• Title/Summary/Keyword: Dental crowns

Search Result 343, Processing Time 0.025 seconds

Stress analysis according to the vertical bone level in the implant placement (임플란트 매식 시 수직골 높이에 따른 응력분석)

  • Kim, Min-Ho;Park, Young-Rok;Kay, Kee-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.

TREATMENT OF FUSED PERMANENT MANDIBULAR LATERAL AND CENTRAL INCISORS: REPORTS OF CASES (유합된 하악 영구 중절치와 측절치의 치료에 관한 증례보고)

  • Han, Jeong-Jae;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.795-804
    • /
    • 1997
  • Developmental dental morphological anomalies are fusion, gemination, twinning, concrescence and etc. They may cause many problems in conservative, periodontal and esthetic aspects. Fusion is a condition where two separate tooth buds unite at some stage in their development to form a bifid crown. If tooth contact occurs early, at least before the start of calcification, the two teeth may be completely unites to form a single large tooth. If tooth contact occurs after the time when a portion of the tooth crown has completed its formation, there may be union of the roots only. In fusion the dentin is always confluent. Fusion teeth is more common in the deciduous than in the permanent dentition. Fused teeth are relatively rare, and are mostly mandibular anterior teeth. Fusion of normal and supernumerary teeth or between normal teeth may occurs. The exact etiology factor of fusion is unknown, but genetic and environmental factors seems to be related. A variety of complications and subsequent treatments have been suggested on this teeth. Periodontal conditions may arise due to a groove formed at the line of fusion of the two teeth. Crowding or Protrusion with potential for malocclusion or delayed eruption of adjacent teeth. Fusion teeth appear in the anterior region, they usually cause esthetic problems. Treatments vary depending on the problem, the location, and the extent of fusion. Treatment of fused teeth has been reported from endodontic, orthodontic, periodontic, surgical and multidisciplinary. This report presents the esthetic improvements by separation of two clinical crowns. Bone reduction or endodontic treatments are not required.

  • PDF

THE INFLUENCE OE BALANCING SIDE OCCLUSAL INTERFERENCE ON THE MASTICATORY MUSCLE ACTIVITY AND CONDYLAR PATH (균형측 교합장애가 저작근 활성도 및 과로에 미치는 영향에 관한 연구)

  • Jin, Tai-Ho;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.103-121
    • /
    • 1989
  • The purpose of this study was to investigate the influence of balancing interference on the activity of masticatory muscles and condylar path. Eight dental students of Won Kwang University without any symptoms of temporomandibular disorder and occlusal interferences, were selected for this study, The balancing interference was provided by construction and cementation of cast metal crowns on the upper and lower first molars. For the measurement of muscle activity, bioelectric processor (EM2, Myotronic Res., Inc., U.S.A.) was used and for the condular path, computerized electronic pantograph (Pantronics, Denar Corp., U.S.A.) was used and the myographic recordings were taken bilaterally from the anterior temporal, masseter and digastric muscles on rest position and on functions. These experimental procedures were done before cementation of experimental crown, three days after cementation of experimental crown, one week after, two weeks after and then one week after removal of experimental crown. The results are as follows: 1. The PRI score was increased at three days after application of balancing interference, and decreased at two weeks after. 2. Three subjects showed mild symptom of temporomandibular disorder at three or four days after application of interference, but the symptom was subsided in one or two weeks after application of interference. 3. One week after application of balancing interference, the activity of ipsilateral anterior temporal muscle in four subjects was decreased on gum chewing at experimental site. 4. Three days after application of balancing interference, the activity of ipsilateral anterior temporal muscle in three subjects was increased on gum chewing at non-experimental site. 5. The influence of balancing interference on the activity of anterior temporal, masseter and gigastric muscle was not prominent.

  • PDF

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

Esthetic restoration of malpositioned anterior teeth by tooth shape and gingival contour modification : a clinical report (위치이상 치아의 치은 성형을 동반한 심미적 보철수복)

  • Kim, Ja-Yeong;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.143-149
    • /
    • 2015
  • In esthetic treatments, it is important to consider the arrangement of teeth and the relation between the teeth and soft tissues. A precise diagnosis and establishing an appropriate treatment plan is essential in an esthetic treatment of anterior maxillary teeth. For a fixed prosthesis to meet esthetic expectations, It is crucial to achieve symmetry and adequate proportions of the gingival contour around the crowns. To achieve an esthetic improvement and creating a favorable environment for gingival healing of a physiologic gingival contour, gingivectomy, crown lengthening and forced eruption can be applied to the appropriate site. All ceramics or porcelain laminate veneer can be selected for esthetic improvement of teeth contour and shade. In this case report, malposition of the remaining teeth made it hard to get an esthetic appearance. Gingivectomy, crown lengthening and provisional restoration insertion were performed before the final prosthesis fabrication to reform the gingival form. This case presents satisfying result esthetically and functionally.

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report (CAD/CAM을 이용하여 기존 국소의치에 맞는 지대치 보철물 제작 증례)

  • Chae, Min-Jeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.490-494
    • /
    • 2019
  • Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.

Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

  • Abdullah, Adil Othman;Hui, Yu;Sun, Xudong;Pollington, Sarah;Muhammed, Fenik Kaml;Liu, Yi
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.65-74
    • /
    • 2019
  • PURPOSE. To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS. 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS. Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions ($1.05{\pm}0.24{\mu}m$, $1.30{\pm}0.21{\mu}m$) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions ($30.97{\pm}3.12MPa$, $29.09{\pm}4.17MPa$), while group SLV recorded the lowest ($23.96{\pm}3.60MPa$, $22.95{\pm}3.68Mpa$) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION. GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.

Histological analysis on tissues around orthodontically intruded maxillary molars using temporary anchorage devices: A case report

  • Hui-Chen Tsai;Julia Yu-Fong Chang;Chia-Chun Tu;Chung-Chen Jane Yao
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.125-136
    • /
    • 2023
  • Before progress was recently made in the application of temporary anchorage devices (TADs) in bio-mechanical design, orthodontists were rarely able to intrude molars to reduce upper posterior dental height (UPDH). However, TADs are now widely used to intrude molars to flatten the occlusal plane or induce counterclockwise rotation of the mandible. Previous studies involving clinical or animal histological evaluation on changes in periodontal conditions after molar intrusion have been reported, however, studies involving human histology are scarce. This case was a Class I malocclusion with a high mandibular plane angle. Upper molar intrusion with TADs was performed to reduce UPDH, which led to counterclockwise rotation of the mandible. After 5 months of upper molar intrusion, shortened clinical crowns were noticed, which caused difficulties in oral hygiene and hindered orthodontic tooth movement. The mid-treatment cone-beam computed tomography revealed redundant bone physically interfering with buccal attachment and osseous resective surgeries were followed. During the surgeries, bilateral mini screws were removed and bulging alveolar bone and gingiva were harvested for biopsy. Histological examination revealed bacterial colonies at the bottom of the sulcus. Infiltration of chronic inflammatory cells underneath the non-keratinized sulcular epithelium was noted, with abundant capillaries being filled with red blood cells. Proximal alveolar bone facing the bottom of the gingival sulcus exhibited active bone remodeling and woven bone formation with plump osteocytes in the lacunae. On the other hand, buccal alveolar bone exhibited lamination, indicating slow bone turnover in the lateral region.