• 제목/요약/키워드: Dental Implant-Abutment Connection

검색결과 95건 처리시간 0.023초

심미가 중요시되는 임플란트 치료시 타이타늄 링크-캐드캠 지르코니아 지대주 사용의 임상적 고려 (Clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas)

  • 김종엽
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.123-133
    • /
    • 2016
  • Currently increasing use of implants, especially in anterior implant esthetics has become a major concern for both the patient and dentist. In the case of thin biotype if the thickness of the gingival soft tissue is less than 2mm, human eye can detect differences of colors depends on underlying materials. The zirconia abutment can be use not only for better esthetics but also for the hygienic because it is less attractive for the plaque deposition when it compare to the metals. Zirconia itself has many advantages as a biomaterial but also has frequent mechanical problems when it use for abutment of internal connection implant. For prevention or reduction of mechanical failures, use of titanium-link with zirconia super-structure which part that connects directly into the implant can be a good alternative. In this literature, I would like to review the clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas.

  • PDF

임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용 (Considerations and clinical appliances of various abutments in implant prostheses)

  • 박성우;김선재;장재승
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구 (Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force)

  • 이용우;장용훈
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • 제14권4호
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

임플란트와 상부구조물 사이의 micromotion에 관한 연구 (A study on the micromotion between the dental implant and superstructure)

  • 김지혜;송광엽;장태엽;박주미
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

치과용 임플란트 시스템의 기계적 가공오차에 관한 연구 (Machining Tolerance of Various Implant Systems and their Components)

  • 김형섭;권긍록;한중석
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.57-65
    • /
    • 2008
  • 연구목적 : 본 연구에서는 rotational freedom을 측정할 수 있는 기구를 개발하여 시중에서 유통되고 있는 국산 임플란트 및 다양한 국적의 임플란트들의 기계적인 가공오차들을 측정하여 다양한 임플란트 시스템의 component간의 기계적인 안정성을 평가하고자 한다. 또한 본 연구에서는 더 나아가 최근에 임플란트 abutment로 각광을 받고 있는 각종 ceramic abutment의 절삭 가공오차에 관한 항목을 측정하여 임플란트 제조사 및 임상의들에게 올바른 정보를 제공하고자 한다. 연구재료 및 방법 : 국내에서 유통되는 외부연결구조의 외국산 임플란트 시스템(Nobel Biocare, Anthorgyr)과 국산 시스템(Neobiotec)과 내부연결구조의 임플란트 시스템(외국산:Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply, 국산:Dentium) 별로 임플란트 fixture, abutment, analog를 서로 교차 연결하여 회전각도측정기(rotational angle measuring device)로 freedom of rotational angle을 측정하였다. 국산 외부연결구조의 지르코니아 abutment(ZirAce)를 외부연결구조의 임플란트 시스템(Neobiotec, Nobel Biocare, Anthorgyr)의 fixture와 analog와 교차연결하여 freedom of rotational angle을 측정하였다. 연구결과 : 국산 외부연결구조의 임플란트 시스템은 약 2.67도(fixture와 abutment 연결시), 내부연결구조의 임플란트는 약 4.3도(fixture와 abutment 연결시)의 rotational freedom을 보였다. 국산 지르코니아 abutment는 외국산 및 국산 외부연결구조 임플란트 시스템과 상관없이 3도 이하(fixture와 연결시)의 결과를 보였다. 결 론 : 시제품으로 제작된 디지털 회전각도측정기는 높은 분해능을 갖고 있었으며, 국산 임플란트의 기계적 가공오차는 외국산 임플란트와 거의 유사했다. 국산 세라믹 abutment의 기계적 가공오차는 fixture 제조회사별로 다르게 나타났지만 같은 회사의 절삭가공된 금속 abutment와 비교시 가공오차가 더 적었다.

수종의 내측연결 임플랜트 시스템에서 고정체-지대주-나사계면의 적합에 관한 연구 (Fit of Fixture/Abutment/Screw Interface of Internal Connection Implant Systems)

  • 심덕보;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.283-298
    • /
    • 2008
  • 이 연구의 목적은 내측연결 임플랜트 시스템의 고정체-지대주-나사간의 계면 적합도를 알아보기 위한 것이다. 실험에 이용된 임플랜트 시스템은 Certain, Xive, Replace, Ankylos, SSII 이다. 이 시스템의 고정체와 지대주를 제조사의 권장 토크로 조인후 액상의 불포화 폴리에스터 용액에 고정한 후 절단하였다. 모든 표본은 절단, 연마후 주사전자 현미경으로 관찰하였다.내측연결 시스템의 적합도를 관찰한 결과, 각 제조사들 사이에 차이는 있으나 대부분의 내측연결 시스템의 경우엔 고정체와 지대주의 접촉은 긴밀히 접촉하는 경향을 가지고 있음을 알 수 있었다. 그러나 지대주와 나사, 고정체와 나사 간에는 다양한 형태의 틈이 존재하였다. 이러한 틈들이 나사의 불안정, 미생물의 군집, 악취 등에 어떠한 영향을 미칠지는 앞으로 계속적인 연구가 필요할 것으로 사료된다.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).