• Title/Summary/Keyword: Dental attrition

Search Result 55, Processing Time 0.024 seconds

Intraoral ageing of aligners and attachments: Adverse effects on clinical efficiency and release of biologically-active compounds

  • Theodore Eliades;George Eliades
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.199-209
    • /
    • 2024
  • The clinical application of aligners is accompanied by the ageing of the polymer appliances and the attachments used, which may result in inefficiency in reaching the predicted range of tooth movement, and release of compounds and microplastics in the oral cavity as a result of the friction, wear and attrition of the aligner and composite attachment. The purpose of this review is to present the mechanism and effects of in vivo ageing; describe the hydrolytic degradation of aligners and enzymatic degradation of composite attachments; examine the ageing pattern of aligners in vivo, under actual clinical scenarios; and identify a link to the discrepancy between predicted and actual clinical outcome. Lastly, strategies to deal with three potentially critical issues associated with the use of aligners, namely the necessity of weekly renewal, the dissimilar mechanical properties of aligner and attachment resulting in wear and plastic deformation of the aligner, and the development of integuments and biofilms with microbial colonization of the appliance, are discussed.

DENTAL TREATMENT OF A PATIENT WITH BARTTER SYNDROME: CASE REPORT (Bartter 증후군 환아의 치아우식 치료: 증례보고)

  • Kim, Minji;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Jang, Ki-Taeg
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.45-49
    • /
    • 2019
  • Bartter syndrome is an inherited renal tubular disorder characterized by hypokalemia, hypochloremic metabolic alkalosis, hyperreninemia, hyperprostaglandinism, and normal blood pressure. Bartter syndrome is classified by neonatal and classic type. Clinical manifestation of Bartter syndrome considered in dental treatment include tendency to dehydration, vomiting and erosion, attrition and abrasion of the teeth. A 2-year-4 month old boy with Bartter syndrome type III was referred to the Seoul National University Dental Hospital for dental evaluation and treatment. He showed hypokalemic hypochloremic metabolic alkalosis and had been treated with indomethacin and potassium chloride. He had hypocalcified teeth with or without multisurface caries lesions in all dentition and the erosion of maxillary teeth was detected. Dental procedure under general anesthesia was scheduled due to multiple caries and his medical condition. The dental procedure was successfully performed. This case suggests that electrolyte imbalances need to be treated prior to dental treatment and complete coverage restoration is necessary to protect the eroded teeth. An appropriate management plan for the patients with Bartter syndrome should include considerations of the need for close interaction with the pediatrician for pre- and post-operative care. General anesthesia may be recommendable to manage the patients having multiple caries with Bartter syndrome.

The Relationship between Temporomandibular Disorders(TMD) and Occlusion (측두하악장애와 교합요인의 관계)

  • Kim, Seong-Taek;Lee, You-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.43-57
    • /
    • 2005
  • Temporomandibular disorders have been defined as a collective term embracing a number of clinical problems that involve the temporomandibular joint, the masticatory nuscles, and associated structures. There have been many different contributing factors of TMDs which were traumatic, occlusal, pathophysiological and psychosocial. Among there factors, the effect of occlusion on TMDs have been a controversy for a long time. The purpose of this study was to investigate the effect of occlusal factors and oral habits on TMDs. In this study, 140 subjects with signs and symptoms of TMDs and diagnosed of TMD in the Orofacial Pain clinic of Yonsei University Dental Hospital though March to July 2004 were selected for the TMDs group and 50 subjects without any signs and symptoms of TMDs as the control group. The subjects were evaluated clinically in TMDs' Occlusal and Prosthodontic Restoration examinations. TMDs' examination was composed of the TMJ pain, sound, locking, temporal or masseter muscle palpation, mandibular movement, oral habits and headache. Occlusal examination was made of overjet, overbite, lost teeth number, nonfunctional interference, midline shift, then pattern of lateral movement and attrition. prosthodontic restoration examination had the existence of restoration, placement, then number of crown or bridge and Satisfiable index which estimated the quality of occlusal state of prosthodontic restorations. Following results were obtained : 1. The prevalence of TMDs was higher in their 20s & 30s, female of the TMD patients group. 2. The clenching frequency in the TMDs group(40.71%) was higher than those in the control group(18.00%), and there was a significant statistical difference(p<0.05). 3. The frequency of Nonfunctional interference in the TMDs group(10.00%) was higher than those in then Control group(2.00%), and there was a significant statistical difference(p<0.05). The result of this study indicated TMDs prevalence was higher in their 20s, 30s, female group of TMDs patients similar to the previous studies. Clenching and nonfunctional interference were estimated as the contributing factors of TMDs.

Full-mouth rehabilitation with CAD/CAM monolithic zirconia in dentinogenesis imperfecta: a case report (상아질 형성 부전증 환자에서 CAD/CAM 단일 구조 지르코니아를 이용한 완전구강회복 증례)

  • Kim, Min-Kyoo;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Dentinogenesis Imperfecta, with a high incidence rate of 1 : 6 - 8000, is inherited by autosomal dominant genetic transmission. This dental disorder causes discoloration of the teeth and the enamel and dentin show hypoplastic or hypocalcified defects which lead to frequent fractures and rapid attrition. Therefore, timely treatment is necessary for the preservation of the remaining teeth. In this particular case, a 19-year-old patient suffering from Type 1 dentinogenesis imperfecta showed signs of brownish hued teeth with multiple fractures, a loss of vertical dimension, excessive interdental space in the maxillary anterior teeth, and a lack of 5 posterior teeth. To improve the esthetic appearance of the anterior teeth, the vertical dimension was increased. Resin caps were used to alleviate the difficulty of taking an impression of multiple teeth at once. Monolithic zirconia materials used in this case showed high fracture strength and the ability to mask the discoloration of the teeth and therefore, functionally and esthetically favorable results were achieved.

The influence of Advanced Adult Periodontitis on the pulp (진행성 치주염이 지수 조직에 미치는 영향)

  • Lee, Kang-Woon;Lee, Chel-Woo;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.95-102
    • /
    • 1999
  • The purpose of this study was to observe histopathologically the influence of advanced periodontitis on pulp tissue, and to conclude the correlation between the results with clinical manifestations. The samples were teeth with over 7mm pocket depth and over 50% radiographic bone loss. These were diagnosed to have very poor prognosis and thus planned to be extracted. Those with any of following conditions were excluded from the samples, loss of vitality, periapical pathology, restoration or prosthesis, dental caries, and attrition or abrasion. It was because these conditions could affect pulp without any correlation with periodontal disease. For the experiment, 17 teeth from 11 patients were selected. Average age of patient was 47. Each tooth was examined for following categoris; pocket depth, gingival recession, electric pulp test, mobility, percussion test, sensitivity test. The extracted teeth were fixed buffered neutral formalin solution. It was decalcified using 4% nitric acid. Sliced histological samples observed using light microscope, for pulp status, and severeity of inflammation. 4 samples were excluded due to histologic sample discrepency. Thus 13 samples were subject to observation. 4 showed normal conditions. Focal reversable pulpitis was shown in 5 samples. Chronic pulpitis was observed 1 sample. Pulpal abscess was observed in 3 samples.

  • PDF

Full mouth rehabilitation with extremely worn dentition (심한 치아 마모 환자의 전악보철 수복 증례)

  • Cha, Hwa-Ryun;Yeom, Kyeong-Yeon;Lee, Yong-Sang;Kim, Na-Hong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.238-244
    • /
    • 2017
  • Pathologic attrition leads to pathologic damage on occlusal plane, functional disorders, occlusal disharmony, esthetic problems, pulpal lesion, temporomandibular joint (TMJ) disorder. In this case, treatment plan should be considered for possibility of vertical dimension loss, occlusal pattern, esthetics, phonetics, amount of vertical dimension increase. This case report was a 71-year-old man who had severely worn dentition. Full mouth rehabilitation was carried out with vertical dimension increase due to limited space for prosthesis. After evaluation of provisional restorations for patient's compliance, final restorations were fabricated and routine clinical assessments were made. This case presents that a satisfactory clinical result was achieved by restoring the worn dentition.

Rehabilitation of the Worn Dentition (심하게 마모된 치열의 전악 수복에 대한 임상적 고찰)

  • Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.455-462
    • /
    • 2010
  • Patients often seek rehabilitative treatment for severely worn dentition. The etiology of noncarious tooth wear due to attrition, abrasion, and erosion is multifactorial. To treat the worn dentition, it is important to identify and eliminate and/or control the factors that contribute to excessive wear. Many situations requiring complete mouth rehabilitation present with the challenge of a lack of restorative space. To establish a correct occlusal plane and space for prostheses, it is necessary to increase vertical dimension. This may require an increase in occlusal vertical dimension. Also clinicians should be able to choose the appropriate restorative materials to achieve excellence in natural esthetics as well as proper biomechanics and durability. This article presents a method for altering occlusal vertical dimension to restore dentitions with limited restorative space due to loss of tooth structure.

Full mouth rehabilitation using zirconia crown in severe worn dentition: a case report (마모가 심한 환자에서 지르코니아 크라운을 이용하여 전악 수복한 증례)

  • Park, Jung-Hyun;Sohn, Sang-Hyuk;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • The progressive attrition of teeth is a normal process by aging. However, excessive tooth wear with decreased vertical dimension of occlusion and collapse of occlusal plane may cause pathologic pulpal condition, occlusal disharmony and functional disorders. In this case, a patient with severely worn dentition was treated. Diagnostic wax-up was performed at the increased vertical dimension. After evaluation of provisional restorations for 12 weeks, final restorations were fabricated with zirconia crown and routine clinical assessments were made. Esthetically and functionally satisfactory results were obtained.

Fractures of implant fixtures: a retrospective clinical study

  • Yu, Han-Chang;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.13.1-13.6
    • /
    • 2020
  • Background: The aim of this study was to evaluate the factors that may affect implant fixture fractures. Methods: Patients who experienced implant fixture removal at Seoul National University Bundang Hospital from 2007 to 2015 due to implant fixture fracture were included. Implant/crown ratio, time of implant fracture, clinical symptoms before implant fracture, treatment of fractured implants, and the success and survival rate of the replaced implants were evaluated retrospectively. Results: Thirteen implants were fractured in 12 patients. Patient mean age at the time of fracture was 59.3 years. Of the 13 implants, 7 implants were placed at our hospital, and 6 were placed at a local clinic. The mean crown/implant ratio was 0.83:1. The clinical symptoms before fracture were screw loosening in five implants, marginal bone loss in five implants, and the presence of peri-implant diseases in five implants. All the fractured implants were removed, and 12 out of the 13 sites were re-implanted. Parafunctions were observed in two patients: one with bruxism and one with attrition due to a strong chewing habit. Conclusions: Several clinical symptoms before the fracture of an implant can predict implant fixture failure. Therefore, if these clinical symptoms are observed, appropriate treatments can be taken before more serious complications result.

A Study on the Shear Bond Strength of the Reinforced Composite Resin to Dental Alloys (강화형 복합레진과 수종의 치과용 합금간의 전단결합강도에 관한 연구)

  • Kim, Jung-Hee;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.113-122
    • /
    • 2000
  • The reinforced composte resin as the esthetic operative material continuously has been studied because the porcelain fused metal prosthesis is widely used for its excellent esthetics, rigidity and marginal integrity, but it has low fracture resistance against the tensile strength and stress, attrition of the opposite teeth. The reinforced composite resin is well adapt with the dental alloy but it is low the shear bond strength with the dental alloy vs the porcelain fused metal prosthesis, and then has been studied continuously. The purpose of the study was to examine how metal was the higher shear bond strength among the dental alloy was used to the reinforced composite resin and to find the effect that the particle size of sandblasting influenced the shear bond strength. We built up the reinforced composite resin with 4 mm in diameter, 3 mm in height on circular alloy with 5 mm in diameter, 2 mm in height. Type II gold, type IV gold, and Ag-Pd alloy was used as alloys and $50{\mu}m$, $110{\mu}m$, $250{\mu}m$ of the particle size was sandblasted at each alloy in bonding between alloy and resin. We made 90 secimens of 10 per each group and we measured the shear bond strength using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The obtained results were as follows : 1. In comparison among each alloys, Ag-Pd alloy had the highest shear bond strength and the shear bond strength was decreased significantly in the sequence of the type II gold and type IV gold(P<0.001). 2. In comparison according to the size of sandblasting particle, (1) In Ag-Pd alloy, shear bond strength was decreased in the sequence of $110{\mu}m$, $250{\mu}m$, $50{\mu}m$ and there were significant difference in all the group. (P<0.05) (2) In type II gold, it was decreased in the sequence of $250{\mu}m$, $50{\mu}m$, $110{\mu}m$ and there were significant difference. (P<0.05) (3) In type IV gold, it was decreased in the sequence of $110{\mu}m$, $50{\mu}m$, $250{\mu}m$. There were significant difference between the group of $110{\mu}m$ and $50{\mu}m$, the group of $110{\mu}m$ and 250, but there were no significant difference in the group of $50{\mu}m$ and $250{\mu}m$. 3. The highest shear bond strength according to the size of sandblasting particle was $110{\mu}m$ in Ag-Pd alloy and type IV gold, $250{\mu}m$ in type II gold.

  • PDF