species composition by depths in deep sea ecosystem of the East Sea of Korea (동해 심해 생태계의 수심별 종조성 및 계절변동)

  • Sohn, Myoung-Ho;Lee, Hae-Won;Hong, Byung-Kyu;Chun, Yong-Yul
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.376-391
    • /
    • 2010
  • To investigate seasonal variation and species composition by depth layers in the deep sea ecosystem of the East Sea of Korea, bottom trawl survey was conducted at 4 depth layers during spring and autumn from 2007 to 2009. A total of 47 species were collected and were composed of 23 fish species, 9 crustacea, 6 cephalopoda and 9 gastropoda. The main dominant species at each depth layers were Chionoecetes opilio in 300m, Berryteuthis magister in 500m, Chionoecetes japonicus in 700m and 900m. In spring, richness indices (R) showed low value of 2.01 in 500m depth, and high value of 2.16 in 300m depth. Diversity indices (H') showed low value of 1.53 in 300m depth, and high value of 2.09 in 700m depth. Dominance indices (D) showed low value of 0.15 in 700m depth, and high value of 0.31 in 300m depth. In Autumn, richness indices showed low value of 1.48 in 900m depth, and high value of 2.69 in 300m depth. Diversity' indices (H') showed low value of 1.13 in 300m depth, and high value of 2.23 in 700m depth. Dominance indices (D) showed low value of 0.14 in 700m depth, and high value of 0.54 in 300m depth. In spring, similarity analysis in each depth layers showed the difference between 900m and othe depth layer, on the contrary 500m and 700m showed the similarity. In autumn, similarity analyssis in each depth layers showed the difference between 700m and other depth layers, on the contrary 300m and 500m showed the similarity.

Correction of Secondary ion Mass Spectrometry depth profile distorted by oxygen flooding (Oxygen flooding에 의해 왜곡된 SIMS depth profile의 보정)

  • 이영진;정칠성;윤명노;이순영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.225-233
    • /
    • 2001
  • Distortion of Secondary Ion Mass Spectrometry(SIMS) depth profile, which is usually observed when the analysis is made using oxygen flooding on the surface of Si with oxide on it, has been corrected. The origin of distortion has been attributed to depth calibration error due to sputter rate difference and concentration calibration error due to relative sensitivity factor(RSF) difference between $SiO_2$ and Si layers, In order to correct depth calibration error, artifact in analysis of sodium ion on oxide was used to define the interface in SIMS depth profile and oxide thickness was measured with SEM and XPS. The differences of sputter rate and RSF between two layers have been attributed to volume swelling of Si substrate occurred by oxygen flooding induced oxidation. The corrected SIMS depth profiles showed almost the same results with those obtained without oxygen flooding.

  • PDF

A Study on the Basic Shape of an MF Evaporator (MF증발기 기초 형상 설계에 관한 연구)

  • Park, Yong-Seok;Seong, Hong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

The Elderly's Error Characteristics in Some Human Interactions (자극에 대한 상호작용 관점에서의 노인의 오류 특성)

  • Jung, Kwang-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.109-115
    • /
    • 2011
  • In this research, three topics were studied for the elderly. The first was the elderly's error characteristics for tracing task and the second was for depth perception. The characteristics were compared with the young's. Twenty two old people and twenty two young people participated in the tracing experiment, respectively. In the depth perception experiment, twenty three old people and twenty two young people participated. A depth perception apparatus and a tracing one were used in the experiment. In the depth perception error, a significant difference was not detected on gender. However significant differences were detected with age and viewing distance. In the tracing error, significant difference was detected with age, also. The third experiment was push-button operation and fifteen old people participated in the experiment. As the result, operation time error was increased with the button size and the moving distance. The result of this study will be able to be considered in its user interface design to reduce the elderly's error while using a product.

Two Independent mechanisms for perception of motion in depth

  • Shioiri, Satoshi
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.25-29
    • /
    • 2000
  • Two different binocular cues are known for detecting motion in depth. One is disparity change in time and the other is inter-ocular velocity difference. Shioiri, Saisho and Yaguchi (1999) demon-strated that motion in depth can be seen based solely on inter-ocular velocity differences as well as on the disparity change in time. They used conditions in which either cue was minimized and measured performance based on motion in depth, finding better performance than chance level when either velocity cue or the disparity cue was almost isolated. However, there may have been influences from the cue minimized in each condition, since it was practically impossible to isolate perfectly either cue. I re-analyzed their data to examine whether the performance in the condition with disparity change and that in the condition with inter-ocular velocity difference were correlated. The result showed the correlation is very low and therefore, we can conclude that the visual system has two different mechanisms for motion in depth.

Intermediate Image Generation of Stereo Image Using Depth Information and Block-based Matching Method (깊이정보와 블록기반매칭을 이용한 스테레오 영상의 중간영상 생성)

  • 양광원;허경무;김장기
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.10
    • /
    • pp.874-880
    • /
    • 2002
  • A number of techniques have been proposed for 3D display using view-difference of two eyes. These methods do not express enough reality like real world. The display images have to change according to the position of a viewer to improve reality. In this paper, we present an approach for generating intermediate image between two different view images by applying new image interpolation algorithm The interpolation algorithm is designed to cope with complex shapes. The proposed image interpolation algorithm generates rotated image about vertical axes by any angle from base images. Each base image that was obtained from CCD camera has an view-angle difference of $3^{\circ}C$, $5.5^{\circ}C$, $^{\circ}C$, $22^{\circ}C$, and $45^{\circ}C$. The proposed into mediate image generation method uses the geometric analysis of image and depth information through the block-based matching method.

An Efficient Contour Coding Method Using Depth First Search Algorithm (Depth first search 알고리듬을 이용한 윤곽선 영상의 효과적인 부호화 기법)

  • 김종훈;김한수;김성대;김재균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.12
    • /
    • pp.1677-1685
    • /
    • 1988
  • In this paper, a new contour coding algorithm is investigated for use in region based image coding. Generally the contour data may be encoded by its chain codes or chain difference codes. But the data compression efficiency is low because of heavy burden for initial absolute coordinates of each chain. To alleviate this problem, the depth first search in graph traversal algorithm, is applied to the chain difference coding method. The proposed coding scheme is shown to be very efficient for contour images obtained by split-merge segmentation. Finally, we can reuce data about 60% in comparison with modified chain difference coding.

  • PDF

GPGPU based Depth Image Enhancement Algorithm (GPGPU 기반의 깊이 영상 화질 개선 기법)

  • Han, Jae-Young;Ko, Jin-Woong;Yoo, Jisang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2927-2936
    • /
    • 2013
  • In this paper, we propose a noise reduction and hole removal algorithm in order to improve the quality of depth images when they are used for creating 3D contents. In the proposed algorithm, the depth image and the corresponding color image are both used. First, an intensity image is generated by converting the RGB color space into the HSI color space. By estimating the difference of distance and depth between reference and neighbor pixels from the depth image and difference of intensity values from the color image, they are used to remove noise in the proposed algorithm. Then, the proposed hole filling method fills the detected holes with the difference of euclidean distance and intensity values between reference and neighbor pixels from the color image. Finally, we apply a parallel structure of GPGPU to the proposed algorithm to speed-up its processing time for real-time applications. The experimental results show that the proposed algorithm performs better than other conventional algorithms. Especially, the proposed algorithm is more effective in reducing edge blurring effect and removing noise and holes.

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

A Method for Precise Depth Detection in Stereoscopic Display

  • Lee Seung-Woo;Kim Nam
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.37-41
    • /
    • 2006
  • This paper discusses a method for precise depth detection in stereoscopic images. The geometry of a stereoscopic camera and a display system is presented. It was found that there exists a difference between the calculated depth and the perceived depth of objects. For precise depth detection, the proposed registration method is investigated and proved by experiment in stable condition.