• 제목/요약/키워드: Dental etching

검색결과 148건 처리시간 0.026초

표면 처리방법에 따른 복합레진의 미세누출에 관한 실험적 연구 (A STUDY ON MICROLEAKAGE OF COMPOSITE RESIN AFTER SURFACE TREATMENT)

  • 이창우;김정욱;이상훈
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.103-115
    • /
    • 1998
  • Adhesion of composite resin to tooth structure has been of tremendous signgicance in clinical dentistry. Due to the lack of adhesion between composite restorative resins and enamel and dentin, microleakage occurs at the tooth/restoration interface. This may lead to discoloration, secondary caries, marginal breakdown, postoperative sensitivity, and even pulpal pathology. According to extensive use of composite resin, every effort on improving bonding strength and reducing microleakage between a tooth and composite resin has been continued. This study was conducted to determine the difference in microleakage in enamel and dentin treated with air-abrasion, acid etching and combination when restored with composite resin. Class V cavities were prepared on 30 premolars. The specimens were divided into following groups. group 1:air-abrasion+Scotchbond Multi-purpose group 4 :air-abrasion+All-Bond 2 group 2:acid etching+Scotchbond Multi-purpose group 5 :acid etching+All-Bond 2 group 3:combination+Scotchbond Multi-purpose group 6 :combination+All-Bond 2 #combination:air-abrasion + acid etching The specimens were filled with Z-100 after application of Scotchbond Multi-purpose and All-Bond 2. Thermocycling was conducted by alternately dipping the specimens in $5^{\circ}C$ and $55^{\circ}C$ water for 30 seconds 500 times. 1% methylene blue was applied and the specimens were left for 24 hours at $37^{\circ}C$. After washing out the dye, the tooth was sectioned buccolingually along the axis. The sectioned surface was observed with stereoscope for dye penetration. The author has measured the microleakage in teeth prepared with air-abrasion, acid ethching and combination to study the difference in microleakage following different methods of tooth surface treatment and has come to following results. 1. In comparing microleakage between groups, group 1 and 4 showed statistically significant difference from group 2, 3, 5 and 6(p<0.05). There was no significant difference among group 2, 3, 5, 6(p>0.05) nor between group 1 and 4(p>0.05). 2. In comparing microleakage among tooth surface treatment methods, Air-abrasion group showed significantly more microleakage than acid etching group and combination(airabrasion + acid etching) group(p<0.05). Combination(acid etching+air-abrasion)group tended to show lesser microleakage than acid etching group, but this was not statistically significant(p>0.05). 3. In comparing microleakage between bonding agents, there was no statistically significant difference between Scotch bond Multi-purpose and All-Bond 2(p>0.05).

  • PDF

치과용 비귀금속합금의 식각표면에 대한 주사전자현미경적 연구 (Scanning Electron Micrographic Study on the Etched Surface of Base Metal Alloys for Dental Restorations)

  • 정헌영;이선형
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.83-95
    • /
    • 1985
  • The purpose of this study was to evaluate microstructures on the etched surface of 11 base metal alloys for dental restorations and to observe the relationship between the etching pattern and beryllium. For this purpose, the following experiments were done; 11 base metal alloys were etched in (1) 10% $H_2SO_4$, (2) 10% $H_2SO_4$, 9 parts+methanol 1 part (3) Conc. $HNO_3$ 25%+glacial acetic acid 25%+$H_2O$ 50% (4) Conc. $HNO_3$ 5% (5) 2% glacial acetic acid added to Conc. $HNO_3$ 1% solution, with their etching conditions varied. Etched surface of alloys were examined under the scanning electron microscope. Results were as follows; 1. Almost all of Ni-Cr-Be alloys showed gooed etchd surface in $H_2SO_4$, solution, while some of those alloys which contains no beryllium showed good etched surface in $HNO_3$ solution. 2. Main components of etching solution can vary etching pattern of alloys. 3. Gamma prime phase relief, which can be found in all Ni-Cr-Be alloys, can't be found in any alloy that contains no beryllium.

  • PDF

복합레진의 수리 시 표면처리가 결합강도에 미치는 영향 (EFFECT OF SURFACE TREATMENTS ON THE REPAIR BOND STRENGTH OF COMPOSITES)

  • 최정인;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제35권4호
    • /
    • pp.692-699
    • /
    • 2008
  • 본 연구의 목적은 표면처리가 기존의 레진과 새로운 레진 사이의 전단결합강도에 미치는 영향을 평가하는 것이다. 준비된 레진 시편을 6군으로 임의로 배분하여 각각의 표면처리를 한 후 수리용 레진을 축조하였다. 일주일간 보관 후 전단결합강도 를 측정하였고 일원분산 분석법으로 통계처리하여 다음과 같은 결과를 얻었다. 1. 3군과 4군(air abrasion)은 1군(산부식)에 비해 전단결합강도가 유의하게 높게 나타났다(p<0.05). 5군과 6군(diamond bur)은 1군(산부식)에 비해 높은 전단결합강도를 나타냈으나 통계적으로 유의하지 않았다(p>0.05). 2. 2군(자가부식 접착제)은 1군(산부식)에 비해 전단결합강도가 낮게 나타났으나 유의한 차이는 없었다(p>0.05). 3. 3군(air abrasion)과 4군(air abrasion+산부식)에서 전단결합강도의 차이는 유의하지 않았다(p>0.05). 4. 5군(diamond bur)과 6군(diamond bur+산부식)에서 전단결합강도의 차이는 유의하지 않았다(p>0.05). 결론적으로, 복합레진의 수리 시 air abrasion으로 표면처리를 했을 때의 결합강도가 가장 높았고, 산부식 방법과 처리여 부는 수리강도에 유의한 영향을 미치지 않았다.

  • PDF

자가부식 접착제의 레진 Tag 형성 (RESIN TAG FORMATION OF SELF-ETCHING ADHESIVES)

  • 김영재;장기택
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.143-152
    • /
    • 2003
  • 본 연구는 자가부식 접착제의 치질로의 침투와 레진 tag 형성을 알아보고 부가적인 산부식이 레진 tag 형성에 미치는 효과를 관찰하기 위하여 계획되었다. 3종의 자가부식 접착제(SE bond, AQ bond and L Pop)와 one bottle adhesive(Single bond)를 사용하였고 발거한 구치로 교합면 법랑질과 상아질 시편을 제작하였으며 각 군당 5개씩 네 개의 군으로 나눈 총 20개의 시편을 양분하여 각각 접착제를 적용하기 전 35% 인산으로 산부식하거나 산부식처리하지 않았으며 이후 레진을 적용시키고 중합하였다. 시편은 Silverstone microtome으로 절단한 후 HCl 용액과 NaOCl 용액으로 처리하고 건조시킨 후 이온으로 피복하였으며 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 부가적 산부식 처리한 상아질은 모든 자가부식 접착제군에서 산부식하지 않은 상아질보다 resin tag의 길이와 두께가 증가하는 것이 관찰되었다. 2. 법랑질에서는 L Pop을 제외하고 부가적 산부식한 군에서 레진 tag의 두께가 산부식하지 않은 군보다 컸고 보다 명확한 부식양상을 관찰할 수 있었다. L Pop에서는 부식법랑질과 비부식법랑질간의 차이가 없었다. 본 연구의 결과는 자가부식형 접착제가 법랑질을 부식시키지 않고 상아세관으로 침투하는 정도가 산부식군에 미치지 못하다는 것을 의미한다. 이와 관련하여 접착강도와 미세누출 및 레진 tag 형태에 대한 부가적 연구가 필요할 것이다.

  • PDF

지르코니아 코어의 표면처리방법이 열 가압 세라믹과의 전단결합강도에 미치는 영향 (The Influence of Surface Treatments on Shear Bond Strength between Zirconia Core and Heat Press Ceramic Interface)

  • 박항민;정인성
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.23-30
    • /
    • 2009
  • All-ceramic restorations have gained acceptance among clinicians and patients because of their superior esthetics. Most all-ceramic systems have a 2-layer structure, using a weak veneering ceramic over a strong supporting core. often, failure of all-ceramic restorations occurs when the veneering ceramic fractures, exposing the core material. The purpose of this study was to compare the shear bond strength of heat press ceramic system (Zirpress) to zirconia core with various surface treatments. 10 metal cores and 50 zirconia cores were fabricated and divided into six groups according to surface treatment such as Zirliner application, aluminium oxide blasting, and 9.5% HF etching. Sixty specimens were prepared using Zirpress, veneered 8mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 12.93 for $110{\mu}m$ aluminium oxide blasting/Rexillium III/IPS e.Max Zirpress; 14.92 for $50{\mu}m$ aluminium oxide blasting ${\pm}9.5%$ HF etching/Zirconis core/IPS e.Max Zirpress; 16.37 for $110{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 12.89 for $200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.30 for 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.55 for Zirliner/Zirconis core/IPS e.Max Zirpress. The mean shear bond strength for ZNTZH (Zirliner/Zirconis core) and ZNTEH (9.5% HF etching/Zirconis core) were significantly superior to MS110H ($110{\mu}$ aluminium oxide blasting/Rexillium III) and ZS200EH ($200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core) (p<0.05).

  • PDF

The effect of casein phosphopeptide amorphous calcium phosphate on the in vitro shear bond strength of orthodontic brackets

  • Park, Sun-Youn;Cha, Jung-Yul;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제43권1호
    • /
    • pp.23-28
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) on the shear bond strength (SBS) of brackets bonded to non-demineralized teeth with either phosphoric acid etching or self-etching primer. Methods: Sixty human premolars were randomly assigned to 1 of 4 treatment groups (n = 15 each): phosphoric acid etching (group 1); self-etching primer (group 2); CPP-ACP for 2 weeks + phosphoric acid etching (group 3), and CPP-ACP for 2 weeks + self-etching primer (group 4). After bonding of the maxillary premolar metal brackets, specimens were subjected to shear forces in a testing machine. Scanning electron microscopy was used to observe etching patterns on the enamel surfaces of all teeth. A 2-way analysis of variance was used to test for effects of CPP-ACP and etching system on SBS. Results: Significantly higher mean SBSs were observed in groups subjected to phosphoric acid etching (i.e., groups 1 and 3; p < 0.05). On the other hand, SBSs did not appear to be influenced by CPP-ACP (i.e., groups 3 and 4; p > 0.05). We observed a uniform and clear etched pattern on the enamel surface of the phosphoric acid etching groups. Conclusions: CPP-ACP does not significantly affect the SBS of orthodontic brackets bonded to non-demineralized teeth, regardless of which adhesive method is used to bond the brackets.

접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향 (The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system)

  • 류원일;손원준;백승호;이인한;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.385-396
    • /
    • 2011
  • 연구목적: 본 연구는 치근벽의 전처리 개념과 접착제의 중합방법이 레진계 근관충전제의 치근단 밀폐능에 미치는 영향을 평가하였다. 연구 재료 및 방법: 3가지 다른 접착변수를 조합하여 충전한 Resilon-RealSeal 시스템의 근단미세누출을 색소침투법을 이용하여 통상의 가타퍼쳐 충전과 비교하였다. 실험군은 자가부식형 RealSeal primer와 이중중합형 RealSeal sealer를 이용하여 Resilon 충전한 SEDC군, 산부식없이 Scotchbond Multi-Purpose primer를 적용한 후 접착제는 광중합하고 Resilon을 충전한 NELC군, 및 Scotchbond Multi-Purpose의 접착강화제와 접착제를 total etch/wet bonding과 광중합의 술식을 정확하게 지켜서 Resilon을 충전한 TELC군으로 구분하였다. 대조군(GPCS)에서는 통상의 AH26 plus sealer를 사용하여 가타퍼쳐를 충전 하였다. 결과: 치아장축방향의 색소침투는 TELC군에서 GPCS군과 SEDC군에 비해 유의하게 작았다(Kruskal-Wallis test, p < 0.05). 횡단면의 미세누출 점수도 TELC군이 근첨으로부터 2 - 5 mm의 범위에서 다른 군에 비해 유의하게 낮았다(Kruskal-Wallis test, p < 0.05). 결론: 레진계 근관충전제를 사용 시에는, 자가부식형 전처리제와 이중중합형 sealer보다는, total etch/wet bonding 개념과 적절한 광중합을 도모하는 전처리제 및 접착제의 사용이 치근단 미세누출을 감소시키므로 추천된다.

산부식 시간과 도포 횟수에 따른 불화 카제인포스포펩타이드-아모르포우스칼슘포스페이트의 치아 법랑질 재광화 효과 (Remineralization effect of casein phosphopeptide-amorphous calcium fluoride phosphate on the tooth enamel according to the etching time and frequency of application)

  • 정수진;이미라
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5602-5609
    • /
    • 2014
  • 본 연구는 카제인포스포펩타이드-아모르포우스칼슘포스포페이트(CPP-ACP)에 불소이온을 결합시킨 불화 카제인포스포펩타이드-아모르포우스칼슘포스페이트(CPP-ACFP)제제의 법랑질 재광화 정도를 알아보기 위한 실험으로 법랑질 표면에 산부식 시간을 달리한 후 CPP-ACFP제제를 같은 횟수로 도포했을 때의 재광화 정도와 CPP-ACFP제제의 도포 횟수가 법랑질의 재광화에 미치는 영향을 알아보고자 건전한 치아 64개를 대상으로 미세경도측정, 주사전자현미경 관찰 실험을 하였다. 그 결과 산부식 시간이 길어질수록, CPP-ACFP제제의 도포 횟수를 증가시킬수록 법랑질의 재광화가 더 잘 일어나는 것을 관찰할 수 있었다. 그러므로 CPP-ACP에 불소이온을 결합시켜 치아에 무기질 공급과 불소도포를 한 번에 할 수 있는 CPP-ACFP제제는 법랑질 재광화 물질로 권장할 만하다고 하겠다.