• Title/Summary/Keyword: Dental Implant System

Search Result 330, Processing Time 0.019 seconds

Calculation of the Impact Force Applied on the Tooth of Upper and Lower Jaw-Bones in Masticating for the Design of a Dental Implant System. (MDO기법에 의한 임프란트설계에서 요구되는 저작시 상.하악골치아사이의 충격력 계산)

  • 권영주
    • Korean Journal of Computational Design and Engineering
    • /
    • v.7 no.1
    • /
    • pp.27-33
    • /
    • 2002
  • MDO(Multidisciplinary Design Optimization) methodology is a new technology to solve a complicate design problem with a large number of design variables and constraints. The design of a dental implant system is a typical complicate problem, and so it requires the MDO methodology. Actually, several analyses such as rigid body dynamic analysis and structural stress analysis etc. should be carried out in the MDO methodology application to the design of a dental implant system. In this paper, as a first step of MDO methodology application to the design of a dental implant system, the impact force which is applied on the tooth in masticating is calculated through the rigid body dynamic analysis of upper and lower jaw-bones. This analysis is done using ADAMS. The impact force calculated through the rigid body dynamic analysis can be used for the structural stress analysis of a dental implant system which is needed for the design of a dental implant system. In addition, the rigid body dynamic analysis results also show that the impact time decreases as the impact force increases, the largest impact force occurs on the front tooth, and the impact force is almost normal to the tooth surface with a slight tangential force.

External vs internal connection implant system (External vs internal implant : 각각의 장점과 고려사항)

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

디지털 가이드 시스템과 사전 제작된 임플란트 상부보철물을 이용한 전치부의 임플란트 수복 : 증례보고

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2021
  • Dental implant have been in use for a long time to restore at missing tooth. But, To place dental implant at good position very is difficult. Improperly positioned dental implants make some problems to have a good function of dental implant. so, To place dental implant at accurate position is the most important step throughout the whole process. Digital guided system of dental implant is very useful to have a accurate position of dental implant and it makes upper restoration more esthetic and funcional.

COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH (골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교)

  • Kwon Young-Sook;Hwang Sun-Hong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

Multicentric retrospective clinical study on the clinical application of mini implant system (미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구)

  • Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin;Kim, Un-Kyu;Moon, Kyung-Nam;Jeon, Seung-Joon;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

Biomechanical Complications : Fracture and Screw loosening (Biomechanical Complications : 파절과 나사풀림)

  • Kim, Tae in
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.307-317
    • /
    • 2015
  • Although the long-term success of osseointegrated endosseous implants for the support of fixed dental prostheses has been reported, the increasingly widespread use of implant-supported prostheses has led to problems associated with their structural integrity. The most common biomechanical complications observed in dental implant treatment are fracture and screw loosening. The nature of loosening or fracture of dental implant components is complex, since it involves fatigue, fitness, and varied chewing patterns and loads. To assess the service life of the components of the prosthetic system, a knowledge of the loads transmitted through the system is necessary. Design of the final restoration and occlusion in relation to the geometry of a prosthetic restoration has a great influence on the mechanical loading of the implant. It is proposed that control of force in oral cavity may play a larger role in failures than previously believed. Based on theoretic consideration and clinical experiences with dental implant, this article gives simple guidelines for controlling these loads.

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

Assist works as to implant system which dental hygienists perform in a clinical field (Implant system에 있어서 치과위생사의 assist work)

  • Nam, Yong-Ok;Kim, Sun-Sook;Kim, Min-Ja;Ju, On-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.147-163
    • /
    • 2009
  • This study was attempted in order to look into 'Assist work' as to Implant system which dental hygienists perform in a clinical field. Subjects of this research were 362 dental hygienists who work at general hospital, University hospital, dental hospital, and dental clinics located in Seoul, Kyeong-gi, In-chon, and Jeon-buk area. As to research tool, we produced questionnaire which was comprised of the total 25 items regarding 3 of general features (age, career of dental hygienist, and personality), 6 of implant system assist work, 3 of Informed consent before surgery, 6 of preoperative preparation and maintenance related business, and 7 items related to postoperative maintenance. By using SPSS program, collected data was analyzed. Results of analysis in this study were as follow; 1. As to implant related education, dental hygienists' experience of education was high as 77.7%, and the people who is needed more education was 86.3%. Consequently, dental hygienists' concern about the implant related education was very high. 2. It was observed that most of informed consent making approvement by announcement to the surgical operation was made by dental hygienist before implant as 95%. 3. Over 80% of dental hygienists performed acquisition of cleanliness technology, motivation, back up articles preparation, treatment area arrangement, and etc. which we can check by preoperative maintenance items. In particular, response about the motivation was very high as more than 90%. 4. When performing an operation, in the case of disinfecting finger was low for 53.9% and the method was mainly washing with drug solution, and gown sterilization was performed only in 52.2%. Therefore education regarding disinfection was urgently needed. 5. Significance of education could be known that answers of hygienists experienced education appeared highly in items of maintenance method and there was statistically significant difference(p<0.05). 6. In case that assist work were 21cases or greater, agitation measurement was the most many performed in 68.9% and difference was showed up significantly(p<0.001). 7. Evaluation about periodontal tissue was high in dental hygienists who had experienced education and also there was statistically significant difference. In conclusion, assist work of dental hygienists was very comprehensive when implant surgery was performed, and all of items excluding hand disinfection or gown disinfection were highly showed up in most of hygienists. However, since there is the limit that we didn't investigate the quality of performing contents. It is considered that further study regarding the content has to be progressed for supporting this result in the future.

  • PDF

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

Evaluation of fitness in implant screw as tightening torque in dental laboratory (기공실에서의 임플란트 토크값에 따른 적합도 평가)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.310-315
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the tightening torque for dental implant in dental laboratory and to analyze of the effects of different tightening torque. Materials and Methods: The tightening torque for dental implant in dental laboratory were measured by digital torque gauge. The length of abutment and analog were measured as tightening torque of manufacturer's instructions and the measured value. And the data were statically analyzed. Results: The mean tightening torque of implant screw in dental laboratory was $1.563{\pm}0.332Ncm$. The external type implant system of total length were showing no significant differences but the internal type implant system had difference significant (P < 0.05) when compared with tightening torque. Conclusion: The implant prosthesis should be made under manufacturer's instructions especially as tightening torque of screw. For the fidelity of implant prosthesis, dental technician should learn how to use the torque gauge.