• Title/Summary/Keyword: Dental procedure

Search Result 925, Processing Time 0.025 seconds

Effect of 2% chlorhexidine application on microtensile bond strength of resin composite to dentin using one-step self-etch adhesives (2% 클로르헥시딘 적용이 한 단계 자가부식 접착제를 이용한 복합 레진의 상아질에 대한 미세인장 결합강도에 미치는 효과)

  • Jang, Soon-Ham;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hun;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.486-491
    • /
    • 2010
  • Objectives: This study examined the effect of 2% chlorhexidine on the ${\mu}TBS$ of a direct composite restoration using one-step self-etch adhesives on human dentin. Materials and Methods: Twenty-four extracted permanent molars were used. The teeth were assigned randomly to six groups (n = 10), according to the adhesive system and application of chlorhexidine. With or without the application of chlorhexidine, each adhesive system was applied to the dentin surface. After the bonding procedure, light-cure composite resin buildups were produced. The restored teeth were stored in distilled water at room temperature for 24 hours, and then cut and glued to the jig of the microtensile testing machine. A tensile load was applied until the specimen failed. The failure mode was examined using an operating microscope. The data was analyzed statistically using one-way ANOVA, Student's t-test (p < 0.05) and Scheffet's test. Results: Regardless of the application of chlorhexidine, the Clearfil $S^3$ Bond showed the highest ${\mu}TBS$, followed by G-Bond and Xeno V. Adhesive failure was the main failure mode of the dentin bonding agents tested with some samples showing cohesive failure. Conclusions: The application of 2% chlorhexidine did not affect the ${\mu}TBS$ of the resin composite to the dentin using a one-step self-etch adhesive.

Full mouth rehabilitation using orthodontic treatment and implants in patient with collapsed occlusion: A case report (붕괴된 교합을 가진 환자에서 교정치료와 임플란트를 이용한 전악 수복: 증례보고)

  • Ahn, Ayoung;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.439-447
    • /
    • 2019
  • The distance between the natural teeth and the implants is an important factor in preserving the periodontal tissues and esthetics. And abnormal positional displacement and tilting of the teeth during restorative procedure may require intentional root canal treatment and may affect masticatory function. This report is to present a successful full mouth rehabilitation of a patient with uneven dentition and collapsed occlusion using orthodontic and implant treatment. The patient had no symptoms or discomfort of temporomandibular joint disorder such as pain or sound. The orthodontic treatment was continued until implant provisional prosthesis delivery. And the vertical height of occlusion was elevated 2mm on anterior basis for anterior teeth protection and esthetics. After the orthodontic treatment, the implant abutments and natural teeth were finally restored with porcelain-fused-to-metal crowns and bridges. Satisfactory function and esthetic outcomes are observed after 6months of follow up.

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Periimplant bone change after alveolar ridge preservation: radiographic retrospective study (발치와 치조제 보존술 후 식립한 임플란트 주위 골 변화: 후향적 방사선학적 분석)

  • Shim, Da-Eun;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.281-290
    • /
    • 2021
  • Purpose. The aim of this study is to evaluate bone change around the implant in patients who underwent alveolar ridge preservation for implantation in the posterior teeth using radiographic data measuring changes of mesial, distal crestal bone level according to post-implantation, post-final prosthesis delivery and follow-up periods. Materials and methods. In total, 36 implants were placed in 32 patients. The mesial and distal crestal bone level of all the areas where alveolar ridge preservation was performed uses panoramic images taken post-implantation, post-final prosthesis delivery, and follow-up period each was measured and evaluated as a vertical value. The following factors were analyzed: associations between changes of crestal bone level and factors (e.g., age, sex, systemic diseases, dentist, implant location, tooth, bone type, membrane). The statistical analysis was performed using the mean, standard deviation and independent t-test, paired t-test (P < .05). Results. Analysis of crestal bone level differences between periods shows statistically significant differences (P < .05). There was no statistically significant difference when the changes of crestal bone level between post-implantation, post-final prosthesis delivery and follow-up periods were correlated with each factors. Conclusion. After alveolar ridge preservation, bone around the implant remained stable during the maintenance period without being affected by the patient and surgical factors, and alveolar ridge preservation is considered a clinically usable procedure.

Effect of milling and sintering process on integrity of zirconia prosthesis: a literature review (밀링과 소결과정이 지르코니아 보철물의 완성도에 미치는 영향에 관한 문헌고찰)

  • Lee, Kiun;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.127-137
    • /
    • 2022
  • Zirconia is fabricated through various processes. Each element in fabricating process can affect the physical properties of the definitive prosthesis. In particular, both the milling process and the sintering process can affect the final integrity of the zirconia prosthesis. Most of the milling machines adopt the ultra-precision 5-axis machining method, and the results vary depending on which milling method was used and how the milling equipment was managed. Milling blocks are selected according to cutting efficiency and aesthetic reproducibility. The sintering method can affect the grain growth and optical properties, and an accurate evaluation can be made only with additional research on the recent speed sintering procedure. Not only the sintering temperature but also the temperature holding time can affect the quality of definitive prosthesis.

Management and Knowledge for the Prevention of Infectious Diseases in the elderly (노인의 감염병 예방을 위한 관리 및 지식도)

  • Kang, Kyung-hee;Kim, Kwang Hwan;Kim, Young-Ha
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.713-720
    • /
    • 2022
  • The objective of this study is to provide the basic data for the development of educational programs for the prevention of infectious diseases targeting the elderly by researching the degree of personal hygiene practice, perceived risk of infection, and knowledge and importance of infectious diseases for the prevention of infectious diseases of the elderly. Using the structured questionnaire for a month of October in 2021, this study surveyed total 110 elderly people in their 65 or up by using the one-to-one individual interview method through the Gallup Korea. The collected data was analyzed by using the IBM SPSS Statistics 25.0 Program. In the results of analyzing the ranking by converting it into Borich's needs formula and then totaling up the degree of importance and knowledge, it was researched as the 1st place for the transmission path of infectious diseases, the 2nd place for the preventive method of infectious diseases, the 3rd place for the treatment method of infectious diseases, the 4th place for the handling procedure in case an infectious disease was doubted and confirmed, and the 5th place for the major symptoms of infectious diseases. The results of this study could contribute to the improvement of infection preventive practice through the provision of proper information to subjects, by providing the basic data for the development of educational programs for the elderly reflecting the needs of prevention and management of infectious diseases.

Explaining Variance in Children's Recall of a Stressful Experience: Influence of Cognitive and Emotional Individual Differences (스트레스적 경험에 대한 아동 기억의 신뢰성과 인지 및 정서적 개인차 특성들과의 관계)

  • Seungjin Lee
    • Korean Journal of Culture and Social Issue
    • /
    • v.19 no.3
    • /
    • pp.343-365
    • /
    • 2013
  • This study examined the effects of various individual differences on children's memory of a stressful experience. The participants for the current study were children (N=85) aged 4-9 years those who experienced a naturally occurring stressful experience from a dental procedure. There was overall negative relation between the level of stress and children's memory performance. However, more interestingly, the results of this study provided some further evidence that several cognitive (i.e., receptive language ability and working memory capacity) and emotional (i.e., children's general anxiety condition, children's self-report of pain and anxiety about the event) individual difference factors were associated with variations in children's remembering across ages. The results suggest that the relation between stress and children's memory might be impacted in part by children's various individual characteristics. Furthermore, the findings are discussed in the applied context that based on the results clinical and legal professionals can tailor interviews to best meet children's needs and capabilities, and create developmentally and individually sensitive guidelines for interviewing children in the legal system.

  • PDF

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Effect of the magnetism(neodymium magnet) on growth factor receptors of osteoblasts (희토류 자석의 자성이 골모세포 성장인자 수용체의 증가에 미치는 영향에 관한 연구)

  • Lee, Sang-Min;Lee, Sung-Bok;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • The purposes of this study were to find out the optimum intensity of magnetic field where magnetism could promote the activity of osteoblast, and to discover the possibility of clinical application in the areas of dental implants and bone grafts by confirming the effect of clinically increasing bone formation. In this experiment, we used the Neodymium magnet, which had magnetic power six times as strong as the current ones and enabled the resistances against the demagnetization up to 20 to 50 times to be minimized with the size of 1mm in sight. In order to culture cells, a specially designed device was used. It was made to adjust the distance and accordingly to control the intensity of the magnetic field, by placing the cell culture plate in the center with a magnet of 1mm long and thick installed on the both ends. Using MC3T3-E1 cell, a kind of osteoblast-like cell, we cultured, for 24 hours, not only the test group which had been cultured under the magnetic fields with different intensity of 5, 10, 50, 100, 500, and 1000 Gauss, but also the control group excluding the influences of the magnetic field. After observing the cell's form and the density of the culture medium through an inverted microscope, we made a series of proceedings needed for the immunofluoroscence staining, such as fixation, normal serum reaction, primary antibody reaction, and secondary antibody reaction. And with a fluorescence microscope, we observed those-above and compared the frequency of expression of IFG-1 receptor. To make a Western immunoblotting analysis, the cells cultured under the same condition as the above had the procedure of the lysis buffer and the acrylamide gel electrophoresis was carried out. Protein transferred into the nitrocellulose membrane and tested on the primary and the secondary antibody reactions was observed and compared. The results were as follows: When observed through an inverted microscope, the nuclear divisions of the cells under the magnetic field of 10 Gauss were the most active, and the density of the cells could be observed the most enormously. As the result of an immunofluoroscence staining of IGF-1 receptor, the expression of IFG-1 was the most frequently observed under the magnetic field of 10 Gauss. On the other hand, few differences of consideration were made between the test group cultured under the magnetic fields of 5, 500, and 1000 Gauss and the control group. In respect of the expression of IFG-1 receptor, the test group cultured under the magnetic fields of 50 and 100 Gauss were higher than the control group, and lower than that cultured under the magnetic field of 10 Gauss.(p<0.05) According to the Western immunoblotting analysis, the band of IFG-1 receptor which had 85KDa of molecular weight was the darkest. Judging from the above-mentioned results, the growth factor receptor of an osteoblast cell which was an important criterion for the bone formation was increased in maximum under the magnetic field of 10 Gauss. Moreover it was observed that the optimum intensity of magnetic field in which magnetism made the activity of the osteoblast cell increase was about 10 Gauss.

Full mouth Rehabilitation with Orthognathic Surgery in Facial Asymmetry Patient : Case Report (안면 비대칭환자의 악교정 수술을 동반한 완전구강회복)

  • Im, So-Min;Shin, Hyoung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.359-371
    • /
    • 2010
  • Facial asymmetry has been found with a higher frequency (70~84%) in skeletal class III malocclusion patients. Anticipating the poor prognosis of prosthesis due to malocclusion, occlusal stability must be obtained by orthodontic treatment. Moreover, orthodontic surgery would be needed in some severe cases for better functional and esthetic results. The orthognathic surgery is performed on one jaw or two jaw depending on the results of facial diagnosis. Genioplasty may change the vertical, horizontal, sagittal position of chin by osteotomy or augmentation using implants, also. This case is about a 24 year-old male patient who visited our clinic to solve the facial asymmetry and mandibular prognathism. Skeletal class III malocclusion, maxillary canting and menton deviation to left by 13 mm were detected. Multiple ill-fitting prostheses, unesthetic maxillary anterior prostheses, and several dental caries were found. After pre-operative orthodontic treatment, Le-Fort I osteotomy, sagittal split ramus osteotomy, genioplasty, right mandibular angle augmentation were done for the correction of jaw relation and asymmetry. By diagnostic wax-up after post-operative orthodontic treatment, maxillary full mouth rehabilitation and mandibular posterior restorations were planned out. For better result, clinical crown lengthening procedure was done on #11, 12 and implant was placed on left mandibular first molar area. The patient was satisfied with the final prostheses. Because of his high caries risk, long-term prognosis will depend on the consistent maintenance of oral hygiene and periodic follow-up.