• Title/Summary/Keyword: Dental esthetic

Search Result 690, Processing Time 0.024 seconds

Full mouth rehabilitation on the patient with class II jaw relation and posterior bite collapse using reestablishment of occlusal vertical dimension: a case report (구치부 교합지지가 상실된 II급 악간관계 환자의 교합 재설정을 통한 완전 구강회복 증례)

  • Kim, Jae-Hyun;Cho, Hye-Won;Jung, Ji-Hye
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.262-272
    • /
    • 2015
  • Loss of molar support and abnormal jaw relationship lead to occlusal disharmony and cause pathologic signs. Full mouth rehabilitations with reestablishment of occlusal schemes are needed. In this case, the 75 year-old female patient showed posterior bite collapse, irregular occlusal plane and Class II jaw relationship. By observing her profile and interocclusal distance, she was diagnosed as loss of occlusal vertical dimension. Treatment plan is to restore maxillay class I removable partial denture and mandibular fixed prosthesis and to establish vertical dimension and harmonious occlusal plane. Occlusal vertical dimension of 19 mm, which is obtained by 7.5 mm increase between maxillary right lateral incisor and mandibular canine, was established using temporary prosthesis via diagnostic wax-up. Patient adaptation with newly formed vertical dimension was verified during 8 week follow-up period. Within the information of interim prostheses, final restoration was constructed and delivered. The patient showed sound occlusal scheme and esthetic profile.

Full mouth rehabilitation utilizing implant-assisted removable partial denture with a canted occlusal plane: a case report (경사진 교합평면을 갖는 환자에서 임플란트 보조 국소의치를 이용한 전악 수복 증례)

  • Han, A-Reum;Kwon, Tae-Min;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2016
  • Implant-assisted removable partial denture (Implant-assisted RPD, IARPD), posterior edentulous extension areas of which obtains additional support and retention from implants, is attracting increasing interest. This case report presents a successful treatment on a partially edentulous patient with a severely canted occlusal plane resulted from a long-term use of posterior extended RPD. The full mouth was rehabilitated through a fixed prosthesis on maxilla and IARPD with zirconia occlusal surface on mandible, which allowed to achieve an esthetic occlusal plane with long-term stability and, ultimately, functionally satisfying outcome.

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.

A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient (상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례)

  • Seong, Si Young;Choi, Yeon Jo;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • When planning oral rehabilitation for maxillary edentulous patients, fixed prosthetic restoration using implants, complete denture restoration or overdentures using implants can be considered as treatment methods. In the case of complete denture restoration, it does not require additional surgery and is relatively economical. In the case of implant-supported fixed prostheses, the functional part is generally superior to that of complete denture restoration, but there are cases in which implant placement is clinically difficult. Recently in consideration of the patient's needs and the condition of the remaining alveolar bone, after partial implant placement, a method of restoring with a removable partial denture using implant-supported surveyed crown is also being attempted. This case is a case of performing a removable partial denture restoration using implant-supported surveyed crown in the anterior maxilla, and showing satisfactory esthetic and functional results.

Oral rehabilitation of edentulous patient with mandibular implant overdenture using surgical guide (서지컬 가이드를 이용한 하악 임플란트 피개의치 수복 증례)

  • Lee, Dong Hwan;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • Compared with traditional full dentures, mandibular implant overdentures have the advantage in that good support and retention can be obtained even with two implants. When manufacturing a mandibular implant overdenture using two implants, it is important to place the implant in the correct position. The long-term prognosis of overdenture is good when two implants are placed in the direction vertical to the occlusal plane and parallel to each other at the canine position. However, it is difficult to place two implants in the correct position in edentulous patients, and if you use surgical guides in these cases, you can get help in placing the implants in a prosthetically advantageous position. This case, a 57-year-old male patient, came to our hospital with all upper and lower teeth removed due to periodontal disease. Therefore, the maxilla was restored with a traditional full denture and the mandible was restored with an implant overdenture using two implants, which resulted in satisfactory functional and esthetic results.

Deep proximal margin rebuilding with direct esthetic restorations: a systematic review of marginal adaptation and bond strength

  • Hoda S. Ismail;Ashraf I. Ali;Rabab El. Mehesen;Jelena Juloski;Franklin Garcia-Godoy;Salah H. Mahmoud
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.15.1-15.18
    • /
    • 2022
  • This review aimed to characterize the effect of direct restorative material types and adhesive protocols on marginal adaptation and the bond strength of the interface between the material and the proximal dentin/cementum. An electronic search of 3 databases (the National Library of Medicine [MEDLINE/PubMed], Scopus, and ScienceDirect) was conducted. Studies were included if they evaluated marginal adaptation or bond strength tests for proximal restorations under the cementoenamel junction. Only 16 studies met the inclusion criteria and were included in this review. These studies presented a high degree of heterogeneity in terms of the materials used and the methodologies and evaluation criteria of each test; therefore, only a descriptive analysis could be conducted. The included studies were individually evaluated for the risk of bias following predetermined criteria. To summarize the results of the included studies, the type of restorative material affected the test results, whereas the use of different adhesive protocols had an insignificant effect on the results. It could be concluded that various categories of resin-based composites could be a suitable choice for clinicians to elevate proximal dentin/cementum margins, rather than the open sandwich technique with resin-modified glass ionomers. Despite challenges in bonding to proximal dentin/cementum margins, different adhesive protocols provided comparable outcomes.

New anterior guidance induction through spontaneous gap closure after an increase in vertical dimension: a case report (교합고경 증가로 발생한 전치부 공간을 자연 폐쇄시켜 새롭게 유도한 전방유도: 증례 보고)

  • Jung Hyun Nam;Jong-Hee Kim;Yang-Jin Yi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.146-157
    • /
    • 2023
  • The bite collapses due to posterior teeth loss or wear results in inadequate space for restoration and esthetic concerns. Increasing the occlusal vertical dimension to improve space deficiency rotates the mandible posteriorly, creating a gap between the maxillary and mandibular anterior teeth, leading to loss of anterior guidance. To solve this problem, the prosthodontics or orthodontics treatments are the commonly used methods for proper anterior guidance. However, it is reasonable to assume that the anterior teeth can naturally relapse to their original position when the occlusal force is eliminated. Therefore, this case report aimed to test whether natural relapse could recover the lost anterior guidance to develop a less invasive and more convenient treatment method. Digital superimposition was used to evaluate the changes in anterior teeth alignment to confirm the change of the recovered anterior guidance. The appropriate indications for this new treatment method were defined and applied clinically.

Fixed implant rehabilitation of maxillary edentulous patient using intraoral scanning digital workflow: a case report (상악 완전 무치악 환자에서 구강 스캐닝 디지털 워크플로우를 활용한 완전 고정성 임플란트 수복 증례)

  • Seung Min Park;YoungBum Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.38-46
    • /
    • 2024
  • In order to treat edentulous patients with fixed implant prosthesis, the final prosthesis form should be predetermined based on the anatomic structures of the arch, the opposing dentition, and the occlusal plane. The design and occlusion of the interim prosthesis can provide useful information when fabricating the definitive prosthesis. In this case report, scan data of the edentulous region and the interim prosthesis were superimposed through an intraoral scanning digital workflow. In this way, the interim prosthesis information was incorporated into the design of the final prosthesis. Furthermore, the interim prosthesis data acquired through intraoral scanning was utilized to plan the positions and angles of the implants based on the final prosthesis design. Surgical guides were used to accurately place the implants in the planned three-dimensional positions. In this case report, satisfactory esthetic and functional clinical outcomes were achieved through application of digital techniques.

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.