• Title/Summary/Keyword: Dental implant-abutment connection

Search Result 95, Processing Time 0.019 seconds

Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft (상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구)

  • Hwang, Hee-Sun;Jung, Ji-Hye;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: This study is to evaluate the clinical significance of implantation with simultaneous bone graft by comparing the marginal bone loss around maxillary anterior implants with or without bone graft. Materials and methods: Patients treated with implant-retained restorations on maxillary anterior region at Implant Center, Dental Hospital, Wonkwang University between June 2011 and May 2014 were included in this study. Date of implant placement, implant diameter, implant length, implant-abutment connection type and whether the bone graft was done were investigated. The patient's periapical radiographs taken immediately after implantation and at the most recent visit were compared. Marginal bone loss was measured using Emago advanced v5.6 program (Oral diagnostic systems, Amsterdam, Netherlands). Statistical analysis was done in independent t-test by using SPSS 22.0 program. Results: As a result of observing on 83 implants (without bone graft: 44, with bone graft: 39) of 52 patients for 6 - 45 months (average: 18.4 months), implants without bone graft showed $1.42{\pm}0.42mm$, implants with bone graft showed $1.28{\pm}0.45mm$ of marginal bone loss. Conclusion: In limitations of this study, implants with simultaneous bone graft had significantly less marginal bone loss than implants without bone graft.

A Literature Review on Implant Assisted Removable Partial Denture (임플란트를 이용한 국소의치에 관한 문헌고찰)

  • Lee, Ji-Hye;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • The installation of an implant in the distal extension area to assist a partial dentrue (IARPD) was used carefully in clinical situations. The purpose of this review on the IARPD is describing the concept, clinical results and guidelines of IARPD. For the review, a literature search was performed using the PubMed. The data from the literature suggest that the placement of the implants could improve function and patient satisfaction. In addition, IARPD reduced the residual ridge resorption. Longer and wider implant should be placed. Less than $15^{\circ}$ angulation may be not harmful. To prevent the loosening of the abutment, modified abutment or resilient attachment should be used. However, the connection method between the clasp retention and IARPD should be considered for long time success. Moreover, longitudinal clinical studies are required for evaluation of IARPD.

Oral rehabilitation of a patient with collapsed occlusal plane resulting from loss of posterior teeth (구치부 상실로 인해 교합 평면이 기울어진 환자에서 임플란트를 이용한 구강 회복 증례)

  • Jinwoo Han;Jae-Seung Chang;Se-Wook Pyo;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.165-173
    • /
    • 2024
  • Restoring lost teeth is very important in terms of both function and aesthetics. If tooth loss occurs in the posterior region and the loss of support is persistent, it may cause a gradual shift in the position of the mandible and a change in occlusion. This clinical case attempted to restore support for the posterior teeth with a fixed prosthesis using implants in a patient whose opposing teeth were erupted and the occlusal plane collapsed due to long-term loss of the maxillary left posterior teeth and mandibular right first molars. To correct the occlusal plane of remaining dentition, wax-up of maxillary left posterior teeth was duplicated with acrylic resin and placed on maxilla. Surgical template for implant placement were fabricated using digital technology. After the support of the posterior teeth was restored with the placement of the implant, stable occlusion with temporary restorations was observed for a sufficient time. Afterwards, monolithic zirconia prosthesis was placed on the patient to ensure functional and aesthetic improvement.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

Early Marginal Bone Loss around Submerged Implants According to the Patterns of Cover Screw Exposures (Submerged 임플란트에서 덮개나사 노출 양상에 따른 조기 변연골 상실)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.175-182
    • /
    • 2013
  • The purpose of this study was to observe and analyze the initial marginal bone resorption changes according to the patterns of cover screw exposures during healing period followed by implants installation. Total 64 fixtures(TiUniteTM, NobelBiocare, Sweden) were installed in partially edentulous jaws of 28 patients, who were selected retrospectively and were shown at least one cover screw exposure. Cover screw exposures were defined at 1 month recall. According to the patterns of exposures, groups were categorized into group 1 (No exposure), group 2 (pin-point exposure), group 3 (less than 1/2 of cover screw), group 4 (more than 1/2 of cover screw), group 5 (total exposure). Periapical radiographs were taken in purpose of changes of marginal bone level between installation and 2 month recall. Healing abutments were secured on the exposure groups at 2 month recall. Results were as follows: 1. Marginal bone resorptions were identified whenever cover screws were exposed. 2. Group 2 and 3 were shown significantly increased bone loss more than other group (P <.05). 3. Group 4 and 5 were shown significantly increased bone loss more than group 1, however, less than other groups ( P <.05). Conclusionally, cover screw exposure may cause marginal bone resorptions, therefore, early connection of healing abutment is clinically helpful.