• Title/Summary/Keyword: Dental implant surgery

Search Result 806, Processing Time 0.026 seconds

Evaluation of Efficacy of the Patient-controlled Analgesia for Implant Surgery under General Anesthesia (전신마취 하 임플란트 시술을 받은 환자에서 자가통증조절법 치료의 효용성 평가)

  • Shin, Teo-Jeon;Seo, Kwang-Suk;Park, Yun-Ki;Lee, Jung-Hoo;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.9 no.2
    • /
    • pp.98-103
    • /
    • 2009
  • Background: Despite increasing popularity of dental implants, there is limited information on the pain experience associated with the surgical implant placement under general anesthesia. The aim of this study was to assess the characteristics of patient-reported pain and efficacy of patient controlled analgesia after implant surgery under general anesthesia. Methods: Total 39 patients who underwent implant surgery under general aensthesia were enrolled. In PCA group (n=30), patients received patient controlled analgesia (fentanyl 700 mg and ketorolac 150 mg) set to basal rate 1 ml/h, bolus 1 ml, and lockout interval 10 min. In control group (n=9), patients received ketorolac 30 mg intravenously when they feel painful. We evaluated pain intensity using VAS score at the end and after 12 hr of the operation and recorded the number of bolus injection as a surrogate of rescue therapy. We compared the VAS data, the frequency of complication between two groups. Results: The self reported pain was highest at 1 hous after surgery in both groups. However, the intensity was not severe (PCA group = 5.7, control group = 5.6), and decreased gradually thereafter. Total demand bolus number was less than 6 in nearly 65% patients. And there was no significant difference in the frequency of complications such as nausea, vomiting and dizziness between both groups. Conclusions: The Pain following the surgical placement of dental implants was generally mild and gradually decreased with time. There was no difference in complications between control group and PCA group.

  • PDF

Extraction socket preservation

  • Kim, Young-Kyun;Ku, Jeong-Kui
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.435-439
    • /
    • 2020
  • Extraction socket preservation (ESP) is widely performed after tooth extraction for future implant placement. For successful outcome of implants after extractions, clinicians should be acquainted with the principles and indications of ESP. It is recommended that ESP be actively implemented in cases of esthetic areas, severe bone defects, and delayed implant placement. Dental implant placement is recommended at least 4 months after ESP.

Multiple implant therapy with multiple inductions of general anesthesia in non-compliant patients with schizophrenia: A case report

  • Choi, Yong-suk;Kim, Hyungseok;Rhee, Seung-Hyun;Ryoo, Seung-Hwa;Karm, Myong-Hwan;Seo, Kwang-Suk;Kim, Hyun Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.239-244
    • /
    • 2019
  • The effectiveness of dental implants in patients with disability, who are non-compliant during treatment, is controversial because of their poor oral health. Thus, oral health-care and management in such patients is concerning. Moreover, limited information is available on prognosis after implant placement. Herein, we describe a patient with schizophrenia who underwent dental implantation under multiple inductions of general anesthesia (5 times) and required conservative treatment and tooth extraction for multiple dental caries and retained roots because of inadequate oral health-care. Postoperatively, fracture of the prosthodontics and progression of dental caries were observed, and with 3 additional inductions of general anesthesia, conservative treatment, implant surgery, and prosthesis implantation were conducted. Postoperative 12-month follow-up since the last prosthesis implantation showed successful results. For patients with schizophrenia, multiple implantation can reduce horizontal bone loss and achieve aesthetic results compared to treatment with removable prosthodontics and could serve as an alternative treatment modality.

Consideration of computer-guided implant surgery (임플란트 가이드 수술시 고려사항)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.4-17
    • /
    • 2019
  • Nowadays, Cone-Beam CT is widely supplied in dental clinics, the distribution rate in south korea is highly ranked worldwidely. Recently, The number of Cone-Beam CTs reached 10 thousands according to national healthcare system report. Also, dental manufacturers released many kinds of In-house 3D digital printers, the distribution rate of which rises rapidly in dental clinics. Accordingly, using Cone-Beam CT data and Intraloral scan data, the application of implant guide surgery is widespread in a unit of private clinic. Through the previous articles, the latest methods of computer-guided implant surgery are reviewed, and also the considerations for precise and reliable guide surgery are summarized.

Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

  • De Oliveira, Greison Rabelo;Pozzer, Leandro;Cavalieri-Pereira, Lucas;De Moraes, Paulo Hemerson;Olate, Sergio;De Albergaria Barbosa, Jose Ricardo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.217-223
    • /
    • 2012
  • Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.

Evaluation of subjective satisfaction of dental implant patients

  • Kim, Young-Kyun;Kim, Hyun-Suk;Yi, Yang-Jin;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.130-134
    • /
    • 2014
  • Objectives: The goal of this study was to estimate the overall satisfaction level of dental implant patients and further evaluate factors influencing satisfaction. Materials and Methods: Self-administered questionnaires were mailed to patients who received dental implant therapy at Seoul National University Bundang Hospital (Seongnam, Korea) from October 2003 to April 2005. The main portion of the questionnaire was shared to evaluate the level of satisfaction with implant therapy. The questionnaires contained evaluations of influencing factors, which were classified as pain-related, service-related, and complication-related. Results: The responses from 93 patients (41 males, 52 females) with a total of 325 implants were included in the analysis, and the mean score for overall satisfaction level with implant therapy was 8.26. Female patients showed higher visual analogue scale (VAS) scores for both pain during (P=0.000) and after implant surgery (P=0.016). Male patients showed more 'negative' values for the reasonability of treatment cost (P=0.008) and the adequacy of the treatment period (P=0.022). Conclusion: The subjective satisfaction of patients was influenced by various factors, especially complication-related factors.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

Planning of Multiple Tooth Implant Placement Using the Standardized Data in Teeth Size and Position (표준 치아 크기 및 배열 정보를 이용한 다중 치아 임플란트 식립계획 방안)

  • Park, Hyung-Wook;Park, Sang-Jin;Park, Hyungjun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.348-356
    • /
    • 2015
  • It is important to devise methods for assisting dentists to consistently determine implant positions and directions and to accurately perform drilling tasks during dental implant surgery. In this paper, we propose a novel approach to tooth implant placement planning which deals with the determination of the positions and directions of multiple implant fixtures for a set of missing mandibular teeth and suggests the selection of the sizes and types of the implant fixtures. We combine Korean standard data in the sizes and positions of human teeth with the patient specific 3D models of mandibular jawbones, nerve curves, and neighboring teeth around the missing teeth in order to determine the positions and directions of the implant fixtures for the missing teeth. Using the geometric and spatial information of the jawbones, the teeth and the implant fixtures, we can construct the 3D models of surgical guide stents which are crucial to perform drilling tasks with ease and accuracy. Adopted in 3D simulation of dental implant placement, the approach can provide surgeon students with good educational contents. We also expect that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

Disappearance of a dental implant after migration into the maxillary sinus: an unusual case

  • Damlar, Ibrahim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.278-280
    • /
    • 2015
  • Migration of dental implants into the maxillary sinus is uncommon. However, poor bone quality and quantity in the posterior maxilla can increase the potential for this complication to arise during implant placement procedures. The aim of this report is to present a dental implant that migrated into the maxillary sinus and disappeared. A 53-year-old male patient was referred to us by his dentist after a dental implant migrated into his maxillary sinus. The displaced implant was discovered on a panoramic radiograph taken five days before his referral. Using computed tomography, we determined that the displaced dental implant was not in the antrum. There was also no sign of oroantral fistula. Because of the small size of the displaced implant, we think that the implant may have left the maxillary sinus via the ostium.

Planning of Dental Implant Placement Using 3D Geometric Processing and Finite Element Analysis (3차원 기하 처리와 유한요소 분석을 이용한 치아 임플란트 식립 계획 수립)

  • Park, Hyung-Wook;Park, Chul-Woo;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.4
    • /
    • pp.253-261
    • /
    • 2012
  • In order to make dental implant surgery successful, it is important to perform proper planning for dental implant placement. In this paper, we propose a decent approach to dental implant placement planning based on geometric processing of 3D models of jawbones, a nerve curve and neighboring teeth around a missing tooth. Basically, the minimum enclosing cylinders of the neighboring teeth around the missing tooth are properly used to determine the position and direction of the implant placement. The position is computed according to the radii of the cylinders and the center points of their top faces. The direction is computed by the weighted average of the axes of the cylinders. For a cylinder whose axis passes the position along the direction, its largest radius and longest length are estimated such that it does not interfere with the neighboring teeth and the nerve curve, and they are used to select the size and type of an implant fixture. From the geometric and spatial information of the jawbones, the teeth and the fixture, we can construct the 3D model of a surgical guide stent which is crucial to perform the drilling operation with ease and accuracy. We have shown the validity of the proposed approach by performing the finite element analysis of the influence of implant placement on bone stress distribution. Adopted in 3D simulation of dental implant placement, the approach can be used to provide dental students with good educational contents. It is also expected that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.