• Title/Summary/Keyword: Dental implant surgery

Search Result 806, Processing Time 0.022 seconds

CLINICAL USAGES OF RAMAL AUTOGENOUS BONE GRAFTS IN DENTAL IMPLANT SURGERY (임플란트 식립 수술시 하악지 자가골이식술의 임상적 활용)

  • Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.266-275
    • /
    • 2008
  • Dental endosseous implants require sufficient alveolar bone volume and quality for complete bone coverage and initial stability. But, atrophy or resorption of alveolar bone height and width according to patient's age and period of tooth loss can prevent ideal implant placement. Bone graft procedure has been proposed before or simultaneously with the placement of dental implants in patients with insufficient alveolar bone volume. While allografts, xenografts, and alloplastic bone grafts have been proposed and studied for alveolar ridge augmentation, the use of autogenous bone grafts represents the 'gold standard' for bone augmentation procedures. Conventional bone grafts are usually harvested from distant sites such as the ilium or ribs. Recently there is a growing use of intraoral bone grafts from intraoral donor sites such as mandibular symphysis, mandibular ramus and maxillary tuberosity. We recommend that the mandibular ramus is a safe autogenous bone graft donor site for bone harvesting with low morbidity. We report various effective autogenous bone graft procedures from mandibular ramus for the implant placement on various atrophic alveolar ridges.

Frequency and time of actual duties of some dental hygienists (일부지역 치과위생사의 실제 업무의 빈도와 소요시간)

  • Hwang, Soo-Jeong;Han, Yang-Keum
    • Journal of Korean Academy of Dental Administration
    • /
    • v.7 no.1
    • /
    • pp.10-20
    • /
    • 2019
  • Korean dental hygienists perform more tasks in dental clinics than are described in the law. The purpose of this study was to investigate the actual work of Korean dental hygienists in dental clinics using an observational study design. Two dental hygienists observed and recorded the work performed in 1 day from the time of commencement to the time of leaving work by 18 dental hygienists working in the dental clinic in a single area. Data management, prevention of infection, counseling, calculus removal, radiography, assistance of fixed orthodontic treatment, assistance of fixed prosthetic treatment, and preparation for implant surgery were recorded. Among the tasks that take more than 1 min, the most time-consuming tasks were document management, infection control, consultation, calculus removal, preparation for implant surgery, assistance of orthodontic treatment, and assistance of fixed prosthetic treatment. Korean dental hygienists are performing various tasks, such as infection control, dental hospital/clinic management, oral disease prevention, and dental treatment assistants.

A Comparison of the Appearance in Implant Success according to Membrane Type during GBR(Guided Bone Regeneration) (골유도 재생술식(GBR)시 차단막 종류에 따른 임플란트 결과 비교)

  • Lee, Sunmi;Kim, Jiyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • Purpose : The aim was to compare the implant success rate according to membrane type through a clinical case of patients, who used bio-resorbable membrane and non-resorbable membrane. Methods : A survey was conducted targeting patients with the use of bio-resorbable membrane and non-resorbable membrane who visited H dental clinic in Busan for implant surgery and bone graft for 1 year from May 2010 to May 2011. A chart was made and surveyed for 100 people with non-resorbable membrane and for 75 people with bio-resorbable membrane. Results were compared. Results : 1. As for the measurement value of Periotest M${(R)}$, the value of -8~0 was measured with 92% in case of surgery by using non-resorbable membrane. The value of +1~+9 was measured with 8.0%. In case of surgery by using bio-resorbable membrane, Peiotest M(R) was measured with 78.7% as for the value of -8~0 and 16(21.3%) as for the value of +1~+9. In light of this, a case of using non-resorbable membrane was indicated to be higher(p=0.021) in success rate than a case of using bio-resorbable membrane. 2. As a result of periodontal conditions, namely, bleeding(p=0.914), swelling(p=0.500), inflammation(p=0.074), pain(p=0.571), and itch appearance(p=0.475) according to membrane type, all were insignificant. Conclusions : A case of using non-resorbable membrane is considered to be likely to be more effective than using bio-resorbable membrane during GBR(Guided Bone Regeneration) with the use of membrane in implant surgery.

Improvement of biohistological response of facial implant materials by tantalum surface treatment

  • Bakri, Mohammed Mousa;Lee, Sung Ho;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.52.1-52.8
    • /
    • 2019
  • Background: A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods: Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results: The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion: Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.

Fractures of implant fixtures: a retrospective clinical study

  • Yu, Han-Chang;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.13.1-13.6
    • /
    • 2020
  • Background: The aim of this study was to evaluate the factors that may affect implant fixture fractures. Methods: Patients who experienced implant fixture removal at Seoul National University Bundang Hospital from 2007 to 2015 due to implant fixture fracture were included. Implant/crown ratio, time of implant fracture, clinical symptoms before implant fracture, treatment of fractured implants, and the success and survival rate of the replaced implants were evaluated retrospectively. Results: Thirteen implants were fractured in 12 patients. Patient mean age at the time of fracture was 59.3 years. Of the 13 implants, 7 implants were placed at our hospital, and 6 were placed at a local clinic. The mean crown/implant ratio was 0.83:1. The clinical symptoms before fracture were screw loosening in five implants, marginal bone loss in five implants, and the presence of peri-implant diseases in five implants. All the fractured implants were removed, and 12 out of the 13 sites were re-implanted. Parafunctions were observed in two patients: one with bruxism and one with attrition due to a strong chewing habit. Conclusions: Several clinical symptoms before the fracture of an implant can predict implant fixture failure. Therefore, if these clinical symptoms are observed, appropriate treatments can be taken before more serious complications result.

Survival rate of Astra Tech implants with maxillary sinus lift

  • Yoon, Wook-Jae;Jeong, Kyung-In;You, Jae-Seek;Oh, Ji-Su;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.17-20
    • /
    • 2014
  • Objectives: The aim of this study was to retrospectively evaluate the clinical survival rate of Astra Tech implants in the maxillary molar region performed with sinus lift and bone graft. Materials and Methods: Ninety-nine Astra Tech implants (Osseospeed) placed in the maxillary molar region using sinus lift from September 2009 to February 2012 were selected with a minimum follow-up period of 1 year. The height of alveolar bone, sinus approach technique, bone material and implant survival rate were evaluated. Results: Of the 99 implants, the survival rate was 90.9%; 8 implants failed within 1 year after implant placement, and 1 implant failed 1 year after implant loading. All failed implants were placed with sinus lift simultaneously. The average height of alveolar bone before implant placement was 6.9 mm, while the height of alveolar bone of failed implants was 2.1 mm, on average. Conclusion: Astra Tech implants placed in the maxillary molar region had generally good survival rates, but the relationship between reduced pre-implant alveolar bone height and implant failure requires further attention.

Evaluation of Stability of Double Threaded Implant - Clinical Assessment During Osseointegration; Part II (이중나사산 임플란트의 안정성에 대한 평가 - 골유착 기간 중의 임상적 평가; PART II)

  • Heo, Jin-Ho;Kim, Si-Yeob;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.337-358
    • /
    • 2007
  • Purpose This study was performed to evaluate the stability of dual thread implant using resonance frequency analysis in human. Materials and methods Fifty-five patients(32 males and 23 females) with a mean age of 50 years and 1 month who were treated during March, 2005 to July, 2007 in Pusan National University hospital. Totally 145 dual thread Implants were installed and initial stability was measured by Osstell $Mentor^{TM}$. After 3-6 Months, secondary stability was measured at the time of second surgery or before prosthetic treatment. Results At the time of 1st surgery, average ISQ value was $75.12{\pm}12.06$. Only 1 implant was failed during the healing period. Before prosthetic treatment, ISQ values were measured and its mean value was $80.94{\pm}6.12$. Conclusion These results suggest that the increased stability of the implant verifies the clinical relevance of double thread implant.

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam;Pil-Jong Kim;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee;Young Ku;In-Chul Rhyu;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.53-62
    • /
    • 2024
  • Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

Immediately loaded dental implants with fixed prostheses using a computer-guided surgery in a mental retardation patient: a case report (정신지체장애환자에서 Computer-Guided Surgery를 이용한 임플란트 식립 및 즉시 보철물 장착: 증례보고)

  • Han, Se-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.246-252
    • /
    • 2014
  • $Br{\aa}nemark^{\prime}s$ original protocol required 4 to 6 months for implant osseointegration before placement of the definitive prosthesis. Although this approach gave very predictable results, it had certain drawbacks. The main disadvantages of this approach were prolonged treatment time, two surgical procedures, placement of a removable prosthesis that required modifications during the course of treatment, and a greater number of appointments. Immediate implant loading is a viable treatment method for selected cases. One of the greatest advantages of this method is the virtual surgery, which precedes the actual clinical treatment and eliminates any need for last minute decisions. The actual surgery time is decreased, since all steps are predetermined. These advantages aren't only more useful for normal patients but also for the mental retardation patients whose cooperation is difficult. This article presents a clinical approach made possible due to the guided implant surgery and CAD/CAM technique.