• 제목/요약/키워드: Dependency tests

검색결과 119건 처리시간 0.027초

필리멘트 와인딩 복합재 고압압력용기의 충격저항성 해석 (Analysis for Impact Damage Resistance in Filament Wound Composite Pressure Vessel)

  • 박재범;황태경;김형근;김정규;강기원
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1109-1117
    • /
    • 2005
  • To identify damage that develops in filament wound composite pressure vessels subjected to low velocity impact, a series of impact tests was performed on specimens cutting from the full scale pressure vessel. The resulting damages by the three different impactors were assessed by the scanning acoustic and metallurgical microscope. Based on the impact force history and damage, the resistance parameters were proposed and its validity in identifying the damage resistance of CFRP pressure vessel was reviewed. As the results, the impact resistance of the filament wound composites and its dependency on the impactor shape were estimated quantitatively.

레이놀즈수에 따른 이순신대교 거더에 작용하는 공기력의 변화 (Aerodynamic Forces Acting on Yi Sun-sin Bridge Girder According to Reynolds Numbers)

  • 이승호;윤자걸;권순덕
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.93-100
    • /
    • 2013
  • 본 연구에서는 트윈박스 단면인 이순신대교의 레이놀즈수 변화에 따른 공기력의 영향을 살펴보는데 그 목적이 있다. 이를 위하여 1/30 대축척 모형을 제작하여 공군사관학교 아음속 중형 풍동에서 최대 풍속 70m/s까지 풍속을 증가시켜가면서 공기력을 측정하여, 전북대학교 소형풍동에서 수행한 저레이놀즈수 풍동실험 결과와 비교하였다. 본 연구 대상 교량 단면은 레이놀즈수의 영향을 받는 것으로 나타났으며, 고레이놀즈수 실험 결과 기존 저레이놀즈수 실험보다 항력계수는 약 23%정도 낮은 수준인걸로 나타났다. 또한 경계층 촉진장치를 효과적으로 이용하면 기존의 저레이놀즈수 풍동실험 조건에서 고레이놀즈수 모사 실험이 가능한 것으로 판단된다.

베이지언 사용한 패키지 소프트웨어 인증을 위한 시험 메트릭 선택 기법 (A Method of Selecting Test Metrics for Certifying Package Software using Bayesian Belief Network)

  • 이종원;이병정;오재원;우치수
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제33권10호
    • /
    • pp.836-850
    • /
    • 2006
  • 오늘날 급속한 패키지 소프트웨어 제품의 증가 추세에 따라서, 소프트웨어 제품에 대한 품질 시험 요구 또한 증가하였다. 소프트웨어 제품 시험 시 중요한 요소는 무엇을 시험할지 기준이 되는 메트릭의 선정이다. 본 연구에서는 패키지 소프트웨어 종류를 특성 벡터들로 표현하여 메트릭들과의 연관 관계를 확률로서 세밀하게 표현한다. 특성 벡터란 소프트웨어의 형식 분류 지시자라고 할 수 있으며 특정한 패키지 소프트웨어가 다른 것들과 어떻게 구별되는지 나타낼 수 있다. 분류된 각각의 소프트웨어 형식별로 메트릭을 선정하기 위해서 과거 시험 데이타를 분석하여 활용한다. 베이지언망이 과거 데이타 분석에 이용되며 특성 벡터와 메트릭 간의 의존 관계 네트워크를 구축한다. 구축된 베이지언망은 새로운 패키지 소프트웨어 시험 작업에 적절한 메트릭을 찾아내는데 활용된다.

댐퍼 스트럿 형상에 따른 의존성 평가 (Dependency Evaluation According to Damper Strut Type)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.78-86
    • /
    • 2014
  • 본 연구의 목적은 I형 스트럿 및 S형 스트럿 강재댐퍼의 변위 및 속도의존성을 평가하는 것이다. 이를 위하여 12개의 강재댐퍼를 제작하여 의존성 평가를 실시하였으며, 시험 변수는 스트럿 형상, 목표 변위 및 속도이다. 의존성 시험에 의한 반복횟수 평가결과, ASCE 7-10에서 규정한 최소 반복횟수 5회를 충분히 상회하는 것으로 평가되었다. 변위의존성 평가결과, 큰 목표변위 (50mm)의 반복횟수 및 누적에너지소산능력은 적은 목표변위 (25mm)에 비하여 감소하였다. 또한 짧은 목표변위보다 큰 항복강도 및 조기파단을 나타내었다. 속도의존성 평가에서는 빠른 목표속도 (60mm/sec)의 반복횟수 및 누적에너지소산능력이 느린 목표속도 (40mm/sec)에 비하여 감소하였다. 결과적으로 강재댐퍼의 기본 물성, 의존성 평가, 누적에너지소산능력 평가결과, S형 스트럿을 가지는 강재댐퍼의 의존 능력이 I형보다 윌등히 우수한 것으로 평가되었다.

Zr-2.5Nb 압력관에서 Striation Spacing과 DHCV의 관계 (A Correlation of Striation Spacing and DHC Velocity in Zr-2.5Nb Tubes)

  • 최승준;안상복;박순삼;김영석
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1109-1115
    • /
    • 2004
  • The objective of this study is to elucidate what governs delayed hydride cracking (DHC) in Zr-2.5Nb tubes by correlating the striation spacings with DHCV(DHC Velocity). To this end, DHC tests were conducted on the compact tension specimens taken from the Zr-2.5Nb tubes at different temperatures ranging from 100 to $300^{\circ}C$ with a 3 to 6 data set at each test conditions. The compact tension specimens were electrolytically charged with 27 to 87 ppm H before DHC tests. After DHC tests, the striation spacings and DHCV were determined with the increasing the test temperature and yield strength. The striation spacing and DHCV increased as a function of yield $strength^2$ and the temperature. Since the plastic zone size ahead of the crack tip can be represented by ${\sim}(K_{IH}/{\sigma}_{Y})^2$, we conclude that the striation spacing is governed by the plastic zone size which in turn determines a gradient of hydrogen concentration at the crack tip. The relationship between the plastic zone size and the striation spacing was validated through a complimentary experiment using double cantilever beam specimens. Two main factors to govern DHCV of Zr-2.5Nb tubes are concluded to be hydrogen diffusion and a hydrogen concentration gradient at the crack tip that are controlled by temperature and yield strength, respectively. The activation energy of DHCV in the Zr-2.5Nb tubes is discussed on the basis of temperature dependency of hydrogen diffusion and the striation spacing.

Prediction of load transfer depth for cost-effective design of ground anchors using FBG sensors embedded tendon and numerical analysis

  • Do, Tan Manh;Kim, Young-Sang
    • Geomechanics and Engineering
    • /
    • 제10권6호
    • /
    • pp.737-755
    • /
    • 2016
  • The load transfer depth of a ground anchor is the minimum length required to transfer the initial prestressing to the grout column through the bonded part. A thorough understanding of the mechanism of load transfer as well as accurate prediction of the load transfer depth are essential for designing an anchorage that has an adequate factor of safety and satisfies implicit economic criteria. In the current research, experimental and numerical studies were conducted to investigate the load transfer mechanism of ground anchors based on a series of laboratory and field load tests. Optical FBG sensors embedded in the central king cable of a seven-wire strand were successfully employed to monitor the changes in tensile force and its distribution along the tendons. Moreover, results from laboratory and in-situ pullout tests were compared with those from equivalent case studies simulated using the finite difference method in the FLAC 3D program. All the results obtained from the two proposed methods were remarkably consistent with respect to the load increments. They were similar not only in trend but also in magnitude and showed more consistency at higher pullout loading stages, especially the final loading stage. Furthermore, the estimated load transfer depth demonstrated a pronounced dependency on the surrounding ground condition, being shorter in hard ground conditions and longer in weaker ones. Finally, considering the safety factor and cost-effective design, the required bonded length of a ground anchor was formulated in terms of the load transfer depth.

재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향 (Loading Rate Effect on the Lateral Response of H-Shape Steel Column)

  • 박민석;김철영;한종욱;채윤병
    • 대한토목학회논문집
    • /
    • 제41권6호
    • /
    • pp.637-644
    • /
    • 2021
  • 대부분 동적 성능 평가는 반복 가력 실험을 수행함으로써 구조물의 동적 응답을 평가할 수 있다. 일반적으로 강재는 재하속도 의존성 재료로 알려져 있으며 기둥 부재의 횡방향인 수평방향 가력 시 기둥 부재의 축력인 수직하중이 작용하면 부재의 응답에 영향을 미친다. 하지만, 강재 기둥 구조물의 실험 시 수평 및 수직하중을 동시에 제어하는 것이 어려워 관련 연구는 부족한 실정이다. 본 연구에서는 기둥 부재를 ATS Compensator와 FLB 시스템을 이용하여 수평 및 수직하중을 고속으로 제어하였다. 실험은 H-형 구조용 압연강재인 SS275을 이용하여 수직 하중을 제어하면서 여러 속도로 단조 및 반복 가력 실험을 수행하고 부재의 항복 하중을 비교하였다. 또한, 유한요소해석 시 재하속도에 따라 새로운 항복 응력을 제안하고 수치해석을 통해 비교하였다.

Full-scale 저경도 납면진받침의 온도의존성에 대한 실험적 연구 (Experimental Study on the Temperature Dependency of Full Scale Low Hardness Lead Rubber Bearing)

  • 박진영;장광석;이홍표;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제25권6호
    • /
    • pp.533-540
    • /
    • 2012
  • 납코어가 삽입된 적층고무받침은 주요 재료가 온도에 대한 의존성을 보유하고 있으므로 온도 환경이 장치의 성능에 미치는 영향이 적지 않다. 따라서, 본 논문에서는 대표적인 면진장치인 납면진받침에 대하여 실규모 장치를 제작하고 온도변화에 따른 강성 및 감쇠 특성변화에 대하여 실험을 통하여 분석하고 평가하였다. 실물 크기의 납면진받침을 사용하여 $-10^{\circ}C$, $0^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, $30^{\circ}C$, $40^{\circ}C$의 온도 조건에 대하여 ISO22762:2010에서 제시하고 있는 특성시험법을 적용하여 수직강성 및 수평특성에 대하여 의존성 경향을 파악하였다. 또한, 면진받침 설계 시 주요한 평가지표로 사용되는 2차강성 및 특성강도에 대하여 해외 제조사에서 제시하고 있는 온도보정식과 시험결과를 비교하였으며 수직강성에 대한 온도의존 경향을 파악하였다.

모바일 베이커리 어플리케이션에 대한 지각된 유용성과 용이성이 지속적 이용에 미치는 영향 (The Effects of Mobile Bakery Application's Perceived Usefulness and Easiness on Its Continuous Use)

  • 이명호;소영진
    • 한국조리학회지
    • /
    • 제21권2호
    • /
    • pp.171-186
    • /
    • 2015
  • 본 연구는 모바일 베이커리 어플리케이션에 대한 혁신성, 정보의존성, 정보제공 충분성 및 리뷰 신뢰성이 지각된 유용성과 지각된 용이성 그리고 최종적으로 지속적 이용에 미치는 영향관계를 검증하여 베이커리산업에 유용한 정보를 제시하고자 하였다. 자료 수집은 2014년 9월 1일부터 30일까지 실시하였으며, 설문지는 총 500부를 배포하여 455부를 회수하였고, 이 중 통계분석이 가능한 441부에 대하여 SPSS 18.0과 AMOS 18.0을 이용하여 요인분석과 신뢰성 검증을 실시하고, 제시된 연구가설을 검증하기 위해서 공분산 구조분석을 실시하였다. 분석결과, 첫째, 혁신성은 지각된 유용성과 지각된 용이성에 유의적인 영향을 미치는 것으로 나타났다. 둘째, 정보의존성은 지각된 유용성과 지각된 용이성에 유의적인 영향을 미치는 것으로 나타났다. 셋째, 정보제공 충분성은 지각된 유용성과 지각된 용이성에 유의적인 영향을 미치는 것으로 나타났다. 넷째, 리뷰신뢰성은 지각된 유용성과 지각된 용이성에 유의적인 영향을 미치는 것으로 나타났다. 다섯째, 지각된 용이성은 지각된 유용성에 유의적인 영향을 미치는 것으로 분석되었다. 마지막으로 지각된 유용성과 지각된 용이성은 모바일 베이커리 어플리케이션의 지속적 이용에 유의적인 영향을 미치는 것으로 분석되었다.

Series 60, $C_B=0.60$ 선형의 형상계수의 특성고찰 (On the Characteristics of Form Factors -Series 60, $C_B=0.60$-)

  • 김훈철;양승일;김은찬;강국진;반석호;이영길;김윤호;이귀주;곽영기;좌순원;김효철;김우전;송무석;조규종;홍성완;이승희;신영균
    • 대한조선학회지
    • /
    • 제25권4호
    • /
    • pp.7-12
    • /
    • 1988
  • 국제선형시험수조회의의 저항시험에 관한 표준선형인 Series 60, $C_B=0.60$에 대하여 서로 크기가 다른 5척의 모형선을 국내의 선형시험수조 보유기관(한국기계연구소 선박분소, 현대선박해양연구소, 서울대학교, 인하대학교)에서 제작, 교환하여 상사모형시험을 수행하였다. 이 결과를 Hughes 및 Telfer의 방법에 따라 해석하여 형상계수와 모형선의 크기 및 예인속도와의 관계를 파악하고자 했다. 이 선형에 대해서 형상계수는 Reynolds 수 뿐만 아니라 Froude 수에 따라서도 변화하는 것을 확인하였다. 또한 현행의 형상계수를 이용한 실선저항추정법이 공학적 유용성을 가지고 있음을 재확인하였다. 선형특성이 다른 여러 선형에 대해서 상사모형시험을 실시하므로서 보편적인 원리를 파악하는 것이 필요하다고 판단된다.

  • PDF