FLOW OF DENTINAL FLUID THROUGH CAT DENTINAL TUBULES IN VIVO (IN VIVO에서 고양이 상아세관을 통한 상아세관액의 흐름)

  • Son, Ho-Hyun;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.342-350
    • /
    • 1995
  • To determine the factors which affect the flow of dentinal fluid through cat dentinal tubules in vivo, the flow of fluid was measured by observing the movement of the fat droplets of dilute milk in a glass capillary with a microscope connected to the monitor. After measuring the exposed area of dentin, hydraulic conductances of dentin were calculated. The mean pressure which stoped the outward flow of dentinal fluid was 9.5mmHg. The hydraulic conductance of dentin under the condition of pulp exposed was increased by 21 % from that under the condition of dentin exposed. Under the conditions of pulp cut and pulp removed, the hydraulic conductances of dentin were increased by 22 % and 31 % respectively from that under the condition of dentin exposed. These results show that the direction and rate of dentinal fluid flow in cat dentin is affected mainly by the hydrostatic pressure of interstitial fluid of pulp tissue in the state of low compliance. Both of the osmotic effect produced by the protein constituents of interstitial fluid across the odontoblast tell layer and the change of interstitial fluid pressure produced by the state of the microcirculation of the pulp also affect the direction and rate of dentinal fluid in some degree.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

DEVELOPMENT OF NANO-FLUID MOVEMENT MEASURING DEVICE AND ITS APPLICATION TO HYDRODYNAMIC ANALYSIS OF DENTINAL FLUID (미세 물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용)

  • Lee, In-Bog;Kim, Min-Ho;Kim, Sun-Young;Chang, Ju-Hea;Cho, Byung-Hoon;Son, Ho-Hyun;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing. To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied. The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.

Real-time measurement of dentinal fluid flow during desensitizing agent application (상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정)

  • Kim, Sun-Young;Kim, Eun-Joo;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.313-320
    • /
    • 2010
  • Objectives: The aim of this study was to examine changes in the dentinal fluid flow (DFF) during desensitizing agent application and to compare permeability after application among the agents. Materials and Methods: A Class 5 cavity was prepared to exposure cervical dentin on an extracted human premolar which was connected to a sub-nanoliter fluid flow measuring device (NFMD) under 20 cm water pressure. DFF was measured from before application of desensitizing agent (Seal&Protect, SP; SuperSeal, SS; BisBlock, BB; Gluma desensitizer, GL; Bi-Fluoride 12, BF) through application procedure to 5 min after application. Results: DFF rate after each desensitizing agent application was significantly reduced when compared to initial DFF rate before application (p < 0.05). SP showed a greater reduction in DFF rate than GL and BF did (p < 0.05). SS and BB showed a greater reduction in DFF rate than BF did (p < 0.05). Conclusions: Characteristic DFF aspect of each desensitizing agent was shown in NFMD during the application procedure.

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON THE PERMEABILITY OF HUMAN DENTIN (수종의 desensitizing agent가 상아질 투과도에 미치는 영향)

  • Chon, Young-Eui;Jeong, Il-Young;Youn, Tae-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.322-329
    • /
    • 1999
  • The hydrodynamic theory of dentin sensitivity states that movement of tubular contents or tubular fluid, in either direction of dentinal tubule, causes dentin sensitivity. A corollary of that theory is that anything that can decrease dentinal fluid movement or dentin permeability should decrease dentin sensitivity. A wide variety of physicochemical methods have been used to reduce the permeability and sensitivity of exposed dentin. The purpose of this study was to evaluate the ability of 4 kinds of clinical desensitizing agents(2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$, Tubulitec system$^{(R)}$) to reduce the rate of fluid flow through dentin in vitro. Sixty coronal dentin discs, 1mm in thickness, were prepared from extracted third molars, free from decay and wear. Dentin discs were treated with 3% EDTA(Tubulicid Plus$^{(R)}$(Dental Therapeutics AB, Sweden)) to remove the smear layer and debris occluding the tubular orifices. After placing the discs in a split chamber device, the rate at which physiologic saline solution could filter across dentin under 150cm $H_2O$ hydrostatic pressure was measured. The occlusal side of the discs were then treated with MS Coat$^{(R)}$, 2% NaF, Tubulitec system$^{(R)}$, and 30% Potassium oxalate, and the filter ratio of the saline solution was measured again. The following conclusions were drawn : 1. Hydraulic conductance which was measured after the application of desensitizing agents was decreased in all the groups(p<0.05). 2. % change of hydraulic conductance was compared but no significant difference was found among the four desensitizing agents(p>0.05). 2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$ and Tubulitec system$^{(R)}$ decreased the permeability of dentin. It is considered that above four agents can be used in treating the hypersensitive teeth.

  • PDF