• 제목/요약/키워드: Dental microscope

검색결과 561건 처리시간 0.02초

전부도재관용 지르코니아의 표면처리에 따른 표면특성 및 계면특성 관찰 (Interface and Surface Properties by Surface Treatment of Zirconia for All Ceramic Crown)

  • 김치영;정인성;최성민
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.137-142
    • /
    • 2013
  • Purpose: This study was to observe the surface and interfacial characteristic of Zirconia by surface treatment. And it was observed the roughness and contact angle according to processing, and the interfacial properties by surface treatment on zirconia. Methods: The oxide formation and ion diffusion between core and veneer ceramic were determined by the X-ray Dot Mapping of EPMA(Electron probe micro analyzer). The roughness was measured by 3D Digital microscope and the contact angle according to processing of zirconia was observed using distilled water on the surface. Results: The surface roughness of the specimens Z04, Z12, Z15 was measured $0.67({\pm}0.03){\mu}m$, $0.50({\pm}0.12){\mu}m$, $0.35({\pm}0.09){\mu}m$, respectively. As results of contact angle test, Z04, Z12, Z15 of specimen group without binder treatment was measured $46.79({\pm}3.17)^{\circ}$, $57.47({\pm}4.83)^{\circ}$, $56.19({\pm}2.66)^{\circ}$, respectively. but, L04, L12, L15 of specimen group without binder treatment was measured $63.84({\pm}2.20)^{\circ}$, $66.08({\pm}0.16)^{\circ}$, $65.10({\pm}1.01)^{\circ}$, respectively. Average contact angle of L15 was measured $65.10({\pm}1.01)^{\circ}$. In X-ray Dot Mapping results, thickness of binder including Al element was measured that each of L04, L12, L15 were $20{\mu}m$, $15{\mu}m$, $10{\mu}m$. Conclusion: The more rough surface increases the wettability, but the sintered exclusive binder decreases the wettability.

치아재식술 시 근관충전재로 사용된 수산화칼슘 제재의 치근단 조직 반응 및 치근 흡수의 평가 (PERIAPICAL TISSUE REACTION AND ROOT RESORPTION FOLLOWING REPLANTATION WITH DIFFERENT CALCIUM HYDROXIDE PASTES IN RAT)

  • 송상채;이승종;정일영;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.111-120
    • /
    • 2001
  • Calcium hydroxide pastes is widely used in conventional endodontics. Along with the expanded clinical use of calcium hydroxide, literatures suggest mixing calcium hydroxide with other substance. Among added substances the vehicle plays the most importance role in the overall process because it is directly related with the velocity of ionic dissociation of $Ca^{2+}$ and OH ion. In this study, we evalutated and compared periapical tissue response and root resorption after canal was filled with mixture of saline and calcium hydroxide(Junsei Chemical Co.. Japan) as a aqueous vehicle, Metapaste(Meta Co., Korea) as a viscous vehicle paste, Vitapex(Neo Dental, Japan) as a oily vehicle paste and IRM(Caulk Dentsply, USA) in replantation of rat molar. A total of 31 maxillary first molars of Sprague-Dawley female rats, 30 days old were used. The upper 1st molar was extracted and the mesiobuccal canal was filled with mixture of saline and calcium hydroxide, Metapaste, Vitapex. IRM and then replanted. Rats were sacrificed 3 weeks after replantation. the maxillae were removed. section of 4 micron were cut and stained with hematoxylin-eosin, Apical tissue response were observed under light microscope. The results were as follows: 1. Saline mixing group and Metapaste group were significant different in fibrous capsule width compared to Vitapex group and IRM group(P<0.05). 2. Saline mixing group. Metapaste group. Vitapex group and IRM group did not prevent root resorption and there were no statistical difference. 3. In saline mixing group and Metapaste group. loss of pastes were observed in all samples. From the results of our study. we observed loss of pastes in saline mixing group and Metapaste group because of water soluble property and assumed it was related to inflammation in apical area and sealing ability of material. So, we should study and develop calcium hydroxide vehicle which is easily removed and more stable and because of only 3 weeks observation we need more evaluation in long period.

  • PDF

치과용 레이저 조사가 배양 치수 섬유모세포에 미치는 영향에 관한 연구 (The EFFECTS OF DENTAL LASER ON PULP FIBROBLAST IN VITRO)

  • 정혜전;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.519-535
    • /
    • 1997
  • The responses of human pulp fibroblastic cells to Ga-As Semi-Conductor-Dens-Bio Laser (Frequency: 5 Hz~10,000 Hz Model: SD-101A RCA, U.SA)) were examined in vitro using pulp fibroblastic cells obtained from the pulp tissue of human tooth. The mitogenic effect of soft laser was assessed by measuring the MTT assay. The morphologic effect for soft laser showed under the scanning and transmission electron microscopy. The results as follows; 1. The mitogenic response of the soft laser was not observed until 4th time of radiation, while the mitogenic response at 4th time increased mitogenic effect by as much as 1.7 fold compared to the control value. 2. The mitogenic response of the soft laser on pulp fibroblast differ from the mitogenic response on other fibroblasts. 3. In scanning electron microscopic study, The microvilli of cell surface increased gradually with width and length after laser radiation, it demonstrate that development of microvilli have close connection with differentiation of cells. 4. Under the transmission electron microscope, The laser-treated cells maintained their elongated shape and a high degree of cellular polarization. The large cell body containing a well developed Golgi complex, a large number of profiles of rough endoplasmic reticulum, and great numbers of mitochondria. 5. The laser-treated cells maintained the long straight bundles of closely apposed microfilaments or individual filaments forming a cross-linked network. These findings suggest that the laser may have important roles in promotion of pulp healing and consequently may be useful for clinical application in pulp regenerative procedures.

  • PDF

제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가 (A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES)

  • 김형수;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향 (Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex)

  • 문호진;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제37권1호
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.

자가부식 프라이머의 적용시간이 법랑질 접착에 미치는 영향 (EFFECT OF THE APPLICATION TIME OF SELF-ETCHING PRIMERS ON THE BONDING OF ENAMEL)

  • 진철희;조영곤;김수미;이명선
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.224-234
    • /
    • 2008
  • 이 연구의 목적은 6종의 자가부식 프라이머 접착시스템에서 제조사에서 추천한 프라이머 적용시간과 2배의 프라이머 적용시간에 따른 법랑질에 대한 미세전단 결합강도와 전자현미경적 소견을 비교하기 위하여 시행하였다. 이 연구의 결과 법랑질에 대한 자가부식 프라이머 접착제의 결합강도는 제조사에서 추천한 프라이머의 적용시간보다 프라이머의 적용시간을 2배 증가시킨 경우 높게 나타났으며, 특히 pH가 높은 프라이머를 사용하였을 때 통계학적으로 높은 결합강도를 나타내었다. 이는 법랑질에서 pH가 높은 프라이머를 사용할 경우, 제조사에서 추천한 시간보다 더 긴 시간동안 적용하는 것이 결합강도를 증가시킬 수 있을 것으로 생각된다.

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF

압전방식초음파치석제거기의작업조건에따른치과주조용합금의삭제결손부 양상에 관한 고찰 (A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy)

  • 김영성;김수환;김원경;이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제39권4호
    • /
    • pp.385-390
    • /
    • 2009
  • Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.

The effect of two artificial salivas on the adhesion of Candida albicans to heat-polymerized acrylic resin

  • Oncul, Burcin;Karakis, Duygu;Al, Funda Dogruman
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.93-97
    • /
    • 2015
  • PURPOSE. Xerostomia can diminish the quality of life, leads to changes in normal chemical composition of saliva and oral microbiata, and increases the risk for opportunistic infections, such as Candida albicans. Various artificial salivas have been considered for patients with xerostomia. However, the knowledge on the antifungal and antiadhesive activity of artificial saliva substitutes is limited. The aim of the present study was to evaluate influence of two artificial salivas on the adhesion of Candida albicans to the polymethylmethacrylate disc specimens. MATERIALS AND METHODS. Two commercial artificial salivas (Saliva Orthana and Biotene Oral Balance Gel) were selected. 45 polymethylmethacrylate disc specimens were prepared and randomly allocated into 3 groups; Saliva Orthana, Biotene-Oral Balance gel and distilled water. Specimens were stored in the artificial saliva or in the sterile distilled water for 60 minutes at $37^{\circ}C$. Then they were exposed to yeast suspensions including Candida albicans. Yeast cells were counted using ${\times}40$ magnification under a light microscope and data were analysed. RESULTS. Analysis of data indicated statistically significant difference in adhesion of Candida albicans among all experimental groups (P=.000). Findings indicated that Saliva Orthana had higher adhesion scores than the Biotene Oral Balance gel and distilled water (P<.05). CONCLUSION. In comparison of Saliva Orthana, the use of Biotene Oral Balance Gel including lysozyme, lactoferrin and peroxidase may be an appropriate treatment method to prevent of adhesion of Candida albicans and related infections in patients with xerostomia.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.