• Title/Summary/Keyword: Dental technique

Search Result 1,120, Processing Time 0.032 seconds

THE COMPARATIVE STUDY ON THE SEDATIVE EFFECT OF DIFFERENT INTRAVENOUS MIDAZOLAM DOSAGES FOR PEDIATRIC DENTAL PATIENTS (소아환자의 Midazolam의 정맥투여 용량에 따른 진정 효과에 관한 비교연구)

  • Kim, Eun-Young;Kim, Jong-Soo;You, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.416-426
    • /
    • 2005
  • Intravenous sedation have many advantages of rapid onset and recovery, ability of control sedation levels and duration through titration. Midazolam is most commonly used intravenous medication for sedation in pediatrics, endoscopy, oncologic procedures and so on. But in dentistry, midazolam intravenous sedation is usually for adult, and there are few reports for children. Todays, children who need sedation become more and older, intravenous sedation technique is going a matter of concern in pediatric dentistry. The purpose of this paper is to evaluate the efficacy of sedation and clinical success for different initial dosage of midazolam in intravenous sedation for pediatric dental patients. 16 healthy children (male 10, female 6), mean age $54.7{\pm}10.7$ months, who needed at least two separate treatment visits requiring local anesthesia were chosen for this study. Every children were taken 0.3mg/kg, maximum 5mg of midazolam by intramuscular route, and then 30~50% $N_2O-O_2$ for 10 minutes was given. On every visits, one of the following 2 different initial dosage was given by intravenous route : (1) Group I : 0.1mg/kg Midazolam (2) Group II : 0.2mg/kg Midazolam. Additional dosage was half of the first dose. Physiologic parameters (oxygen saturation, heart rate, respiratory rate, end-tidal carbon dioxide pressure) was recorded by ten procedure steps. Behavior was videotaped and rated using Ohio State University Behavioral Rating Scale and Automated Counting System by one investigator, blind to administered dosage. After the treatment, operator evaluated the clinical success. Physiologic parameters were stable and within normal range during treatment in both groups. The analyzed sedative effect, in behavioral evaluation, ratio of favorable Quiet was higher in group II, and clinical success rate of group II was better than group I. Induction time was rapid in group II, and recovery time was rapid in group I. And there was no statistically difference between two groups in every results.

  • PDF

An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report (회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례)

  • Lee, Ji-Hye;Lim, So-Min;Jung, Hye-Eun;Park, Chan-Jin;Cho, Lee-Ra;Kim, Dae-Gon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.209-222
    • /
    • 2011
  • Missing anterior teeth can be replaced using any of a number of methods. Patients may choose to replace missing teeth with a prosthesis that is either removable, fixed, or retained with implants. For patients faced with financial, anatomical, and/or esthetic limitations, the edentulous region can be restored successfully and esthetically with a properly designed and fabricated rotational path RPD. The rotational path RPD is a partial removable dental prosthesis that incorporates a curved, arcuate, or variable path of placement allowing one or more of the rigid components of the framework to gain access to and engage an undercut area. The rigid retainer must gain access to the infrabulge portion of the tooth by rotating into place. Either a minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface. A specially designed dovetails or asymmetric rest seats provides support and embracing effects. Correctly designed and fabricated rotational path RPD can provide improved esthetics, cleanliness, and retention. But rotational path RPDs are technique sensitive since the rotational path RPD has little margin of laboratory error that rigid retainers cannot be adjusted like conventional clasps can, RPD framework must be remade once the retention is lost. The sufficient understanding of the concept for the rotational path RPD is required for clinically successful treatment. This clinical report describes in detail the theoretical, laboratory considerations and the treatment of a patient with an anterior maxillary edentulous area treated by an AP path rotational RPD that had a difficulty in long term maintenance and describes another clinical case in which more reasonable treatment procedures were approached after analyzing the former case.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Availability of MADLDI-TOF MS for Identification of Gram Positive Bacilli Isolated from Blood Culture

  • Choi, Jin-Un;Kim, Sang-Ha;Hwang, Su-Jeong;Yu, Young-Bin;Kim, Sunghyun;Kim, Young-Kwon
    • Biomedical Science Letters
    • /
    • v.24 no.2
    • /
    • pp.108-115
    • /
    • 2018
  • In the present study, results of the identification of Gram-positive bacilli (GPB) were analyzed by using the MALDI-TOF MS technique to score each 2-year blood culture at a university hospital. In addition, 16S rRNA sequence analyses and MALDI-TOF MS results are compared to targeting strains that had been isolated two or more times within the same patient, to evaluate the usefulness of MALDI-TOF MS in GPB identification. According to the cut-off (${\geq}1.7$) criteria, there were 410 (57.5%) reliable strains and 303 (42.5%) non-identified strains among the GPB identification results of 713 strains, using a microflex MALDI Biotyper (Bruker Daltonik GmbH, Bremen, Germany). The isolation appeared most often in the following order: Corynebacterium striatum, Bacillus cereus, Bacillus subtilis, Paenibacillus urinalis, and Listeria monocytogenes. Nearly three-fourths, 66 out of 89 (74.2%) of the strains for Corynebacterium striatum; 44 out of 60 (73.3%) strains for Bacillus cereus; and all (25 out of 25, 100%) Listeria monocytogenes strains were identified by their high scores of 2.0 or higher. Most (293 strains out of 303) non-identified strains were strains isolated only once and not significant as infectious bacilli. A total of 43 out of 50 (86.0%) strains matched and were able to be identified based on the 16 rRNA sequencing comparison results of strains that were isolated twice or more within the same patient and significant as infection bacilli. Non-matching among 5 out of 7 strains was not identified, even with MALDI-TOF MS. In conclusion, GPB can be identified in blood cultures using MALDI-TOF MS. This can be done accurately with ease, rapidly, and at a low cost. It is also thought to be helpful in GPB diagnosis and treatment.

Regeneration of emergence profile with soft tissue graft and wide computer aided design/computer aided mamufacturing abutments: a clinical report (연조직 이식술과 넓은 computer aided design/computer aided mamufacturing 지대주를 이용한 임플란트 고정성 보철물의 출현윤곽 재현)

  • Kim, Min-Kyung;Lee, Ji-Hun;Ahn, Seung-Geun;Kim, Kyung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.364-370
    • /
    • 2015
  • Fixed restoration using implants for patients with posterior partial edentulism is generalized technique. As patient demands increase, the functional and esthetic implant restoration to achieve similar results to lost natural teeth is becoming an important issue. It is inevitable to use customized CAD/CAM abutments rather than ready-made abutments for the creation of implant prosthesis which closely resembles natural teeth. Using CAD/CAM abutment made it possible to obtain natural emergency profiles for posterior implant prostheses, ensuring more comfortable, efficient management of oral hygiene. However, keratinized gingiva with sufficient width and height for a natural emergence profile is required to use a large diameter CAD/CAM abutment which ensures stability and esthetics of hard/soft tissue around the implants. In this case, for esthetical and functional implant zirconia prosthesis, soft tissue graft was performed and customized CAD/CAM abutments were used following ridge augmentation, sinus graft and implantation. Satisfactory results were obtained functionally and esthetically through periodic clinical evaluation, and I hereby report this case.

Evaluation of clinical outcomes of implants placed into the maxillary sinus with a perforated sinus membrane: a retrospective study

  • Kim, Gwang-Seok;Lee, Jae-Wang;Chong, Jong-Hyon;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.50.1-50.6
    • /
    • 2016
  • Background: The aim of this study was to evaluate the clinical outcomes of implants that were placed within the maxillary sinus that has a perforated sinus membrane by the lateral window approach. Methods: We examined the medical records of the patients who had implants placed within the maxillary sinus that has a perforated sinus membrane by the lateral approach at the Department of Oral and Maxillofacial Surgery of Chonnam National University Dental Hospital from January 2009 to December 2015. There were 41 patients (male:female = 28:13). The mean age of patients was $57.2{\pm}7.2years$ at the time of operation (range, 20-76 years). The mean follow-up duration was 2.1 years (range, 0.5-5 years) after implant placement. Regarding the method of sinus elevation, only the lateral approach was included in this study. Results: Ninety-nine implants were placed in 41 patients whose sinus membranes were perforated during lateral approach. The perforated sinus membranes were repaired with a resorbable collagen membrane. Simultaneous implant placements with sinus bone grafting were performed in 37 patients, whereas delayed placements were done in four patients. The average residual bone height was $3.4{\pm}2.0mm$ in cases of simultaneous implant placement and $0.6{\pm}0.9mm$ in cases of delayed placement. Maxillary bone graft with implant placement, performed on the patients with a perforated maxillary sinus membrane did not fail, and the cumulative implant survival rate was 100%. Conclusions: In patients with perforations of the sinus mucosa, sinus elevation and implant placement are possible regardless of the location and size of membrane perforation. Repair using resorbable collagen membrane is a predictable and reliable technique.

Recovery of inferior alveolar nerve injury after bilateral sagittal split ramus osteotomy (BSSRO): a retrospective study

  • Lee, Chi-Heun;Lee, Baek-Soo;Choi, Byung-Joon;Lee, Jung-Woo;Ohe, Joo-Young;Yoo, Hee-Young;Kwon, Yong-Dae;Kwon, Yong-Dae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.25.1-25.4
    • /
    • 2016
  • Background: Bilateral sagittal split ramus osteotomy (BSSRO) is the most widely used mandibular surgical technique in orthognathic surgery and is easy to relocate the distal segments, accelerating bone repair by the large surface of bone contact. However, it can cause neurosensory dysfunction (NSD) or sensory loss by injury of the inferior alveolar nerve. The purpose of the present study was to evaluate NSD after BSSRO and modifiers at NSD recovery. Methods: In this study, NSD characteristics after BSSRO from 2009 to 2014 at the Kyung Hee University Dental Hospital were evaluated. The pattern of sensory recovery over time was also evaluated based on factors such as field of sensory dysfunction, surgical procedure, presence of pre-operative facial asymmetry, and postoperative medications. Results: Most of the patients had shown NSD immediately after orthognathic surgery. Among the 1192 sides of 596 patients, NSD was observed in 953 sides and 544 patients. Sexual predilection was shown in males (p value = 0.0062). In the asymmetric group of 132 patients, NSD was observed in 128 patients (96.97 %). In the symmetric group of 464 patients, NSD was observed in 416 patients (89.45 %); on the other hand, NSD was observed significantly higher in the asymmetric group (p = 0.025). NSD-associated factors were analyzed, and vitamin B12 may be beneficial for NSD recovery. Conclusions: There was a difference between the symmetric group and the asymmetric group in NSD recovery. Vitamin B12 can be regarded as an effective method to nerve recovery. However, a further prospective study is needed.

Quantitative localization of impacted mesiodens using panoramic and periapical radiographs

  • Choi, Hang-Moon;Han, Jin-Woo;Park, In-Woo;Baik, Jee-Seon;Seo, Hyun-Woo;Lee, Joo-Hyun;Park, Ho-Won
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate a new technique for localizing impacted mesiodens using its horizontal magnification ratio on panoramic radiographs. Materials and Methods : Location-magnification equation of a panoramic equipment was obtained from horizontal magnification ratio of a metal ball which was located variable positions from the center of image layer at interval of 2 mm. Panoramic radiographs were obtained from a skull phantom with a metal ball which was a substitute for impacted mesiodens and was embedded 10mm(Group 1), 15mm(Group 2), and 20mm(Group 3) posterior to the central incisor. Each group obtained 7 panoramic radiographs at variable positions and one periapical radiograph. Three methods were used to estimate the actual width of the incisors and the balls which were used to calculate the magnification ratio. The methods included using the actual incisor width and the calculated ball width (Method 1), using the actual incisor width and the ball widths measured on periapical radiograph (Method 2), and using the incisor and the ball widths measured on periapical radiograph (Method 3). The location of the metal ball was calculated by using the location-magnification equation. Results : The smallest difference between the calculated and the actual distance was $0.1{\pm}0.7 \;mm$ in Group 1/ Method 3. The largest difference was $-4.2{\pm}1.6 \;mm$ in Group 3/Method 2. In all groups, method 3 was the most accurate. Conclusion : Quantitative localization of impacted mesiodens is possible by using panoramic radiograph.

TENSILE BOND STRENGTH OF ALUNMINA CORE TREATED BY ION ASSISTED REACTION (이온보조반응법으로 처리한 알루미나 코아의 인장결합강도에 관한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung;Kwon, Kung-Rock;Choi, Boo-Byung;Choi, Won-Kook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.704-723
    • /
    • 2000
  • This study was undertaken to evaluate the tensile bond strength of In-Ceram alumina core treat-ed by ion assisted reaction(IAR). Ion assisted reaction is a prospective surface modification technique without damage by a keV low energy ion beam irradiation in reactive gas environments or reactive ion itself. 120 In-Ceram specimens were fabricated according to manufacturer's directions and divided into six groups by surface treatment methods of In-Ceram alumina core. SD group(control group): sandblasting SL group: sandblasting + silane treatment SC group: sandblasting + Siloc treatment IAR I group: sandblasting + Ion assisted reaction with argon ion and oxygen gas IAR II group: sandblasting + Ion assisted reaction with oxygen ion and oxygen gas IAR III group: sandblasting + Ion assisted reaction with oxygen ion only For measuring of tensile bond strength, pairs of specimens within a group were bonded with Panavia 21 resin cement using special device secured that the film thickness was $80{\mu}m$. The results of tensile strength were statistically analyzed with the SPSS release version 8.0 programs. Physical change like surface roughness of In-Ceram alumina core treated by ion assistad reaction was evaluated by Contact Angle Measurement, Scanning Electron Microscopy, Atomic Force Microscopy; chemical surface change was evaluated by X-ray Photoelectron Spectroscopy. The results as follows: 1. In tensile bond strength, there were no statistically significant differences with SC group, IAR groups and SL group except control group(P<0.05). 2. Contact angle measurement showed that wettability of In-Ceram alumina core was enhanced after IAR treatment. 3. SEM and AFM showed that surface roughness of In-Ceram alumina core was not changed after IAR treatment. 4. XPS showed that IAR treatment of In-Ceram alumina core was enabled to create a new functional layer. A keV IAR treatment of In-Ceram alumina core could enhanced tensile bond strength with resin cement. In the future, this ion assisted reaction may be used effectively in various dental materials as well as in In-Ceram to promote the bond strength to natural tooth structure.

  • PDF

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF