• Title/Summary/Keyword: Dental implant surgery

Search Result 806, Processing Time 0.026 seconds

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

The Relationship between Dental Treatment and Temporomandibular Disorder (치과치료와 턱관절장애의 연관성에 관한 연구)

  • Kim, Yeong-Gyun;Lee, Yong-In
    • The Journal of the Korean dental association
    • /
    • v.46 no.5
    • /
    • pp.308-314
    • /
    • 2008
  • The risk of temporomandibular joint disorder (TMD) can be increased during dental treatment due to excessive mouth opening and change of occlusion. The aim of this study is to find the relationship between dental treatment and TMD in the patients who developed TMD after dental treatment. The subjects of this study were 21 patients, who developed TMD after dental treatment and were treated with active TMD therapy in Seoul National University Bundang Hospital from June 2003 to February 2007. The subjects were examined with preceding dental treatment, symptom, diagnosis, treatment method of TMD and prognosis of TMD. The obtained results were as follows. 1. Preceding dental treatments were : Implant treatment, 14 cases ; Tooth extraction, 3 cases and others. 2. TMD symptoms were : pain on TMJ, 12cases : Sound on TMJ, 3cases ; Mouth opening limitation, Headache and others. 3. Diagnoses of TMD were : Synovitis and/or capsulitis, 10 cases ; 8 cases of Internal derangement and others. 4. Most TMD were treated by stabilization splint. 5. Prognoses of TMD were : Improvement, 6cases ; sustained 11 cases. In conclusion, the risk of TMD is increased during implant treatment. Prognoses of TMD after dental treatment were bad. It might be that these patients were non-cooperative and have distrust of dental treatment. Because the overloading on TMJ is possible in dental treatment of patients with underlying TMD, prior explanation and knowledge TMJ treatment are very important in these cases.

  • PDF

Periosteum-attached Autogenous Block Bone Graft with Simultaneous Implant Placement on the Anterior Maxilla: A Case Report

  • Seung-Hyun Park;Jongseung Kim;Ui-Won Jung;Jae-Kook Cha
    • Journal of Korean Dental Science
    • /
    • v.17 no.2
    • /
    • pp.64-74
    • /
    • 2024
  • This case report presents the long-term radiographic outcomes of a novel approach for simultaneous lateral augmentation and implant surgery. A 60-year-old male patient who required tooth extraction of the maxillary central and lateral incisors due to trauma visited the clinic. After tooth extraction, severe horizontal and vertical deficiencies occurred owing to atrophy of the alveolar ridge, and a simultaneous guided bone regeneration (GBR) procedure was planned along with the installation of two implants. In the present case, a modification of the conventional 'sandwich technique' was used by placing the mixture of autogenous bone chips and xenografts at the outermost layer to maximize the osteogenic potential at the coronal part of augmentation while applying solely xenografts at the inner layer. To enhance volumetric stability, an autogenous block of periosteum harvested from the maxillary tuberosity was incorporated between the two layers. Cone-beam computed tomography was performed at baseline and 3 years after the surgery to compare radiographic outcomes. Dehiscence after fixture installation was successfully observed at the re-entry of the surgery site. Three years after the surgery, average horizontal bone gains of 6.11 mm and 4.12 mm were observed in the maxillary central and lateral incisor areas, respectively. Healthy peri-implant mucosa and well maintained marginal bone levels were observed 8 years after the surgery, meeting the criteria for implant success. The findings of this case suggest that a substantial amount of horizontal bone gain can be obtained with a layered approach using autogenous bone materials and xenografts, highlighting the advantages of incorporating autogenous blocks into the simultaneous GBR procedure.

Evaluation of Crestal Bone Resorption of the TiUnite(R) Anodized Implant System

  • Kim, Young-Kyun;Ahn, Min-Seok;Lee, Yang-Jin;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.4-9
    • /
    • 2008
  • Purpose : This study sought to examine the aspects of crestal bone resorption and to evaluate the clinical outcomes of the TiUnite$^{(R)}$ (Nobel Biocare, Sweden) anodized implant system. Materials and Methods : Among the 67 patients (211 fixtures) who were treated using TiUnite(r) implants at Seoul National University Bundang Hospital between March 2004 and January 2007, 26 (91 fixtures) were considered in this study. Initial and secondary stabilities were measured using Periotest$^{(R)}$ and Ostell(tm) Mentor. The radiographic evaluation of crestal bone resorption was carried out by measuring the change in crestal bone level at the time of surgery compared to that 1 year after loading. Panoramic radiograph and periapical radiograph were used. Based on the radiographic findings, the shapes of crestal bone resorption were classified. Results : The average amount of crestal bone resorption after 1 year of functional implant loading was 0.30 mm. There was no saucerization in 40 implant fixtures (43.9%), although more than 1 thread were exposed in 51 implant fixtures (56.6%). The success rate of the implants was 94.5%, and the survival rate was 100%. Conclusions : Good clinical outcomes and minor crestal bone resorption were noted in this study. Saucerization for the establishment of biological width was not a general finding in the TiUnite$^{(R)}$ anodized implant system.

  • PDF

Applications of Non-Thermal Atmospheric Pressure Plasma in Dentistry (상온 대기압 플라즈마의 치의학적 응용)

  • Uhm, Soo-Hyuk;Kwon, Jae-Sung;Lee, Eun-Jung;Lee, Jung-Hwan;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.783-794
    • /
    • 2014
  • Since the introduction of non-thermal atmospheric pressure plasma in the field of the dentistry, numerous applications have been investigated. Especially with its advantages over existing vacuum plasma in terms of portability, low cost, and non-thermal damage, it can be directly applied in the oral cavity, giving number of potentials for dental application. First, possible application of non-thermal atmospheric pressure plasma in the field of dentistry is relation to dental caries and periodontal diseases. Teeth and alveolar bones are one of the strongest bony structures in our body, but it cannot be regenerated when they are damaged by dental caries or periodontal disease. Hence many studies to prevent such diseases have been carried out, though no perfect solution has been found yet. With recent studies of modifying surfaces through non-thermal atmospheric pressure application that can prevent attachment of bacteria, or studies on bactericidal effects of non-thermal atmospheric pressure plasma can be applied here to prevent oral pathogen and 'biofilm' attachment to the surface of teeth or directly eliminate the dental caries/periodontal disease causing germs. Secondly, non-thermal atmospheric pressure application will be useful on the surface of dental implant. It is well known that the success of dental implant surgery depends on the process known as 'osseointegration' that result from osteoblast attachment, proliferation and differentiation. As the application of non-thermal atmospheric pressure plasma on the surface of dental implant just before its introduction by the chair-side of dental surgery. Despite its long history, the generation of non-thermal atmospheric pressure plasma has been greatly increased with its application in dentistry.

THE USEFULNESS OF IMMEDIATE IMPLANTATION USING $BIO-OSS^{(R)}$ AND $BIO-GIDE^{(R)}$. IN $ITI^{(R)}$. IMPLANT SYSTEM ($ITI^{(R)}$ implant system에 있어서 $Bio-Oss^{(R)}$$Bio-Gide^{(R)}$를 이용한 발치 후 즉시 임플란트의 유용성)

  • Park, Kwan-Soo;Yoon, Kyu-Ho;Cheong, Jeong-Kwon;Shin, Jae-Myung;Hong, Sung-Chul;Jeon, In-Seong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.58-67
    • /
    • 2006
  • In the recent studies, many authors have reported that the success rate of immediate implantation has no difference compared to conventional staged implantation. Although the immediate implantation has many advantages over conventional approach, many clinicians don't seem to practice because they think that most of the extraction sockets will have some bony gab with defects around implant and that this situation makes the result of immediate implantation unpredictable. We clinically analyzed 23 implanted sites of 18 patients treated with immediate implantation in our hospital from September 2003 to January 2004. The $ITI^{(R)}$. dental implant system was used and GBR procedure with $Bio-Oss^{(R)}$. and $Bio-Gide^{(R)}$. was done simultaneously. The pre & post-op. measurements were recorded such as alveolar crest-adjacent tooth CEJ distance, gingival crest-adjacent tooth CEJ distance, existence of periapical lesion, vertical defect around the extraction socket, horizontal defect around the extraction socket, probing depth, radiologic change of alveolar crest height. We report a positive outcome about immediate implantation with review of literatures.

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems (Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교)

  • Oh, Jun-Ho;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

What is the effect of initial implant position on the crestal bone level in flap and flapless technique during healing period?

  • Al-Juboori, Mohammed Jasim;Ab Rahman, Shaifulizan;Hassan, Akram;Ismail, Ikmal Hisham Bin;Tawfiq, Omar Farouq
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: The level of the implant above the marginal bone and flap design have an effect on the bone resorption during the healing period. The aim of this study is to detect the relationship between the level of the implant at the implant placement and the bone level at the healing period in the mesial and distal side of implants placed with flapless (FL) and full-thickness flap (FT) methods. Methods: Twenty-two nonsubmerged implants were placed with the FL and FT technique. Periapical radiographs were taken of the patient at implant placement, and at 6 and 12 weeks. By using computer software, bone level measurements were taken from the shoulder of the healing cap to the first bone implant contact in the mesial and distal side of the implant surface. Results: At 6 weeks, the correlation between the crestal bone level at the implant placement and crestal bone level of the FT mesially was significant (Pearson correlation coefficient=0.675, P<0.023). At 12 weeks, in the FT mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.297, P<0.346). At 6 weeks in the FT distally, the correlation was nonsignificant (Pearson correlation coefficient=0.512, P<0.107). At 12 weeks in the FT distally, the correlation was significant (Spearman correlation coefficient=0.730, P<0.011). At 6 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.083, P<0.809). At 12 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient= 0.062, P<0.856). At 6 weeks in the FL distally, the correlation was nonsignificant (Spearman correlation coefficient=0.197, P<0.562). At 12 weeks in the FL distally, the correlation was significant (Pearson correlation coefficient=0.692, P<0.018). Conclusions: A larger sample size is recommended to verify the conclusions in this preliminary study. The bone level during the healing period in the FT was more positively correlated with the implant level at implant placement than in the FL.