• Title/Summary/Keyword: Dental instruments

Search Result 208, Processing Time 0.021 seconds

CHEMO-MECHANICAL REMOVAL OF CARIES IN PRIMARY MOLAR: REPORT OF 2 CASES (화학-기계적 우식 제거법을 이용한 유구치 우식의 치료: 증례보고)

  • Lee, Hyeok-Sang;Lee, Jae-Cheoun;Kim, Young-Jae;Kim, Jung-Wook;Kim, Chong-Chul;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.299-303
    • /
    • 2004
  • The conventional drilling method of caries removal makes vibration and thermal stimuli, so that children are afraid of dental treatment. Recently, various non-invasive caries removal techniques of alternatives to traditional methods are introduced and chemo-mechanical caries removal is one of them. $Carisolv^{TM}$ comprises a gel that is composed of three different amino acids and a low concentration of sodium hypochlorite and specially-designed hand instruments. This report describes two cases of dental caries treatment with $Carisolv^{TM}$. The carious dentin was eliminated with $Carisolv^{TM}$ gel with instruments and then composite resin restoration was conducted.

  • PDF

Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments

  • Gehrke, Peter;Spanos, Emmanouil;Fischer, Carsten;Storck, Helmut;Tebbel, Florian;Duddeck, Dirk
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.197-204
    • /
    • 2018
  • PURPOSE. To determine the extent of treatment traces, the roughness depth, and the quantity of titanium nitride (TiN) removed from the surface of CAD/CAM abutments after treatment with various instruments. MATERIALS AND METHODS. Twelve TiN coated CAD/CAM abutments were investigated for an in vitro study. In the test group (9), each abutment surface was subjected twice (150 g vs. 200 g pressure) to standardized treatment in a simulated prophylaxis measure with the following instruments: acrylic scaler, titanium curette, and ultrasonic scaler with steel tip. Three abutments were used as control group. Average surface roughness (Sa) and developed interfacial area ratio (Sdr) of treated and untreated surfaces were measured with a profilometer. The extent of treatment traces were analyzed by scanning electron microscopy. RESULTS. Manipulation with ultrasonic scalers resulted in a significant increase of average surface roughness (Sa, P<.05) and developed interfacial area ratio (Sdr, P<.018). Variable contact pressure did not yield any statistically significant difference on Sa-values for all instruments (P=.8). Ultrasonic treatment resulted in pronounced surface traces and partially detachment of the TiN coating. While titanium curettes caused predominantly moderate treatment traces, no traces or detectable substance removal has been determined after manipulation with acrylic curettes. CONCLUSION. Inappropriate instruments during regular plaque control may have an adverse effect on the integrity of the TiN coating of CAD/CAM abutments. To prevent defects and an increased surface roughness at the transmucosal zone of TiN abutments, only acrylic scaling instruments can be recommended for regular maintenance care.

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

A review regarding on design of engine-driven nickel-titanium file (임상가를 위한 특집 2 - 엔진구동형 니켈-티타늄 파일의 디자인에 관한 고찰)

  • Hwang, Ho-Keel
    • The Journal of the Korean dental association
    • /
    • v.51 no.10
    • /
    • pp.551-555
    • /
    • 2013
  • The purpose of this study was to give a guideline for selecting the nickel-titanium (NiTi) file by review from many studies. Since the early 1990s, several instrument systems manufactured from NiTi have been introduced into endodontic practice. The specific design characteristics vary, such as tip shape and size, cross sectional view, helix angle, and pitch space. Some of the early systems have been removed from the market or play only minor roles; others are still widely used. New designs continually are produced, but the extent to which clinical outcomes will depend on design characteristics is difficult to forecast. In this study, I have reviewed the different design characteristics in respect of the safety and efficiency. With the review from many studies, I concluded that the clinicians must be understand the specific design characteristics for selecting the ideal NiTi rotary instruments.

The Musculoskeletal Pain and Inconvenient Feeling During Hand Instruments with Mannequin and Intra-oral Cavity in Dental Hygiene Students (치위생학과 학생들의 구강 내와 마네킹에서 기구 조작시 근골격계 통증과 불편감)

  • Yoo, Jae-Hae;Ro, Hyo-Lyun;Lee, Min-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.4
    • /
    • pp.247-254
    • /
    • 2008
  • Purpose : The purpose of this study was to analyze some factors that can cause incidence of the muscle and skeletal system trouble, by which Dental Hygiene Students examine the pain and the inconvenient feeling according to kinds in manual implements and the usability in the level of manipulating and maintaining the manual implement, in the actual training of the intra oral cavity along with mannequin given the scaling practice. Methods : Targeting 18 female juniors for the department of dental hygiene, who had directly practiced oral prophylaxis for 2 years, the questionnaire research was carried out right after the mutual practice in the intra oral cavity along with mannequin. Results : It was indicated that there is no big difficulty both in intra oral cavity and mannequin in terms of manipulating implement with a method of maintaining the rightly hand fixing or of grasping the trans formative pencil and of controlling force given manipulating the implement. How to grasp a trans formative pencil was indicated to be more difficult in the intra-oral manipulation(p<.05). Pain and inconvenient-feeling level, which occur in muscle and skeletal system during practicing the scaling in mannequin, were indicated to be in order of shoulder, wrist, neck, waist, elbow, and headache. Conclusion : There was no big difference in the pain and the inconvenient feeling in muscle and skeletal system according to mannequin and intra-oral environment given manipulating tile manual implement. However, there was difference in manipulating the implement with a method of grasping transformative pencil. The pain and inconvenient feeling in muscle and skeletal system were the highest both in shoulder and wrist.

  • PDF

Ethical dilemma and related factors in some clinical dental hygienists (일부 임상치과위생사의 윤리적 딜레마와 관련 요인)

  • Kim, Yun-Jeong;Kim, Seon-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.321-327
    • /
    • 2016
  • Objectives: The purpose of the study was to evaluate the level of ethical dilemma and related factors in some clinical dental hygienists. Methods: A self-reported questionnaire was filled out by 290 clinical dental hygienists in G metropolitan city from January 5 to February 27, 2015. The instruments used for this study were the modified ethical dilemma scale developed Lee, Kim and Park. The questionnaire consisted of dental hygienists & subjects(4 items), dental hygienists & professionals(12 items), dental hygienists & partners(7 items), and medical information(31 items). The questions were measured by Likert 5 points scale. The statistical analyses include descriptive statistics, t-test and stepwise multiple regression analysis using SPSS 12.0 program. Results: Dental hygienists perceived ethical dilemma scored 3.35 and 3.24 except medical information. Professionals and partners in sub-domain of ethical dilemma by experience of ethics education and ethical conflict were high and showed statistically significant difference. The strongest predictor of dental hygienists and subjects was job satisfaction. The strongest predictor of dental hygienists and partners was adequacy of ethics education in college/university. Conclusions: The results of this study suggest that it is necessary to develop the professional dental hygiene program for the prevention of ethical dilemma in dental hygienists and to make ethics education for ethical decision making.

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using micro-computed tomography

  • Lee, Woo-Jin;Baek, Seung-Ho;Bae, Kwang-Sik
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.597-598
    • /
    • 2003
  • I. Objectives Endodontic success depends on thoroughly cleaned and completely obturated root canal system. Effective cleaning and obturation will be achieved by well shaped canal. Numerous methodologies evaluating the efficacy and safety of canal preparation has been developed and the use of micro-computed tomography(MCT) in endodontic research is one of the latest innovations. This scientific tools could overcome the inherent limitations of other methodologies, and possesses the ability to visualize morphological characteristics in a detailed and accurate manner without destruction of the tooth and offers reproducible data in all three dimensions. The purpose of this study was to determine the optimal master apical file size with less transportation and more efficiency in removing the infected dentin. For this purpose we evaluated the transportation of canal center and change of untouched area after preparation sequentially from #25 file through #40 file with 3 different instruments:Stainless steel(SS) K-type hand instruments(MANI, Japan), ProFile.04 instruments (Dentply Tulsa Dental, USA) and Lightspeed instruments(Lightspeed Technology, San Antonio, USA) using micro-computed tomography.(omitted)

  • PDF

Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

  • Kwak, Sang Won;Cheung, Gary Shun-Pan;Ha, Jung-Hong;Kim, Sung Kyo;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.

STUDY OF THE EFFECT OF ULTRASONIC INSTRUMENTATION ON BOND STRENGTH OF SEVERAL DENIAL CEMENTS (초음파 기구가 수종의 치과용 시멘트의 결합강도에 미치는 영향에 관한 연구)

  • Kim, Won-Sang;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.504-516
    • /
    • 1997
  • Ultrasonic instruments transfer electrical energy to mechanical energy resulting in vibration used for various dental treatments. If we could know the effect of ultrasonic instruments on the dental cements within the cast crown, we could take care when conducting periodontal surgery and when using the ultrasonic instrument to remove cast crown, it would be much more convenient. The purpose of this study was to compare the bond strength of several dental cements according to ultrasonic instrumentation time. In this study 4 types of cements were used to cement the specimens. they were treated with ultrasonic instrumentation for 0-5 minutes and the change in bond strength were statistically compared. The results were as followed. 1. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 0 minutes and the others and between 1 minute and 2,3,4,5 minutes (p<0.05). 2. The tensile bond strength of polycarboxylate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others and between 4 minutes and 0 minutes (p<0.05). 3. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others (p<0.05). 4. The tensile strength of resin cements showed no statistically differences according to the ultrasonic instrumentation time. In conclusion, it is considered that zinc phosphate cements is most affected by ultrasonic instrumentations and resin cement is the least affected. When using ultrasonic instruments the result avove should be used as an index.

  • PDF

Efficacy of reciprocating instruments and final irrigant activation protocols on retreatment of mesiobuccal roots of maxillary molars: a micro-CT analysis

  • Lilian Tietz;Renan Diego Furlan;Ricardo Abreu da Rosa;Marco Antonio Hungaro Duarte;Murilo Priori Alcalde;Rodrigo Ricci Vivan;Theodoro Weissheimer;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.13.1-13.13
    • /
    • 2022
  • Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials and Methods: Forty mesiobuccal roots of maxillary molars were prepared up to size 25.06 and obturated. Micro-computed tomography (micro-CT) examination #1 was performed. Teeth were then divided into 4 groups (n = 10), according to the retreatment protocol: (1) manual, (2) Reciproc Blue, (3) WaveOne Gold, and (4) X1 Blue. Micro-CT examinations #2 and #3 were performed after filling removal and repreparation, respectively. Next, all teeth were divided into 2 new groups (n = 20) according to the irrigant activation protocol: XP Clean (XP Clean size 25.02) and Flatsonic (Flatsonic ultrasonic tip). Micro-CT examination #4 was performed after irrigant activation. Statistical analysis was performed with a significance level set at 5%. Results: WaveOne Gold removed a significantly greater amount of filling material than the manual group (p < 0.05). The time to reach the WL was similar for all reciprocating systems (p > 0.05). X1 Blue was faster than the manual group (p < 0.05). Only manual group improved the filling material removal after the repreparation stage (p < 0.05). Both activation protocols significantly improved the filling material removal (p < 0.05), without differences between them (p > 0.05). Conclusions: None of the tested instruments completely removed the filling material. X1 Blue size 25.06 reached the working length in the shortest time. XP Clean and Flatsonic improved the filling material removal.