Analysis about Fill Deposit Poor Drainage through Permeability Test and Groundwater Monitoring (투수시험과 지하수 모니터링을 통한 매립층의 배수불량 원인 분석)

  • Jung, Hee-Suk;Lee, Kang-Il;Kim, Joon-Seok
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.165-173
    • /
    • 2018
  • Purpose: The area such as historic sites where distributed in the hills surrounded by the mountains in the past, if heavy rains occur, soil that distributed in the substructure of a sedimentary layer's permeability decreases therefore, water do not smoothly drainage and increases surface structures' moisture content. Therefore, many phenomena occur such as the muddy ground. This experiment tried to figure out the cause of poor drainage, predicting poor drainage system when rainfall occur. So not only the base of cultural properties distributed in the historic site, but also have big influences on the upper structure. Method: We are going to propose an improvement plan through the various sites exploration and the field permeability test. In addition, analyze interrelationship to figure out the cause of the poor drainage through monitoring under ground water. Conclusion: As the result of the experiment, the cause of the poor drainage system formed on shallow depth of ground level inside of a land. We can see that soil of surface and fill deposit permeability was in poor condition. Therefore, it was in very inappropriate hydrogeological condition when surface water permeate into the underground when rainfall occurs.

A Study on Behavior of Elastic Settlement of Coastal Structure on Sandy Ground (모래층 지반 안벽구조물의 탄성침하거동 연구)

  • Yoo, Nam-Jae;Jun, Sang-Hyun;Jeon, Jin-Yong
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.201-208
    • /
    • 2007
  • This paper is research results of investigating the elastic settlement behavior of the coastal caisson structure built on the sandy deposit by comparing results of centrifuge model experiments and those of existing methods of estimating elastic settlement. Basic soil property tests such as specific gravity test, grain size distribution test and organic content test with disturbed soil sampled from the site were carried out. The centrifuge experiment of model satisfying the required design criteria was performed under 50 of artificial accelerated gravitational force condition. The Centrifuge model experimental results were compared and analyzed with the current methods of estimating settlement based on the elastic modulus obtained from the results of odeometer tests and empirical methods from literature reviews.

  • PDF

A Study of Consolidation property on Soft ground Using Piezocone (피에조콘을 이용한 연약지반의 압밀특성에 관한 연구)

  • 김봉문;박성재;정경환;김찬홍;이길환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.463-468
    • /
    • 2002
  • Based on the results obtain from the investigation of Nak-Dong River District, it was classified as very thick, soft soil deposit. Furthermore, during the construction of structures large settlements are expected. Since large settlement affects the structures life, it is very important to accurately determine the consolidation of soil based on the obtained results. In this study piezocone test and laboratory test were performed to determine the consoildtion properties of Nak-Dong River District Pusan, Gyeong-Nam province. Degree of consoildation and the coefficient of consoildation obtained from the data of piezocone test and the results of the Oedometer test were compared and analyzed. Using the results the porewater pressure coefficient($B_q$) was obtained and the relationship with the Plasticity Index was also determined. From the results of this study the effects of the degree of consolidation and consolidation coefficient, and the porewater pressure coefficient and the Plasticity Index was determined.

  • PDF

Artificial contaminated test method and leakage current characteristics of EHV insulators (송전용 애자의 인공오손시험 기법과 누설전류 특성)

  • Choi, In-Huyk;Jung, Yoon-Hwan;Choi, Jang-Hyun;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF

Deposition and Characterization of Electrophoretic Paint on AZ31 Magnesium Alloy

  • Nguyen, Van Phuong;Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.2
    • /
    • pp.141-146
    • /
    • 2016
  • In this study, electrophoretic paint (E-paint) was deposited on the knife-abraded surface of AZ31 magnesium alloy (AZ31), and its adhesion and corrosion resistance were examined by tape peel-test and salt spray test, respectively. E-paint started to deposit on AZ31 Mg alloy after an inductance time and pores were found in the E-paint layer which is ascribed to hydrogen bubbles generated on the surface during the painting process. The pores disappeared after curing for 15 min at $160^{\circ}C$. The E-paint on AZ31 exhibited good adhesion after immersion in deionized water for 500 h at $40^{\circ}C$. The E-paint sample without scratch showed no corrosion after 1500 h of salt spray test. However, on the scratched sample, blisters were visible adjacent to the scratched sites after 500 h of salt spray test.

Characteristics of Undrained Shear Strength of Yangsan Clay (양산지역 점토의 비배수 전단강도 특성)

  • 김길수;임형덕;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.71-78
    • /
    • 2000
  • SHANSEP method involves the consolidation to stresses in excess of the preconsolidation pressure in order to overcome sample disturbance effect. The concept of SHANSEP is based on an approach to laboratory test which attempts to reproduce the in-situ conditions more closely than is possible in routine tests and evaluates normalized strength parameters for the soil as a function of OCR. But SHANSEP method can be applied only to fairly uniform clay deposits, and is unsuitable for a random deposit. In this study, CK/sub o/U triaxial compression test and incremental loading consolidation test were performed for the application of SHANSEP method on Yangsan clay. During the K/sub o/-consolidation, triaxial specimens were consolidated to stress equal to two times the in-situ vertical effective stress. And for overconsolidated condition, the specimens were swelled to a known vertical effective stress in order to have the desired OCR. With the results of CK/sub o/U triaxial compression test using the block samples, the relationship between c/sub u//σ/sub vc/' and OCR on Yangsan clay was established. For evaluating the undrained shear strength of Yangsan clay with depth, CK/sub o/U triaxial compression test was performed using the piston samples taken from Yangsan site. And also undrained shear strength was analyzed from the in-situ test such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that of CK/sub o/U triaxial compression test.

  • PDF

Axisymmetric Nonlinear Consolidation Analysis for Drainage-installed Deposit Considering Secondary Compression (배수재가 설치된 연약지반의 2차압축을 고려한 축대칭 비선형 압밀해석)

  • Kim Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.133-140
    • /
    • 2005
  • In order to accelerate the rate of consolidation settlement and gain a required shear strength for a given soft clay deposit, vertical drain method combined with a preloading technique has been widely applied. In this paper, a theory of axisymmetric nonlinear consolidation fer drainage-installed deposit, which considers secondary compression (or creep) during primary consolidation, as well as the variations of compressibility and permeability during the consolidation process, has been developed. A computer program named AXICON based on Hypothesis B fur the analysis of axisymmetric nonlinear consolidation was developed by adopting finite difference method. The results of AS(ICON were compared with Hansbo's solution based on Hypothesis A, as well as in-situ settlements and pore pressures measured in test embankment of Ska-Edeby. The results indicated that Hypothesis A usually underestimated the in-situ settlement and Hypothesis B was considered to be logically correct. It was also shown that one may able to appropriately predict the real in-situ behaviors using the proposed program.

The Effects of Additives and Residual Stresses on the Electroless Nickel Plating on Carbon Substrate (첨가제와 잔류응력이 탄소 기지상 무전해 니켈도금에 미치는 영향)

  • Cheon, So-Young;Rhym, Young-Mok;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.43-48
    • /
    • 2011
  • Electroless nickel platings on carbon substrate were investigated for porous MCFC electrode applications. Acidic bath and alkaline bath were used in electroless nickel plating on carbon substrates. The rate of electroless plating in alkaline bath was faster than that in acidic bath. As pH was increased, the deposition rate was increased in both baths and the content of phosphorus in nickel deposit was decreased. The residual stresses of nickel deposit from acidic bath showed the compressive stress and on the other hand those from alkaline bath showed the high tensile stress. High tensile internal stress in nickel deposit caused the cracks over pH 11. Thiourea was added to both acidic and alkaline bath. The deposition rate of nickel was increased upto 0.5 ppm of thiourea and decreased. The maximum concentration of thiourea for the electroless nickel plating on carbon substrate was 1.5 ppm in both acidic and alkaline bath. Succinic acid was added to acidic bath. Addition of succinic acid up to 5 g/L increased the deposition rate of nickel and beyond which the deposition rate was decreased and maintained.

A study on the total housing cost of households living in rental house (임차가구의 주거비용에 관한 연구)

  • 곽인숙;김순미
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.2
    • /
    • pp.127-144
    • /
    • 1999
  • The purposes of this study were to identify the housing maintenance cost, imputed rent fee and total housing cost of households living in rental house, to analyze the factors related to their housing maintenance cost, imputed rent fee and total housing cost and to investigate the factors contributing to total housing cost to total household income ratio. The data used for these purposes, was 97 KHPS of Daewoo Economic Research Institute. Sample size of households living in rental house, was 663. Statistics performed for the analysis were frequencies, percentiles, t-test, Lorenz cutie and Gini coefficient, Tobit analysis, OLS and Logistic analysis. The results of this study were as fellows: First, monthly cost of monthly rent & maintenance and repairs of households living in rental house with a deposit was lower than rental house, while the imputed rent fee of households living rental house with a deposit was higher than monthly rent households'And, total housing cost of households living in rental house with a deposit was higher than monthly rent households'. Second, Gini coefficient of the housing maintenance cost was 0.440, Gini coefficient of imputed rent fee was 0.362, and Gini coefficient of total housing cost was 0.291. Third, the variables related to their housing maintenance cost were family type, total household expenditure of socio-demographic characteristics and residence, type of rent, housing type of housing environmental factor. Also, the variables contributing to imputed rent fee were job type and educational attainment of household hearts, the number of family members, total household expenditure, residence, type of rent, housing type and tole number of rooms. In addition, the variables associated with total housing cost were job type and educational attainment of household head, total household income and residence, type of rent, housing type and the number of room. Finally, age, job type, educational attainment of household head, wife's employment status, the number of family members, family type, total household expenditure, residence, rent type of rent, housing type, the size of living space, and the number of room were significant variables contributing to total household cost to total household income ratio.

  • PDF

Analyses of Correlation Between Groundwater Movement and Tidal Effect in West Costal Landfill Area (서해안 매립지 내 지하수유동과 조석에 관한 상관성 분석)

  • Park Jong-Oh;Song Moo-Yaung;Park Chung-Hwa
    • The Journal of Engineering Geology
    • /
    • v.16 no.3 s.49
    • /
    • pp.293-300
    • /
    • 2006
  • The groundwater movement in the west costal landfill area was analyzed by measuring N value by Standard Penetration Test, coefficient of permeability by falling head method, linear structure analysis by Digital Elevation Method, groundwater flow direction and rate by flowmeter logging due to tidal variation in the each borehole. The coefficients of permeability of the weathered zone and of the marine deposit showed similar values although some values of weathered zone show smaller values than those of the marine deposit. The major groundwater flow and rate in the marine deposit observed as east-west direction due to tidal variation, but on the other hand it was observed as N45E in weathered zone which is the major direction of the linear structures in the area. 2 hours delayed changes of the groundwater flow direction was observed during the 24 hours observation, and it seems to be a travel time of the tidal wave which cause the continuous change of the hydaulic gradient of the groundwater.