• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.032 seconds

Regeneration of emergence profile with soft tissue graft and wide computer aided design/computer aided mamufacturing abutments: a clinical report (연조직 이식술과 넓은 computer aided design/computer aided mamufacturing 지대주를 이용한 임플란트 고정성 보철물의 출현윤곽 재현)

  • Kim, Min-Kyung;Lee, Ji-Hun;Ahn, Seung-Geun;Kim, Kyung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.364-370
    • /
    • 2015
  • Fixed restoration using implants for patients with posterior partial edentulism is generalized technique. As patient demands increase, the functional and esthetic implant restoration to achieve similar results to lost natural teeth is becoming an important issue. It is inevitable to use customized CAD/CAM abutments rather than ready-made abutments for the creation of implant prosthesis which closely resembles natural teeth. Using CAD/CAM abutment made it possible to obtain natural emergency profiles for posterior implant prostheses, ensuring more comfortable, efficient management of oral hygiene. However, keratinized gingiva with sufficient width and height for a natural emergence profile is required to use a large diameter CAD/CAM abutment which ensures stability and esthetics of hard/soft tissue around the implants. In this case, for esthetical and functional implant zirconia prosthesis, soft tissue graft was performed and customized CAD/CAM abutments were used following ridge augmentation, sinus graft and implantation. Satisfactory results were obtained functionally and esthetically through periodic clinical evaluation, and I hereby report this case.

Evaluation of clinical outcomes of implants placed into the maxillary sinus with a perforated sinus membrane: a retrospective study

  • Kim, Gwang-Seok;Lee, Jae-Wang;Chong, Jong-Hyon;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.50.1-50.6
    • /
    • 2016
  • Background: The aim of this study was to evaluate the clinical outcomes of implants that were placed within the maxillary sinus that has a perforated sinus membrane by the lateral window approach. Methods: We examined the medical records of the patients who had implants placed within the maxillary sinus that has a perforated sinus membrane by the lateral approach at the Department of Oral and Maxillofacial Surgery of Chonnam National University Dental Hospital from January 2009 to December 2015. There were 41 patients (male:female = 28:13). The mean age of patients was $57.2{\pm}7.2years$ at the time of operation (range, 20-76 years). The mean follow-up duration was 2.1 years (range, 0.5-5 years) after implant placement. Regarding the method of sinus elevation, only the lateral approach was included in this study. Results: Ninety-nine implants were placed in 41 patients whose sinus membranes were perforated during lateral approach. The perforated sinus membranes were repaired with a resorbable collagen membrane. Simultaneous implant placements with sinus bone grafting were performed in 37 patients, whereas delayed placements were done in four patients. The average residual bone height was $3.4{\pm}2.0mm$ in cases of simultaneous implant placement and $0.6{\pm}0.9mm$ in cases of delayed placement. Maxillary bone graft with implant placement, performed on the patients with a perforated maxillary sinus membrane did not fail, and the cumulative implant survival rate was 100%. Conclusions: In patients with perforations of the sinus mucosa, sinus elevation and implant placement are possible regardless of the location and size of membrane perforation. Repair using resorbable collagen membrane is a predictable and reliable technique.

Recovery of inferior alveolar nerve injury after bilateral sagittal split ramus osteotomy (BSSRO): a retrospective study

  • Lee, Chi-Heun;Lee, Baek-Soo;Choi, Byung-Joon;Lee, Jung-Woo;Ohe, Joo-Young;Yoo, Hee-Young;Kwon, Yong-Dae;Kwon, Yong-Dae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.25.1-25.4
    • /
    • 2016
  • Background: Bilateral sagittal split ramus osteotomy (BSSRO) is the most widely used mandibular surgical technique in orthognathic surgery and is easy to relocate the distal segments, accelerating bone repair by the large surface of bone contact. However, it can cause neurosensory dysfunction (NSD) or sensory loss by injury of the inferior alveolar nerve. The purpose of the present study was to evaluate NSD after BSSRO and modifiers at NSD recovery. Methods: In this study, NSD characteristics after BSSRO from 2009 to 2014 at the Kyung Hee University Dental Hospital were evaluated. The pattern of sensory recovery over time was also evaluated based on factors such as field of sensory dysfunction, surgical procedure, presence of pre-operative facial asymmetry, and postoperative medications. Results: Most of the patients had shown NSD immediately after orthognathic surgery. Among the 1192 sides of 596 patients, NSD was observed in 953 sides and 544 patients. Sexual predilection was shown in males (p value = 0.0062). In the asymmetric group of 132 patients, NSD was observed in 128 patients (96.97 %). In the symmetric group of 464 patients, NSD was observed in 416 patients (89.45 %); on the other hand, NSD was observed significantly higher in the asymmetric group (p = 0.025). NSD-associated factors were analyzed, and vitamin B12 may be beneficial for NSD recovery. Conclusions: There was a difference between the symmetric group and the asymmetric group in NSD recovery. Vitamin B12 can be regarded as an effective method to nerve recovery. However, a further prospective study is needed.

Quantitative localization of impacted mesiodens using panoramic and periapical radiographs

  • Choi, Hang-Moon;Han, Jin-Woo;Park, In-Woo;Baik, Jee-Seon;Seo, Hyun-Woo;Lee, Joo-Hyun;Park, Ho-Won
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate a new technique for localizing impacted mesiodens using its horizontal magnification ratio on panoramic radiographs. Materials and Methods : Location-magnification equation of a panoramic equipment was obtained from horizontal magnification ratio of a metal ball which was located variable positions from the center of image layer at interval of 2 mm. Panoramic radiographs were obtained from a skull phantom with a metal ball which was a substitute for impacted mesiodens and was embedded 10mm(Group 1), 15mm(Group 2), and 20mm(Group 3) posterior to the central incisor. Each group obtained 7 panoramic radiographs at variable positions and one periapical radiograph. Three methods were used to estimate the actual width of the incisors and the balls which were used to calculate the magnification ratio. The methods included using the actual incisor width and the calculated ball width (Method 1), using the actual incisor width and the ball widths measured on periapical radiograph (Method 2), and using the incisor and the ball widths measured on periapical radiograph (Method 3). The location of the metal ball was calculated by using the location-magnification equation. Results : The smallest difference between the calculated and the actual distance was $0.1{\pm}0.7 \;mm$ in Group 1/ Method 3. The largest difference was $-4.2{\pm}1.6 \;mm$ in Group 3/Method 2. In all groups, method 3 was the most accurate. Conclusion : Quantitative localization of impacted mesiodens is possible by using panoramic radiograph.

TENSILE BOND STRENGTH OF ALUNMINA CORE TREATED BY ION ASSISTED REACTION (이온보조반응법으로 처리한 알루미나 코아의 인장결합강도에 관한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung;Kwon, Kung-Rock;Choi, Boo-Byung;Choi, Won-Kook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.704-723
    • /
    • 2000
  • This study was undertaken to evaluate the tensile bond strength of In-Ceram alumina core treat-ed by ion assisted reaction(IAR). Ion assisted reaction is a prospective surface modification technique without damage by a keV low energy ion beam irradiation in reactive gas environments or reactive ion itself. 120 In-Ceram specimens were fabricated according to manufacturer's directions and divided into six groups by surface treatment methods of In-Ceram alumina core. SD group(control group): sandblasting SL group: sandblasting + silane treatment SC group: sandblasting + Siloc treatment IAR I group: sandblasting + Ion assisted reaction with argon ion and oxygen gas IAR II group: sandblasting + Ion assisted reaction with oxygen ion and oxygen gas IAR III group: sandblasting + Ion assisted reaction with oxygen ion only For measuring of tensile bond strength, pairs of specimens within a group were bonded with Panavia 21 resin cement using special device secured that the film thickness was $80{\mu}m$. The results of tensile strength were statistically analyzed with the SPSS release version 8.0 programs. Physical change like surface roughness of In-Ceram alumina core treated by ion assistad reaction was evaluated by Contact Angle Measurement, Scanning Electron Microscopy, Atomic Force Microscopy; chemical surface change was evaluated by X-ray Photoelectron Spectroscopy. The results as follows: 1. In tensile bond strength, there were no statistically significant differences with SC group, IAR groups and SL group except control group(P<0.05). 2. Contact angle measurement showed that wettability of In-Ceram alumina core was enhanced after IAR treatment. 3. SEM and AFM showed that surface roughness of In-Ceram alumina core was not changed after IAR treatment. 4. XPS showed that IAR treatment of In-Ceram alumina core was enabled to create a new functional layer. A keV IAR treatment of In-Ceram alumina core could enhanced tensile bond strength with resin cement. In the future, this ion assisted reaction may be used effectively in various dental materials as well as in In-Ceram to promote the bond strength to natural tooth structure.

  • PDF

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

AUTOTRANSPLANTATION OF IMPACTED MAXILLARY CANINES (자가이식을 이용한 상악 매복 견치의 치료)

  • Kim, Su-Kyoung;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.481-489
    • /
    • 2007
  • Maxillary canine impaction is a frequently encountered clinical problem, and it may cause the resorption of adjacent tooth or cystic change. Treatment plan for maxillary canine impaction should be decided among extraction, orthodontic traction and autotransplantation according to several factors such as direction and position of unerupted tooth, degree of developing root apex, eruption space, exsitance of supernumerary tooth, odontoma, or cyst. Autotransplantation is a valuable alternative to extraction of impacted teeth, where surgical exposure and subsequent orthodontic realignment are difficult or impossible due to unfavorable impaction position. And its prognosis is dependent on a number of factors such as preservation of periodontal ligament, degree of root development, surgical technique, patient's age, endodontic treatment, time and type of splinting and storage medium, etc. The patients in these cases visited our dental clinic in the late permanent dentition with the chief complaint of unerupted maxillary canines. And it was thought that the spontaneous eruption guidance or orthodontic traction and alignment were difficult because of its unfavorable impacted position. Therefore, autotransplantaion and endodontic treatment were done and have been checked periodically until now.

  • PDF

The compressive fracture strength of ceromer crown by the difference of occlusal thickness (Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교)

  • Kim, Jee-Yeon;Park, Ha-Ok;Yang, Hong-So
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

The efficacy of ultrasonic irrigation technique on debris removal during root canal treatment (근관치료 시 초음파 세정 기술을 이용한 잔사 제거의 효율성)

  • Kim, Jeong-Hyeon;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2017
  • Purpose: The purpose of this study was comparing the efficacy of passive irrigation (PI) and passive ultrasonic irrigation (PUI) for ability to remove debriment of canals. Materials and Methods: Mandibular premolars were decoronated and standardized to 16 mm length. After root canal enlargement and half separating longitudinally, standardized groove of 4 mm length, 0.2 mm width and 0.5 mm depth were formed on the dentin wall of one half. Three depressions in the canal wall of the opposite half, 0.3 mm in diameter and 0.5 mm in depth, were formed. After each groove and depression was filled with dentin debris, two sections of each half were reassembled using impression putty material. In group 1 the canals were irrigated with 2.5% NaOCl by PI. In group 2 the canals were irrigated with 2.5% NaOCl by PUI. Before and after root canal irrigation, the root canal wall of the section was taken with a microscope and a digital camera as images. The amount of dentin debris remaining in grooves and depressions was assessed using a scoring system. Results: There was no significant difference between PI and PUI except for the middle 1/3 of the root canal (P = 0.004). Conclusion: At the middle 1/3 of the root canal, PUI removed more dentine debris than PI. But the removal efficiency of dentin debris is not significantly different between the PUI and PI at the apical area of root canal in mandibular premolars.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.