• 제목/요약/키워드: Dental polishing

검색결과 137건 처리시간 0.022초

동대식(東大式) 건강조사표(健康調査票)에 의(依)한 치과기공사(齒科技工士)의 건강실태(健康實態)에 관한 조사(調査) 연구(硏究) (Study of Health Status of Dental Technicians by Todai Health Index)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.37-51
    • /
    • 1991
  • In order to evaluate health status of dental technicians as an individual and a group, this study was conducted with Todai Health Index Questionaire on randomly sampled 277 persons(236 males and 41 females) from Aug. 20 to Oct. 6, in 1990 obtained Following conclusions were drawn. 1. Age composition of the subjects was 136 males(57.6%) in the age of 20$\sim$29 and 28 females(68.3%) in the age of 20$\sim$24. As for working places, 215 males(91.1%) and 38 females (92.7%) were working for dental laboratories and rest of them were at clinics and hospitals. In working years, male technicians who have been working for 5$\sim$10 years amounted to 80 (33.8%) and 12 females(29.3%) were working for 1$\sim$3years. 2. Responses to psychosomatic subjective symptom complaints rated as the highest in multiple subjective symptom(males : 40.00%, females : 41.98%) and those in physical items and mental irritability(male : 24%, female : 25%) and in mental items came next in order. The rate of complaint in depression was higher in female group than in male group (p<0.05). 3. Resonses to psychosomatic subjective symptom complaints in male group were high in the age of 20$\sim$29 and in the age of 20$\sim$24 in female group. The rates of complaint were higher in multiple subjective symptom, respiratory, eye and skin(p<0.05) and digestives(p<0.01) complaints. 4. Responses to psychosomatic subjective symptom complaints were higher among persons working at dental laboratories than at other working places : dental clinics and hospitals in all the items except for respiratory, depression and aggressiveness. Rates of complaints in eye and skin showed significant difference between working places(p<0.05). 5. Those who are engaged in polishing part tended to complain more about psychosomatic subjective symptoms. 6. The higher the level of education is the more they complained the psychosomatic subjective symptoms both in male and female group. In the difference of complaint respones, male group showed high rates of complaint in depression and female group in aggressiveness(p<0.05). 7. Responses to psychosomatic complaints by the length of working service were moderate in males who were working less than 10 years, and they decreased after 10 years of service. Females showed the highest response rate in the group of 3$\sim$5 years service and the lowest response in the group of 5 years service. Male complained more in aggressiveness and female in respiratory and aggressiveness(p<0.05). 8. Responses to psychosomatic subjective symptom complaint varied according to working hours of a day both in male and female group, showing high complaint rates in multiple subjective symptom, respiratory, eye and skin, mouth and anus, digestive, mental irritability and irregular life in male group(p<0.05).

  • PDF

Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments

  • Brunot-Gohin, Celine;Duval, Jean-Luc;Verbeke, Sandra;Belanger, Kayla;Pezron, Isabelle;Kugel, Gerard;Laurent-Maquin, Dominique;Gangloff, Sophie;Egles, Christophe
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.362-371
    • /
    • 2016
  • Purpose: The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate ($LS_2$) and zirconium oxide ($ZrO_2$) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods: Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results: The best cell migration was observed on $ZrO_2$ ceramic. Cell adhesion was also drastically lower on the polished $ZrO_2$ ceramic than on both the raw and polished $LS_2$. Evaluating various surface topographies of $LS_2$ showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions: Our results demonstrate that a biomaterial, here $LS_2$, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of $LS_2$ and $ZrO_2$ ceramic showed that $LS_2$ was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.

임플란트 적용을 위한 하이드록시아파타이트·이산화티탄 표면의 생체적합성 평가 (A Biocompatibility Evaluation of Hydroxyapaite·Titania Surface for Dental Implant)

  • 강민경;배성숙
    • 치위생과학회지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2016
  • 이번 연구의 목적은 하이드록시아파타이트를 이용하여 블라스팅 처리한 뒤 양극산화 방법을 이용하여 하이드록시아파타이트와 이산화티탄이 복합된 표면을 만들고, 이에 대해 세포부착양상을 관찰하고 ALP 활성도와 칼슘 침착량을 측정함으로써 세포 분화능을 평가하여 표면의 생체적합성을 평가하는 데 있다. 이를 위해 실험을 진행한 결과 다음과 같은 결과를 얻었다. 접촉각 분석 결과, 복합처리된 HA+100과 HA+MAO 150은 유의하게 낮은 접촉각을 나타내었다(p<0.05). 세포부착 관찰 결과 연마 처리한 SM 시편에서는 납작한 모양으로 세포가 붙어있는 모습을 관찰할 수 있었으나, 표면 처리된 실험군에서는 세포의 모양이 시편을 따라 좀 더 길게 뻗어 부착된 모습을 관찰할 수 있었다. ALP 활성도 측정 결과 HA+MAO 150과 HA+MAO 200은 1, 2, 3주 모든 기간에서 가장 높은 ALP 활성도를 나타내었다(p>0.05). 칼슘양 측정 결과 HA+MAO 150 과 HA+MAO 200은 1, 2, 3주 모든 기간에서 가장 많은 칼슘양을 나타내었다(p<0.05). 따라서 하이드록시아파타이트 이산화티탄이 복합 코팅된 표면은 높은 표면에너지를 가지며 우수한 세포활성도를 나타내어 치과용 임플란트 표면으로 유용하게 사용될 수 있을 것이라고 생각된다.

유지형태에 따른 치과 인상용 트레이의 유지력에 관한 연구 (Retentive Force of Dental Impression Tray According to Retention form)

  • 최민호;신동국;김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제20권1호
    • /
    • pp.43-50
    • /
    • 2004
  • This study was performed to measure the retentive force of dental impression tray according to retention form. The 9 resin beams($30{\times}60{\times}2.5mm$) were made of visible light-curing tray resin according to the surface texture, the size of hole and the number of rim. The resin block was fabricated in width 50mm, length 30mm, heght 40mm to maintain an even hydrocolloid impression material. The retentive force between the resin beam and hydrocolloid impression material was measured by Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results obtained in this study were as follows : 1. The retentive force of the resin beam with bilateral 4 rims, 2mm holes(9group) was highest(9.18kg), and the polishing resin beam(2group) was worst(4.85kg). 2. There was no significant difference between the polished the resin beam(2group) and the contrast resin beam(1group). 3. The retentive force of the rimmed resin beam was higher than the perforated resin beam. 4. The retentive force of the 2mm perforated resin beam(4group) was higher than the 3mm perforated resin beam(3group). 5. As increasing the number of rim increased the retentive force.

치과용 지르코니아 블록의 소결온도가 기계적 특성과 미세구조에 미치는 영향 (The Effects of Sintering Temperature Influence on the Mechanical Property and Microstructure of Dental Zirconia Block)

  • 조준호;서정일;배원태
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.9-15
    • /
    • 2014
  • Purpose: Generally dental technicians clinically decide the sintering temperature of zirconia artificial teeth to match the color of the teeth. However, the sintering temperature influence the microstructure and mechanical strength of ceramic body. In this study, to evaluate the free choice of sintering temperature which leads to color the problems in zirconia false teeth, the variation of microstructure, mechanical strength, and colortone of zirconia ceramics according to the change of sintering temperature was investigated. Methods: Bar type specimens were prepared from commercial zirconia blocks by cutting and polishing into $0.8cm(L){\times}1.0cm(W){\times}4.8cm(H)$. Specimens were fired from 1,400 to $1,700^{\circ}C$ at $50^{\circ}C$ intervals and held for 1hour at highest temperature. Apparent porosity, water absorption, firing shrinkage, bulk density, bend strength, whiteness were tested. Microstructures were observed by SEM. Results: When fired above $1450^{\circ}C$, all specimens showed 0% apparent porosity and water absorption, 20% firing shrinkage, and $6.1g/cm^3$ bulk density regardless of firing temperatures. SEM photomicrographs showed grain growth of zirconia occurred above $1,600^{\circ}C$. Whiteness was also largely changed above this temperature. Maximum bend strength of 1,05MPa was obtained at $1,550^{\circ}C$. Bend strength lowered slightly above this temperature and showed $950{\ss}\acute{A}$ at $1,700^{\circ}C$. Conclusion: In order to fit the colortone of zirconia artificial teeth, arbitrary choice of firing temperature higher than $1,500^{\circ}C$, up to $1,700^{\circ}C$ did not influence the mechanical strength.

치과용 아말감의 산화환원에 관한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY ON THE OXIDATION' AND REDUCTION OF DENTAL AMALGAM)

  • 이인복;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.431-445
    • /
    • 1993
  • The purpose of this study was to observe corrosion characteristics of six dental amalgams and was to analyse corrosion products electrochemically. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by using mechanical amalgamator, the triturated mass was inserted into the cylinderical metal mold ($12{\times}10mm$) and was condensed with 160kg/$cm^2$ by using the hydrolic press. The specimen was removed from the mold and was stored at room temperature for 1 week, and was polished with amalgam polishing kit. The anodic and cathodic polarization curve was obtained by using cyclic voltammetric method with 3-electrode potentiostat in saline for each amalgam and Ag, Sn, Cu plate specimen at $37{\pm}0.5^{\circ}C$. The potential sweep range was -1.7V~0. 4V(vs SCE) in working electrode and scan rate was 50mV/s and the exposed surface area of each specimen to the electrolytic solution was $0.79cm^2$. The results were as follows. 1. In anodic-cathodic polarization curve of amalgam specimens, two anodic current rising areas and two cathodic current peaks were obtained at the low Cu amalgam(CF, CS) specimen and three anodic current rising areas and three cathodic current peaks were obtained at the high Cu amalgam (TY, DS, HV) specimen. 2. As this compared with the anodic and cathodic current peak potentials of Sn, Cu and Ag specimen, the first cathodic current peak I c was caused by the reduction of divalent tin salt, second cathodic current peak IIIc results from the reduction of quadravalent tin salt, and third cathodic current peak me results from the reduction of copper salt. 3. As reverse potential sweeping was done repeatedly, anodic current was decreased slightly in all amalgam specimens.

  • PDF

도재소부용 Ni-Cr 보철합금 개발에 관한 연구 (A Study on the Development of Porcelain Bonded Ni-Cr Dental Alloy)

  • 이규환;신명철;최부병
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권1호
    • /
    • pp.37-46
    • /
    • 1985
  • Development of a dental Ni-Cr alloy system for porcelain veneering crown and bridge was studied in this research. The principles of alloy design were a) It should not contain toxic beryllium. b) It should have low melting Point. c) It should be easily ground and polished. d) It should possess an adequate strength to resist the deformational force In the mouth. e) It should be bondable Ivith porcelain by chemically. After investigating the effect of minor elements such as boron and rare earth metals on the mechanical properties of the Ni-Cr alloy system, the compromised ideal composition for dental use was determined. The composition was l9.6%, Cr, 5.6% Mo, 3.4% Si, 1, 0% Fe, 0.01% Ti, 0.5-1.0% B, 0.2-0.6% misch metal, balance Ni. To compare the performance of experimental alloy with commercially available alloys, the properties such as strength, melting point, and bond strength were measured. The results Ivere as follows: a) Boron increases the strength of the alloy but reduces the elongation. b) Misch metal increases the strength when the boron content is low, but does not increase the strength when boron content is high. And it reduces the elongation drastically, c) Mechanical strength of the experimental alloy was not superior to commercially available Be containing alloy, but handling performance such as castability, ease of granting and polishing, and cuttability were superior to the Be containing alloy.

  • PDF

The effects of physical decontamination methods on zirconia implant surfaces: a systematic review

  • Tan, Nathan Chiang Ping;Khan, Ahsen;Antunes, Elsa;Miller, Catherine M;Sharma, Dileep
    • Journal of Periodontal and Implant Science
    • /
    • 제51권5호
    • /
    • pp.298-315
    • /
    • 2021
  • Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implantgrade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research-specifically, randomised controlled trials-would further confirm the effects of physical decontamination methods in a clinical setting.

복합레진 표면의 연마방법에 따른 표면조도 (SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS)

  • 민정범;조공철;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.138-150
    • /
    • 2007
  • 본 연구는 복합레진의 종류와 연마방법, 복합레진 연마 후 레진전색제의 적용이 복합레진의 표면조도에 미치는 영향을 알아보기 위하여 복합레진의 표면조도 측정과 FE-SEM 관찰을 통하여 상호 비교하였다. 미세입자형과 nanofill 복합레진을 이용하여 $8{\times}3{\times}2mm$의 시편을 각각 100개씩 제작하였고, 연마방법과 레진전색제의 적용 유무에 따라 20개의 군으로 분류하였다. 복합레진의 종류에 따라 Micronew를 사용한 군은 M군, Filtek Supreme을 사용한 군은 5군으로 분류한 후, 연마방법에 따라 M1 과 S1군 은 polyester strip만을 사용한 군, M2군와 S2군은 Sof-Lex disc를 사용한 군, M3군과 S3군은 Enhance disc와 polishing paste를 사용한 군, M4군과 S4군은 Astropol disc를 사용한 군, M5군과 S5군은 carbide finishing bur를 사용한 군으로 다시 분류하였다. 또한 연마 후 Biscover 레진전색제를 적용한 군은 연마방법에 따른 각 군에 B를 추가하여 M1B군-M5B군 및 S1B군-S5B군으로 분류하였다. 제작된 모든 시편은 표면조도의 측정과 주사전자 현미경 관찰을 시행하기 전에 실온의 증류수에서 24시간 동안 보관하였다. 표면조도측정기를 사용하여 각 시편의 상면과 하면 모두에서 각각 5회씩 측정하여 평균 표면조도 값을 산출하여 통계적으로 분석하였으며, 각 군에서 대표적인 시편 1개를 선택하여 FE-SEM에서 관찰하여 다음과 같은 결과를 얻었다. 1. 복합레진의 표면조도 값은 polyester strip에 의해 형성된 모든 군에서 가장 낮게 나타났고, 레진전색제를 적용한 S군을 제외한 다른 모든 군에서 finishing bur로 연마한 군이 가장 높게 나타났다 (p<0.05), FE-SEM 관찰에서 레진전색제를 적용하기 전의 표면은 polyester strip을 사용한 M1군과 S1군이 가장 평활한 표면을 나타냈고, finishing bur를 사용한 M5군과 S5군은 필러의 탈락에 의해 형성된 여러 개의 기포와 함께 울퉁불퉁한 표면을 보였다. 2. 복합레진의 종류에 따른 표면조도는 레진전색제를 적용하기 전에는 통계학적으로 차이를 나타내지 않았으나, 레진전색제를 적용한 후에는 Micronew가 Filtek Supreme보다 평활한 표면을 나타내었다 (p<0.05), 3. 레진전색제를 적용하기 전에는 복합레진의 종류와 연마방법에 따른 표면조도 간에 상호 연관성이 있었으나, 레진전색제를 적용한 후에는 복합레진의 종류와 연마방법 간에 상호 연관성이 없었다. FE-SEM관찰에서 레진전색제를 적용한 후의 표면은 모든 군에서 대체적으로 평활한 표면을 나타내었다. 4. 동일한 복합레진과 연마방법으로 처리된 군에서 레진전색제 적용 전과 후의 표면조도 값은 M1B군이 M1군보다, S1B군이 S1군보다 통계학적으로 높게 나타났으며, M4B군과 M5B군은 각각 M4군과 M5군 보다. 그리고 S5B군은 S5군 보다 통계학적으로 낮게 나타났다 (p<0.05). 본 연구를 종합하여 보면, 복합레진의 종류에 따라 표면조도의 순서는 다르게 나타났고, polyester strip 하에서 복합레진이 중합된 경우 가장 낮은 표면조도 값과 평활한 표면을 제공하였으며 전반적으로 anishing bur는 가장 높은 Ra값과 거친 표면을 제공하였다. Enhance, Astropol, carbide finishing bur로 연마한 표면은 레진전색제의 사용으로 평활한 표면을 얻을 수 있었지만, polyester strip과 Sof-Lex disc로 얻어진 표면은 레진전색제의 사용으로 표면조도의 개선이 이루어지지 않았다.

글리세린이 복합레진의 중합 후 표면경도에 미치는 영향 (Effect of glycerin on the surface hardness of composites after curing)

  • 박현희;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제36권6호
    • /
    • pp.483-489
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 글리세린의 도포가 복합레진의 중합 후 표면경도에 미치는 효과를 알아보고자 하였다. 연구 재료 및 방법: 디스크 형태의 황동 몰드에 복합레진(Z-250, 3M ESPE)을 충전 후 다음과 같이 광중합 하였다. 1군(대조군)은 복합레진 표면을 공기 중에 노출한 후 40초 동안 광조사, 2군은 표면을 Mylar strip으로 덮은 후 40초 광조사, 3군은 표면을 glycerin으로 도포 후 40초 광조사, 4군은 공기 중에 노출시켜 20초 광조사한 다음 시편 표면에 glycerin으로 도포한 후 추가로 20초 동안 광조사 하였다. 각 그룹당 20개의 시편을 준비하였고, 연마 후 또는 연마를 하지 않고 시편의 표면경도를 측정하였다. 5일 후 각 시편의 표면경도를 재 측정하였다. 데이터는 three-way ANOVA와 Tukey's post hoc test를 이용하여 분석하였다. 결과: 중합 직 후, 연마하지 않은 시편의 표면경도는 2군 > 3군 > 4군 > 1군의 순이었다. 연마한 경우 각 군 사이의 유의한 차이는 없었다. 같은 군 내에서는 5일 후 표면경도가 중합 직 후 보다 증가하였고 연마한 경우가 연마하지 않은 경우보다 더 높은 표면경도를 나타냈다. 결론: 중합 후 복합레진의 표면경도를 증가시키기 위한 가장 좋은 방법은 연마였고, 중합 전 Mylar strip의 사용이나 glycerin의 도포 역시 중합된 복합레진의 표면경도를 증가시켰다.