• Title/Summary/Keyword: Dental model

Search Result 1,366, Processing Time 0.027 seconds

Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study (상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구)

  • Park, Dong-In;Son, Ho-Jung;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

Effect of role function and personality characteristics of mentor on role stress and organization effectiveness of newly appointed dental hygienists (멘토의 역할기능과 인성특성이 초임 치과위생사의 역할 스트레스와 조직유효성에 미치는 영향)

  • Yun, Hyun-Kyung;Kim, Han-Gon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.213-221
    • /
    • 2014
  • Objectives : The purpose of this study is to examine the role function and personality characteristics of mentors on the role stress and organization effectiveness of newly-appointed dental hygienists. Methods : The data were analyzed by the frequency analysis, reliability analysis, validity analysis, and structured equation model(SEM) using AMOS 18.0. The subjects were 214 newly appointed dental hygienists in the hospitals and clinics in Daegu and Gyeongsangbuk-do Province from January to May, 2013. Results : The hypothesis model proved to be appropriate for high validity. A significant results were observed in sociopsychological function and role ambiguity, personality characteristics and role ambiguity, role ambiguity and role conflict, role ambiguity and job satisfaction, role ambiguity and organization commitment, role ambiguity and turnover intention, and career function and organization commitment. Conclusions : It is important to help manage the job-related role stress of newly appointed dental hygienist and increase organizational effectiveness by developing and applying the 'standardized role functions of mentor' which can increase the adaptability of newly appointed dental hygienists.

FACTORS AFFECTING WOMEN'S OUT-OF-POCKET COST : AN APPLICATION OF THE ANDERSEN-NEWMAN MODEL (앤더슨-뉴만 모형을 이용한 여성의 직접구강진료비 지출에 관한 연구)

  • Lee, Heung-Soo;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.689-699
    • /
    • 1996
  • The purpose of this research is to determine elements affecting the out-of-pocket cost of woman. The sample consisted of 1907 women living Iksan city. The survey was conducted by means of questionnaires. The model used in the analysis of out-of-pocket cost was the Andersen-Newman model, while the analysis techniques used were stepwise multiple regression and path analysis. The number of independent variables used in the analysis was 28 in total, ie 19 predisposing components, 6 enabling components, and 3 need components. In this study, the amount of variance by the model was 17 percent. Number of restricted activity days caused by oral disease, perceived susceptibility of dental disease, having a regular dental care, dental treatment costs, education level and income were found to have significant major effects on out-of-pocket cost. Number of restricted activity days caused by oral disease was the most important variable affecting out-of-pocket cost of woman. Also out-of-pocket cost shows larger effect due to enabling components than frequency of dental utilization.

  • PDF

A study on the accuracy evaluation of dental die models manufactured by 3D printing method (3D 인쇄방법으로 제작된 치과용 다이 모델의 정확도 평가연구)

  • Jang, Yeon
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.287-293
    • /
    • 2019
  • Purpose: To evaluate the accuracy of the 3D printed die models and to investigate its clinical applicability. Methods: Stone die models were fabricated from conventional impressions(stone die model; SDM, n=7). 3D virtual models obtained from the digital impressions were manufactured as a 3D printed die models using a 3D printer(3D printed die models;3DM, n=7). Reference model, stone die models and 3D printed die models were scanned with a reference scanner. All dies model dataset were superimposed with the reference model file by the "Best fit alignment" method using 3D analysis software. Statistical analysis was performed using the independent t-test and 2-way ANOVA (α=.05). Results: The RMS value of the 3D printed die model was significantly larger than the RMS value of the stone die model (P<.001). As a result of 2-way ANOVA, significant differences were found between the model group (P<.001) and the part (P<.001), and their interaction effects (P<.001). Conclusion: The 3D printed die model showed lower accuracy than the stone die model. Therefore, it is necessary to further improve the performance of 3D printer in order to apply the 3D printed model in prosthodontics.

Three-dimensional finite element analysis of implant-supported crown in fibula bone model

  • Park, Young-Seok;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.326-332
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis. MATERIALS AND METHODS. Two three-dimensional finite element models were created to analyze biomechanical behaviors of implant-supported crowns placed in intact mandible and fibula model. The finite element models were generated from patient's computed tomography data. The model for grafted fibula was composed of fibula block, dental implant system, and implant-supported crown. In the mandible model, same components with identical geometries with the fibula model were used except that the mandible replaced the fibula. Vertical and oblique loadings were applied on the crowns. The highest von Mises stresses were investigated and stress distributions of the two models were analyzed. RESULTS. Overall stress distributions in the two models were similar. The highest von Mises stress values were higher in the mandible model than in the fibula model. In the individual prosthodontic components there was no prominent difference between models. The stress concentrations occurred in cortical bones in both models and the effect of bicortical anchorage could be found in the fibula model. CONCLUSION. Using finite element analysis it was shown that the implant-supported crown placed in free fibula graft might function successfully in terms of biomechanical behavior.

Observation of Occlusal Relations for Production to Dental Prosthetics of Dogs (중형견 치과보철물 제작을 위한 교합관계 관찰)

  • Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.203-208
    • /
    • 2016
  • Purpose: This study introduces the production process of dog's dental prosthesis using an automated dental prosthetics technology. The occlusal interaction of dog's dental prosthesis was observed. Methods: This study was proceeded with dog's the mandibular first molar teeth. The 3D CAD designed to 3D model specimens was observed by CAD software. and The specimens designed to 3D model specimens was observed occlusal interaction by using articulator. Results: Occlusal contact point in prosthetic specimens were observed in buccal surface. and 98% of the size of the crown is the best occlusal relationship. Conclusion: Observation of occlusal relations result to 98% of the size of the crown is the best.

Approach Toward Integrated Curriculum for Dental Hygienist (치과위생사 통합교육과정을 위한 접근)

  • Hwang, Mi-Yeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.59-72
    • /
    • 2003
  • The purpose of this study was to examine what the role of denial hygienist was. The subjects were 751 dental hygienists from dental clinics, dental hospitals, general hospitals, public dental clinics and their branches throughout the nation. After a survey was conducted, the collected data were analyzed with SPSS WIN 10.0, and variance analysis and post-analysis were implemented. And Forgarty's 8th integrated model, out of 10 ones, was selected to delve into the practical role of dental hygienist in detail. The findings of this study were as follows: 1. The three age groups had a significantly different opinion on the significance of individual subjects. The dental hygienists of thirty six and over found the basic and preventive public dental care courses most important, and the 31~35 age group placed most stock in education and research. Overall, the post-analysis results showed that prevention and clinical courses were considered most vital, followed by education and fundamental courses. 2. There was a significant gap between four groups from the different work places in their view of the weight of the individual subjects. According to the post-analysis, the dental hygienists from the general hospitals, public dental clinics and their branches gave more weight to fundamental, education and research areas. Those who were with the dental clinics, dental hospitals and general hospitals put higher value on clinical course than the dental hygienists from the public dental clinics and their branches. 3. Two groups with a different career also had a different outlook on the importance of the individual subjects. The post-analysis results illustrated that the dental hygienists who had worked for three years or more put higher stress on the fundamental course than those with a less career, and the dental hygienists with a five-year or higher career attached more importance to the education and research field than those with a smaller career. 4. There was a significant difference between the three age groups in their clinical role. The post-analysis results indicated thai the younger dental hygienists were more of assistants than of professionals, as they chiefly took X-ray photograph, handled treatment materials or performed treatment-related works. Overall, handling treatment materials was most common. 5. The three groups from the different work places significantly varied in their clinical role. According to the post-analysis, those from the dental clinics and dental hospitals took more x-ray photographs, handled more treatment materials and performed more relevant works, compared to those from the general hospitals, public dental clinics and their branches. 6. The two groups with a different career differed significantly in their clinical role. The post-analysis results suggested that the dental hygienists with a less career played an assistant role more, which handled treatment materials or carried out other relevant works. 7. The fundamental courses (I) and (II), preventive class (I) and (II) and its practice course were regarded as integrated subjects that they should take 10 offer preventive treatment, which was one of the dental hygienist missions. What's needed to act as dental-care educators was the basic courses (I) and (II), dental hygiene education and its practice. Finally, integrated clinical courses (I) and (II) and clinical practice were viewed as necessary for their role performance as dental treatment collaborators.

  • PDF

Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation (치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구)

  • Park, Ju-Hee;Seol, Jeong-Hwan;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.104-115
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the image acquisition ability of intraoral scanners by analyzing the comprehensiveness of scanned images from standardized model, and to identify problems of the model. Materials and Methods: Cast models and 3D-printed models were prepared according to international standards set by ISO12836 and ANSI/ADA no. 132, which were then scanned by model scanner and two different intraoral scanners (TRIOS3 and CS3500). The image acquisition performance of the scanners was classified into three grades, and the study was repeated with varying surface conditions of the models. Results: Model scanner produced the most accurate images in all models. Meanwhile, CS3500 showed good image reproducibility for angled structures and TRIOS3 showed good image reproducibility for rounded structures. As for model ingredients, improved plaster model best reproduced scan images regardless of the type of scanner used. When limited to 3D-printed model, powdered surface condition resulted in higher image quality. Conclusion: When scanning structures beyond FOV (field of view) in standardized models (following ISO12836 and ANSI/ADA 132), lack of reference points to help distinguish different faces confuses the scanning and matching process, resulting in inaccurate display of images. These results imply the need to develop a new standard model not confined to simple pattern repetition and symmetric structure.

Accuracy evaluation of dental model scanner according to occlusal attrition type (교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가)

  • Kim, Dong-Yeon;Kim, Ji-Hwan;Lee, Beom-Il;Lee, Ju-Hee;Kim, Won-Soo;Park, Jin-Young
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.