• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.029 seconds

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

DIFFERENTIATION OF ADULT STEM CELL DERIVED FROM BUCCAL FAT PAD INTO OSTEOBLAST (협부지방에서 성체 줄기세포의 분리와 골모 세포로의 분화)

  • Pyo, Sung-Woon;Park, Jang-Woo;Lee, Il-Kyu;Kim, Chang-Hyen
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.524-529
    • /
    • 2006
  • For the repairing of bone defect, autogenous or allogenic bone grafting remains the standard. However, these methods have numerous disadvantages including limited amount, donor site morbidity and spread of diseases. Tissue engineering technique by culturing stem cells may allow for a smart solution for this problem. Adipose tissue contains mesenchymal stem cells that can be differentiate into bone, cartilage, fat or muscle by exposing them to specific growth conditions. In this study, the authors procured the stem cell from buccal fat pad and differentiate them into osteoblast and are to examine the bone induction capacity. Buccal fat-derived cells (BFDC) were obtained from human buccal fat pad and cultured. BFDC were analyzed for presence of stem cell by immunofluorescent staining against CD-34, CD-105 and STRO-1. After BFDC were differentiated in osteogenic medium for three passages, their ability to differentiate into osteogenic pathway were checked by alkaline phosphatase (ALP) staining, Alizarin red staining and RT-PCR for osteocalcin (OC) gene expression. Immunofluorescent and biochemical assays demonstrated that BFDC might be a distinguished stem cells and mineralization was accompanied by increased activity or expression of ALP and OC. And calcium phosphate deposition was also detected in their extracelluar matrix. The current study supports the presence of stem cells within the buccal fat pad and the potential implications for human bone tissue engineering for maxillofacial reconstruction.

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS (다양한 가상 골 결함에 따른 공진 주파수의 비교 분석)

  • Kim Sang-Mi;Park Chan-Jin;Yi Yang-Jin;Chang Beom-Seok;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.487-497
    • /
    • 2005
  • Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.

IMMUNOHISTOCHEMICAL STUDY ON LYMPHOCYTE DISTRIBUTION IN ENDODONTICALLY TREATED AND UNTREATED PERIAPICAL LESIONS (근관치료전과 후의 치근단 병소에서 임파구의 분포에 관한 면역조직화학적 연구)

  • Oh, Tae-Seok;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.63-75
    • /
    • 1985
  • This study was designed to identify lymphocytes and to compare the lymphocyte distribution in endoodontically treated periapical lesions with that in endodontically untreated periapical lesions by way of immunohistochemical staining. Twenty-one human dental periapical lesions were obtained, frozened, serially sectioned to $4-5{\mu}$, and stained using the three-stage indirect immunoperoxidase technique and monoclonal antibodies for detecting the presence of B,T lymphocyte and T suppressor cell. Following results were obtained; 1. All of the examined periapical lesions had positive staining for B,T lymphocyte and T suppressor cell. 2. The concentration of T lymphocytes in 18 lesions diagnosed as periapical cyst and granuloma in both groups was greater than that of B lymphocytes and 2 periapical lesions identified as abscess in treated lesions had more positive B lymphocytes than positive T lymphocytes. 3. The average numbers of T,B lymphocytes and T suppressor cells in Endodontically treated lesions were lower than those of untreated lesions, but no statistically significant difference was noted. 4. When the distribution ratios of T lymphocytes to B lymphocytes and T suppressor cells to T lymphocytes were compared in Endodontically treated lesions by the histological aspects of the lesions and at the intervals of the duration after Endodontic treatment, a statistically significant change was not found. 5. The mean values of T lymphocytes, B lymphocytes and T suppressor cells in Endodontically treated lesions were markedly decreased in the specimens obtained at 3 month after Endodontic treatment, but no statistically significant difference was found.

  • PDF

The Effect of a Condylar Repositioning Plate on Condylar Position and Relapse in Two-Jaw Surgery

  • Jung, Gyu Sik;Kim, Taek Kyun;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Choi, Kang Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • Background Numerous condylar repositioning methods have been reported. However, most of them are 2-dimensional or are complex procedures that require a longer operation time and a highly trained surgeon. This study aims to introduce a new technique using a condylar repositioning plate and a centric relation splint to achieve a centric relationship. Methods We evaluated 387 patients who had undergone surgery for skeletal jaw deformities. During the operation, a centric relation splint, intermediate splint, final centric occlusion splint, and condylar repositioning plate along with an L-type mini-plate for LeFort I osteotomy or a bicortical screw for bilateral sagittal split ramus osteotomy were utilized for rigid fixation. The evaluation included: a physical examination to detect preoperative and postoperative temporomandibular joint dysfunction, 3-dimensional computed tomography and oblique transcranial temporomandibular joint radiography to measure 3-dimensional condylar head movement, and posteroanterior and lateral cephalometric radiography to measure the preoperative and postoperative movement of the bony segment and relapse rate. Results A 0.3% relapse rate was observed in the coronal plane, and a 2.8% relapse rate in the sagittal plane, which is indistinguishable from the dental relapse rate in orthodontic treatment. The condylar repositioning plate could not fully prevent movement of the condylar head, but the relapse rate was minimal, implying that the movement of the condylar head was within tolerable limits. Conclusions Our condylar repositioning method using a centric relation splint and miniplate in orthognathic surgery was found to be simple and effective for patients suffering from skeletal jaw deformities.

EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS. (타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향)

  • Choi, Kyoung-Kyu;Ryu, Gil-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

Quality of root canal fillings using three gutta-percha obturation techniques

  • Ho, Edith Siu Shan;Chang, Jeffrey Wen Wei;Cheung, Gary Shun Pan
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • Objectives: The goal of this study was to compare the density of gutta-percha root fillings obturated with the following techniques: cold lateral (CL) compaction, ultrasonic lateral (UL) compaction, and warm vertical (WV) compaction. Materials and Methods: Thirty-three extracted mandibular first molars, with two separate mesial canals in each, were selected. After instrumentation, the canals were stratified into three groups based on canal length and curvature, and underwent obturation with one of the techniques. No sealer was used in order to avoid masking any voids. The teeth were imaged pre- and post-obturation using micro-computed tomography. The reconstructed three-dimensional images were analyzed volumetrically to determine the amount of gutta-percha present in every 2 mm segment of the canal. P values < 0.05 were considered to indicate statistical significance. Results: The overall mean volume fraction of gutta-percha was $68.51{\pm}6.75%$ for CL, $86.56{\pm}5.00%$ for UL, and $88.91{\pm}5.16%$ for WV. Significant differences were found between CL and UL and between CL and WV (p < 0.05), but not between UL and WV (p = 0.526). The gutta-percha density of the roots treated with WV and UL increased towards the coronal aspect, but this trend was not noted in the CL group. Conclusions: WV compaction and UL compaction produced a significantly denser gutta-percha root filling than CL compaction. The density of gutta-percha was observed to increase towards the coronal aspect when the former two techniques were used.

Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

  • Charuakkra, Arnon;Prapayasatok, Sangsom;Janhom, Apirum;Pongsiriwet, Surawut;Verochana, Karune;Mahasantipiya, Phattaranant
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.143-150
    • /
    • 2011
  • Purpose : The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. Materials and Methods : One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve ($A_z$) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). Results : The mean $A_z$ values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest $A_z$ value. Conclusion : Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

  • Darsey, Drew M.;English, Jeryl D.;Kau, Chung H.;Ellis, Randy K.;Akyalcin, Sercan
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.83-88
    • /
    • 2012
  • Purpose : The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Materials and Methods : Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Results : Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Conclusion : Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro study

  • Abdinian, Mehrdad;Aminian, Maedeh;Seyyedkhamesi, Samad
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • Objectives: Foreign bodies (FBs) account for 3.8% of all pathologies of the head and neck region, and approximately one third of them are missed on initial examination. Thus, FBs represent diagnostic challenges to maxillofacial surgeons, rendering it necessary to employ an appropriate imaging modality in suspected cases. Materials and Methods: In this cross-sectional study, five different materials, including wood, metal, glass, tooth and stone, were prepared in three sizes (0.5, 1, and 2 mm) and placed in three locations (soft tissue, air-filled space and bone surface) within a sheep's head (one day after death) and scanned by panoramic radiography, cone-beam computed tomography (CBCT), and ultrasonography (US) devices. The images were reviewed, and accuracy of the detection modalities was recorded. The data were analyzed statistically using the Kruskal-Wallis, Mann-Whitney U-test, Friedman, Wilcoxon signed-rank and kappa tests (P<0.05). Results: CBCT was more accurate in detection of FBs than panoramic radiography and US (P<0.001). Metal was the most visible FB in all of modalities. US was the most accurate technique for detecting wooden materials, and CBCT was the best modality for detecting all other materials, regardless of size or location (P<0.05). The detection accuracy of US was greater in soft tissue, while both CBCT and panoramic radiography had minimal accuracy in detection of FBs in soft tissue. Conclusion: CBCT was the most accurate detection modality for all the sizes, locations and compositions of FBs, except for the wooden materials. Therefore, we recommend CBCT as the gold standard of imaging for detecting FBs in the maxillofacial region.