• Title/Summary/Keyword: Dental polishing

Search Result 137, Processing Time 0.027 seconds

The Change of the Digital Skin Temperature in Dental Outpatients by Biotrainer (Biotrainer를 이용한 치과외래환자의 수지피부온도변화에 관한 연구)

  • Gi-Hong Kwon;Myung-Yun Ko
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.137-151
    • /
    • 1994
  • In order to evaluate objectively the anxiety level in dental treatment, the author used Biotrainer(BF-120R), one of the skin temperature biofeedback apparatus, to examine 68 dental outpatients on their digital skin temperature change due to routine consecutive dental procedures(oral examination, anesthetic injection, cavity preparation, fissure sealing, polishing). The subjective anxiety level change was also evaluated by visual analog scale. The obtained results were as follows : 1. The skin temperature decreased through consecutive procedures and the temperature in each procedure decreased until 60sec, and then increased on 120sec. 2. The temperature changes in Preparation and Injection were greater than those in other procedures. 3. Generally, male exhibited more change of skin temperature in all procedures than female. 4. Type II, continuously decreasing after procedure, occupied the most in all patients and yhad the lowest beseline temperature. 5. The anxiety level of before-procedure was higher than that of after-procedure and the levels in Injection and Preparation were higher than in other procedures.

  • PDF

Review on factors affecting the optical properties of dental zirconia (치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 문헌고찰)

  • Park, Chan-Ho;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.177-185
    • /
    • 2021
  • Clinical applications of translucent zirconia as well as traditional zirconia (3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) are increasing. For this reason, studies on factors affecting the optical properties of dental zirconia have been continuously reported. The optical effect of dental zirconia may vary depending on the yttria content, the thickness of the prosthesis, the sintering process, polishing, glazing and cementation in laboratory and clinical procedures. Increasing the yttria concentration can reduce the masking effect. Translucency decreases as the thickness of the restoration increases, but the required thickness may vary depending on the properties of the zirconia block. The high-speed sintering method can shorten the manufacturing time, but in some cases, the translucency of the prosthesis may decrease. In addition, the optical properties can be affected by the surface roughness of zirconia and the polishing process. The use of an appropriate colored cement can help with the masking effect of zirconia and can be useful for color matching for more esthetic results.

Observations of surface roughness of Co-Cr alloys according to grinding time of dental barrel finishing (치과용 바렐연마기의 연마시간에 따른 Co-Cr 합금의 표면거칠기 관찰)

  • Ko, Hyeon-Jeong;Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.93-98
    • /
    • 2021
  • Purpose: The aim of this study was to observe the surface roughness and surface topography of cobalt-chrome (Co-Cr) alloys with grinding time in dental barrel finishing. Methods: This study involved two types of Co-Cr alloys. Specimens were manufactured with the dimensions 10×10×2 mm. Each specimen was cast according to the manufacturer's instructions. The cast alloys were polished for 35 minutes at intervals of five minutes in an automatic barrel finishing. Specimens were imaged with a three-dimensional optical microscope to measure surface roughness. Results: BC specimens and GM specimens had the highest roughness (Ra) values in the ungrained control group, and the lowest Ra values were measured 20 minutes after grinding. Conclusion: The best conditions for grinding Co-Cr alloy using a dental barrel finishing were a weight ratio of polishing media, water, and compound of 150 g:200 g:5 g, and a rotation speed of 450 rpm. Grinding time to obtain appropriate surface roughness should be limited to 15 to 30 minutes.

Differences in view of dental hygienist and patient's scaling actual condition and disputes (치과위생사와 환자의 치석제거 실태와 분쟁에 대한 견해 차이)

  • Seong, Mi-Gyung;Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.623-633
    • /
    • 2020
  • Objectives: Since scaling has been covered by insurance, the number of patients undergoing scaling has increased. Simultaneously, legal disputes around scaling have increased. Therefore, this study was aimed at comparing the differences between the perceptions of dental hygienists and patients regarding the scaling procedure and providing dental hygienists with basic data to find ways to reduce disputes arising from these differences. Methods: A survey was conducted on 119 dental hygienists working in Busan and the South Gyeongsang Province and 110 patients who visited hospitals for scaling. Frequency analyses were performed for dental hygienists' scaling behavior and patient discomfort during scaling. The independent t-test and chi-square test were performed to compare the perceptions of dental hygienists and patients regarding the scaling procedure. Results: Polishing after scaling was performed according to 70.1% of dental hygienists but only 29.9% of patients. Oral health education was provided according to 20.4% of dental hygienists, while 79.6% of patients said that they received oral health education at the Dentiform. The scaling time was reported to be shorter by patients than by dental hygienists. Both dental hygienists and patients said that legal action was required if problems occurred during scaling, and the refund standard was that patients needed it more than dental hygienists. Conclusions: There are differences between the perceptions of dental hygienists and patients regarding scaling. Dental hygienists should identify these differences and try to prevent conflicts or disputes with patients around scaling.

Assessment of the fit of partial frame fabricated by SLS 3D printer (국부상의치의 전해연마에 따른 SLS 3D 프린터의 적합성 평가)

  • Park, Young-Dae;Kang, Wol
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.6
    • /
    • pp.1067-1075
    • /
    • 2019
  • Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

Evaluation of surface treatment methods on the bond strength of veneer ceramic to the zirconia core (지르코니아 코어와 전장용 세라믹의 결합 강도에 대한 표면 처리 방법 평가)

  • Lee, Gwang-Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.213-219
    • /
    • 2020
  • Purpose: This study aimed to identify the impact of physical surface roughing with a polishing tool onto the pre-sintering yttria-stabilized tetragonal zirconia polycrystals (TZP) core and liner treatment for chemical bonding on the bond strength of TZP core and veneering ceramic. Methods: Overall, 80 specimens were classified into two groups (non-liner, NL; and usingliner, UL ) depending on the use of liner, and these two groups were then subclassified into four groups depending on the polishing tool used. (1) Non-liner groups: NS, non-liner+stone point; NC, non-liner+carbide bur; NP, non-liner+paper cone point; NT, non-liner+silicon point. (2) Using-liner groups: US, using-liner+stone point; UC, using-liner+carbide bur; UP, usingliner+paper cone point; UT, using-liner+silicon point. The pre-sintering surface roughing values and shapes were observed, and after burning up the veneering ceramic, the shear bond strength was measured using a universal testing machine. For significance testing, a one-way analysis of variance and Tukey's multiple comparison test were conducted. An optical microscope was used to observe the fracture plane, and the following results were obtained. Results: Surface roughness NP (4.09±0.51 ㎛) represented a higher value than other groups (p<0.001). In shear bond strength, NS (35.21±1.44 MPa) of the NL group showed the highest bond strength (p<0.001). The UL group did not show a statistically significant difference between groups (p=0.612). Conclusion: Our study findings reveal that the bond strength of TZP core and veneering ceramic was improved by pre-sintering physical surface treatment than by chemical bonding with liner surface treatment.

A combined approach to non-carious cervical lesions associated with gingival recession

  • Yang, SungEun;Lee, HyeJin;Jin, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.218-224
    • /
    • 2016
  • Non-carious cervical lesions (NCCLs) with gingival recession require specific consideration on both aspects of hard and soft tissue lesion. In the restorative aspect, careful finishing and polishing of the restorations prior to mucogingival surgery is the critical factor contributing to success. Regarding surgery, assessment of the configuration of the lesion and the choice of surgical technique are important factors. The precise diagnosis and the choice of the proper treatment procedure should be made on the basis of both restorative and surgical considerations to ensure the successful treatment of NCCLs.

세치제 개발에 관한 세미나

  • The Korean Dental Association
    • The Journal of the Korean dental association
    • /
    • v.22 no.10 s.185
    • /
    • pp.855-860
    • /
    • 1984
  • 국산 세치제와 잇솔이 갖추어야 할 기본요건과 개발방향이 제시된 세미나가 지난해에 이어, 지난 7월 14~15일 양일간에 걸쳐 속리산 관광호텔에서 구강보건학계와 럭키ㆍ부광ㆍ태평양등 국내 3대 세치제 제조회사의 52명이 참석한 가운데 서울치대 예방치학교실 주최로 개최되었다. 총 13개 연제가 발표된 이번 세미나에서는, 국민 복지를 빨리 증진시키기 위하여, 기업간의 건전한 경쟁을 유도하고, 기술개발을 촉진하며, 국산품의 품질 개선, 가격인하, 국제경쟁력의 신장등, 정부의 기본방향을 재확인하는 동시에 거시적이고 원시적인 안목으로 볼때 기술개발을 위한 산학활동과 선업간의 협력은 산업발전을 통하여 국민복지 증진에 분명히 기여할 수 있음을 강조한 서울치대 김종배교수의 주제 발표와 세치제의 주요작용, 세치제의 abrasiveness 및 polishing 효과와 용어의 정의, 개인에 적합한 세치제의 선택방법, Monofluorophosphate와 plaque 및 타액의 상호작용, 세치제의 선호변인 분석, 세치제 광고문안상의 문제점, 세치제의 전망, 세치제의 전망, 세치제 개발의 제요소, 세치제의 검정 기준과 과정, 잇솔의 기본요건과 시판잇솔의 규격, 잇솔의 강모형태와 탄력성에 관한 이론적 고찰, 개인에 적합한 강모강도를 가진 잇솔의 선택방법, 「A study on the F'ion concentration of commercial dentifrices」에 대해 폭넓고 진지한 토의가 있었다. 다음은 이날 발표된 내용을 요약정리한 것이다.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFICIENCY OF A LOCAL VENTILATION SYSTEM AND THE PROTECTING FACE MASKS IN DENTAL LABORATORIES

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 1989
  • This study was performed to study the efficiency of a local ventilation system, installed in dental laboratories, and of two types of protecting face masks. The dust originating from the workpiece as well as from the wheels and stones was collected on air filters in the cutting cycle during coarse and fine grinding, and in the subsequent polishing procedures of each specific dental material. The efficiency of the ventilation system was measured on the basis of weight reduction of dust in the breathing air at a distance about 20-40 cm from workpiece. The results were as follows: 1. Use of the local ventilation system reduced the amounts of respirable dust to an average level of 21.4%, although the efficiency of the local ventilation system varied depending upon materials used. 2. Mounting a nozzle on the tube improved the efficiency of the ventilation system considerably. The efficiency of the local ventilation system also increased as the workpiece was closing to the tube inlet. 3. With or without the local ventilation system, the distance between the position of the workpiece and sampler greatly affected the dust level. 4. The face masks covering the sampler improved the efficiency of the ventilation system considerably.

  • PDF