• 제목/요약/키워드: Dental error

검색결과 191건 처리시간 0.026초

CONFUTER-AIDED CASTING DESIGN FOR IMPLANT TITANIUM SUPERSTRUCTURES (컴퓨터 시뮬레이션을 이용한 임플란트 상부 티타늄 구조물의 주조방안)

  • Oh Se-Wook;Lee Ho-Yong;Lee Keun-Woo;Shim Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제41권4호
    • /
    • pp.421-439
    • /
    • 2003
  • Statement of problem : It is difficult to obtain a good titanium casting body using the traditional sprue design because of high melting point of Ti, and the low fluidity and high reactivity of molten Ti. Purpose : A new sprue design for titanium casting bodies needs more trial and error. In order to decrease the number of trial and error, computer simulation(MAGMASOFT, Magmasoft Giessereitechnologie GmbH, Achen, Germany) was used to optimize sprue design in U-shaped implant superstructures. Material and method : Five kinds of sprue were examined for the design of the sprue former for titanium casting: Sprue design A(sprue length 4 mm, rectangular shape, 4 sprues), Sprue design B(sprue length 4 mm. round shape. radius 2 mm, 7 sprues), Sprue design C (sprue length 2 mm, round shape, radius 2 mm, 7 sprues). Sprue design D (sprue length 2 mm, cone shape, large radius 3mm. small radius 2mm, 7 sprues), and Sprue design E( sprue length 2 mm. one unit channel shape). Sprue design F(sprue length 2mm, one unit channel shape) was also examined for the design of the customized sprue former in the Biotan system(Schutz Dental Gmbh, Germany). The casting bodies were taken in Sprue design A, Sprue design D, Sprue design E, and Sprue design F in the Biotan casting system. The numerically predicted defects were compared with the experimental dental castings by the radiographic and sectional view observations. Results : 1. According to the result of computer simulation, turbulence during mold filling was decreased in the sequence of Sprue design F, Sprue design E, Sprue design D, Sprue design C, Sprue design B, and Sprue design A. 2. The calculated solidification time contours indicate that hot spot was moved from the casting body to the sprue button in the sequence of Sprue design A, Sprue design B, Sprue design C, Sprue design D, and Sprue design E. The filling pattern of Sprue design F was similar to that of Sprue design E. 3 The predicted filling pattern shows that less turbulence was found in the customized sprue former than in the standard sprue former. 4. According to the results of the radiographic and cross sectional observations, casting defects less than 1mm were found at the center of a casting body with Sprue design E and Sprue design F. However, larger casting defects of 4mm were found in a casting with Sprue design A. 5. The predicted casting porosity was similar to that of the real casting. Conclusion : One unit channel-type and customized sprue former can be recommended. Further research and developement of various sprue designs using computer simulation in necessary to optimize casting design, in order to reduce the formation of casting defects in implant titanuim super-structures.

Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

  • Park, Jin-Yi;Kim, Dasomi;Han, Sang-Sun;Yu, Hyung-Seog;Cha, Jung-Yul
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.257-263
    • /
    • 2019
  • Purpose: This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models. Materials and Methods: A pair of PVS impressions was obtained from 20 subjects and scanned using CBCT (resolution, 0.1 mm). A cast scan model was constructed by scanning the gypsum model using a model scanner. After reconstruction of the digital models, the mesio-distal width of each tooth, inter-canine width, and inter-molar width were measured, and the Bolton ratios were calculated and compared. The 2 models were superimposed and the difference between the models was measured using 3-dimensional analysis. Results: The range of mean error between the cast scan model and the CBCT scan model was -0.15 mm to 0.13 mm in the mesio-distal width of the teeth and 0.03 mm to 0.42 mm in the width analysis. The differences in the Bolton ratios between the cast scan models and CBCT scan models were 0.87 (anterior ratio) and 0.72 (overall ratio), with no significant difference (P>0.05). The mean maxillary and mandibular difference when the cast scan model and the CBCT scan model were superimposed was 53 ㎛. Conclusion: There was no statistically significant difference in most of the measurements. The maximum tooth size difference was 0.15mm, and the average difference in model overlap was 53 ㎛. Digital models produced by scanning impressions at a high resolution using CBCT can be used in clinical practice.

A LATERAL CEPHALOMETRIC STUDY OF THE PHARYNGEAL GROWTH IN KOREAN CHILDREN (아동기 인두강의 크기에 관한 방사선학적 연구)

  • Choi Ki Chae;Lee Sang Rae;Lee Man Sup
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제20권1호
    • /
    • pp.63-70
    • /
    • 1990
  • The aim of this study has been to investigate the growth of the pharynx and sexual differences in the lateral cephalograms of Korean children. The material includes 173 cepalograms from two groups composed of 51 males aged 12.0 years and 39 females aged 12.2 years in group 2, and 45 males aged 7.4 years and 39 females aged 7.5 year in group 1, respectively. In order to study and measure the pharyngeal area the following skeletal landmarks were selected: S, N, A, Ptm, B, H, H', M, S-N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper head positioning of subjects, especially in relative positions of A and H, while radiography. For each variable the statistically treated data have been presented in the table Ⅱ, Ⅲ, Ⅳ. The main results are presented as follows: 1. In general, the measurements of male were larger than those of female in antero-posterior dimension of pharyngeal cavity, but all variables did not show significant sexual differences in both groups when evaluated statistically. 2. All of the measurements were larger in male than in female in vertical dimensions of pharyngeal cavity in group 2, and there were statistical significances of sexual differences in the variables except M-H', but all variables did not show significant sexual differences in group 1 when evaluated statistically. 3. The dimensional increase of the pharynx by the growth in the vertical dimensions was shown to be greater than in the antero-posterior dimensions in the both sexes.

  • PDF

Age Estimation with Panoramic Radiomorphometric Parameters Using Generalized Linear Models

  • Lee, Yeon-Hee;An, Jung-Sub
    • Journal of Oral Medicine and Pain
    • /
    • 제46권2호
    • /
    • pp.21-32
    • /
    • 2021
  • Purpose: The purpose of the present study was to investigate the correlation between age and 34 radiomorphometric parameters on panoramic radiographs, and to provide generalized linear models (GLMs) as a non-invasive, inexpensive, and accurate method to the forensic judgement of living individual's age. Methods: The study included 417 digital panoramic radiographs of Korean individuals (178 males and 239 females, mean age: 32.57±17.81 years). Considering the skeletal differences between the sexes, GLMs were obtained separately according to sex, as well as across the total sample. For statistical analysis and to predict the accuracy of the new GLMs, root mean squared error (RMSE) and adjusted R-squared (R2) were calculated. Results: The adjusted R2-values of the developed GLMs in the total sample, and male and female groups were 0.623, 0.637, and 0.660, respectively (p<0.001), while the allowable RMSE values were 8.80, 8.42, and 8.53 years, respectively. In the GLM of the total sample, the most influential predictor of greater age was decreased pulp area in the #36 first molar (beta=-26.52; p<0.01), followed by the presence of periodontitis (beta=10.24; p<0.01). In males, the most influential factor was the presence of periodontitis (beta=9.20; p<0.05), followed by the number of full veneer crowns (beta=2.19; p<0.001). In females, the most influential predictor was the presence of periodontitis (beta=18.10; p<0.001), followed by the tooth area of the #16 first molar (beta=-11.57; p<0.001). Conclusions: We established acceptable GLM for each sex and found out the predictors necessary to age estimation which can be easily found in panoramic radiographs. Our study provides reference that parameters such as the area of tooth and pulp, the number of teeth treated, and the presence of periodontitis should be considered in estimating age.

A retrospective institutional study of human age determination by evaluating the pulp length and width ratio of the maxillary lateral incisor on panoramic radiographs in Indonesian subjects

  • Herianti, Vanessa Rizka;Oscandar, Fahmi;Dardjan, Murnisari
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.421-427
    • /
    • 2021
  • Purpose: The pulp length to width (PL/W) ratio of the maxillary lateral incisor can be used as an age determination method. This study aimed to investigate the correlation between the PL/W ratio of the maxillary lateral incisor on panoramic radiographs and human chronological age in Indonesian subjects. Materials and Methods: This study analyzed with 134 maxillary lateral incisors on 113 panoramic radiographs from patients who visited the Oral and Maxillofacial Radiology Unit of Dental Hospital Universitas Padjadjaran, Bandung, Jawa Barat, Indonesia, from 2013 to 2018 (age range: between 11 to 60 years). The pulp length was measured from the pulp chamber roof to the apical foramen, and the pulp width was measured on the cervical area of the cementoenamel junction in millimeters using Fiji ImageJ open-source software. Simple linear regression (in SPSS) was used to analyze the results. The reliability of the observers was evaluated. Results: The PL/W ratio of the maxillary lateral incisor was significantly correlated with chronological age (P<0.01). No statistically significant difference was found in the PL/W ratio between the left and right maxillary lateral incisors(P=0.333). There was a very strong correlation (r=0.939) between the PL/W ratio of the maxillary lateral incisor and human chronological age, with the following formula: age= -3.057+1.875×PL/W ratio (R2=0.882, standard error of estimate: 4.659). Conclusion: The PL/W ratio of the maxillary lateral incisor on panoramic radiograph can be used for age determination in Indonesian subjects.

A Study for the development of the Korean orthodontic bracket (한국형 교정치료용 Bracket의 개발에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Moon, Seong-cheol
    • The korean journal of orthodontics
    • /
    • 제30권5호
    • /
    • pp.565-578
    • /
    • 2000
  • The aim of this study was development of the Straight-Wire Appliance(SWA) suitable lot the treatment or Korean. To accomplish the object of this study, Korean adult with normal occlusion were selected with following criteria : 1) no functional abnormality in the craniofacial area, 2) good dental arch form and posterior occlusal relationship, 3) Angle Class I occlusal relationship, 4) no experience of orthodontic, nor prosthodontic treatment, especially, no dental treatment on labial and buccal surfaces of teeth, 5) good racial profile. Impression were taken for upper and lower dental arches or the selected normal occlusion samples and the orthodontic dental stone models were fabricated. 5 well-trained orthodontists had examined the acquired dental stone models to select study samples which satisfy the Six keys to optimal occlusion of Andrews. 155 pairs of dental stone models (92 pairs of Male, 63 of Female) were finally selected. 3 dimensional digitization were performed with the Coordinate Measuring Machine(CMM, MPC802, WEGU-Messtechnik, Germany) and measuring of Angulation, Inclination, In-and-Out, Molar offset angle and Arch form were accomplished with a measuring software to achieve data for the development of SWA. Before the measurement, error study was performed on the 3 dimensional digitization with CMM, and the analysis of reliability of computerized measuring method adapted in this study and conventional manual method Presented by Andrews was performed. Results of this study were as to)lows : 1. Equi-distance digitization with mesh size 0.25 mm, 0.5 mm and 1.0 mm were acceptable in 3 dimensional digitization of dental stone model with the CMM, and the digitization with 1.0 mm mesh size was recommendable in terms of efficiency. 2. Computerized measuring method with 3 dimensional digitization was more reliable than manual measuring method of Andrews. 3. Data were collected for the development of SWA suitable for the morphological characteristics of Korean with the computerized measuring method with 3 dimensional digitization.

  • PDF

Respiratory air Flow Transducer Based on air Turbulence (와류 현상을 이용하는 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Yoon-Kee;Kim, Kyung-Chun;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • 제30권5호
    • /
    • pp.393-400
    • /
    • 2009
  • The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the devices for cardiopulmonary resuscitation(CPR) procedure. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object existed on the flow stream, but still the flow rate could be evaluated. Computer simulation demonstrated stable turbulence formation big enough to measure. Experiment was followed on the proto-type transducer, the results of which were within ${\pm}5%$ error compared to the simulation data. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999(P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

ANALYSIS OF SPEECH PATHOLOGIC EVALUATION FOR CHILDREN WITH ANKYLOGLOSSIA (설유착증 환아의 언어병리학적 평가)

  • Lee, Ju-Kyung;Kim, Young-Bin;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Ok, Seung-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.447-456
    • /
    • 2008
  • There is close relationship between intraoral structural anomaly and speech- functional problem. Patient with cleft palate patients & ankyloglossia is a typical example, patients with structural anomaly is repaired toward normal structure by operation. Ankyloglossia may cause functional limitation even after adequate surgical treatment speech disorders being one of them. Interindividually, they vary a lot, showing typical articulation specifics. The objective of this study was to evaluate and compare speech for children with ankyloglossia and general public, to determine whether ankyloglossia is associated with articulation problem. We wanted to present criteria for indication of frenectomy. The group of subject is composed of 10 childrens with ankyloglossia and articulation problem, visited the Oral and Maxillofacial surgical unit, dental hospital, Chonbuk university. The average age is 5 Y 7M, M : F ratio is 8 : 2 at the time of speech test. Control group is composed of 10 members without oral structural anomaly. The average age is 5 Y 10M, M : F ratio is 3 : 7 at the time of speech test. Outcomes were measured the PPVT(Peabody Picture Vocabulary Test), PCAT(Picture Consonant Articulation Test), Nasometer II test result obtained each group, statistically measured by Mann-whitney's U Test. There was no difference for 'chronological age-age equivalent' between two group. There was significant difference for 'consonant accuracy' between two group, showed more lower scores in subject group. There was more 'consonant error' in subject group, mostly showed/1/,/s/. A major modality of 'consonant error' was mostly distortion and replacement. There was no significant difference between two group for nasality.

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제21권11호
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

A Study on the Accuracy of Scan by the Standard Model Deformation Depending on the Hand Scanning Method (핸드스캐닝 작업 방법에 따라 표준 모델 변형이 작업 정밀도에 미치는 정밀스캔에 관한 연구)

  • Shin, Seong-Hun;Jang, Seong-Ho;Song, Joon-Ki;Park, Kwang-Sig;Lee, Hee-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권4호
    • /
    • pp.197-202
    • /
    • 2018
  • This study was conducted to evaluate the distortion and data accuracy that may occur depending on the methods employed by the oral scanner (intra-oral scanner). Deseutap 3D models employing a plaster model used clinically as a scanner to create a standard scan data using the same model, separated by oral scanners in three different ways (AS Group, ZS group, OS group) How to scan each 5 times made the scan data for each group, it shows the 0.121 mm, 0.172 mm AS group, OS group 0.423 mm accuracy in ZS group. The ZS group showed the highest accuracy, with maximum error values of 0.113 mm, 0.169 mm and 0.246 being observed for the ZS, AS and OS group, respectively. The three scanning methods showed a clear differences in accuracy and reproducibility and also appeared to be meaningful in clinical practice.