• 제목/요약/키워드: Dental Engineering.

검색결과 1,047건 처리시간 0.029초

자동차용 마찰재에 함유된 세라믹분말의 함량에 따른 마찰특성 (Friction Characteristics of Automotive Friction Materials with Ceramic Powder Contents)

  • 이용진;류재경;김택남
    • 한국재료학회지
    • /
    • 제19권7호
    • /
    • pp.403-406
    • /
    • 2009
  • The friction characteristics of automotive brake friction materials that contained different ceramic content were investigated. Several kinds of raw materials, such as resin-based binder, reinforcing fiber, friction restraint, abrasive, and filling materials were mixed, pressed, and heated in order to make the brake friction materials. The contents of SiC and $BaSO_4$ changed from 5 vol% to 20 vol%, respectively. In addition to this, the content of $Al_2O_3$ adjusted from 1 vol% to 16 vol%. The surface morphology of the SiC containing sample appeared rough while more debris was observed when the contents of SiC increased. This implies that the SiC containing brake composite was not adequate for the automobile. However, the relatively smooth surface was observed in samples that contained the $Al_2O_3$. But the roughness was low with a content of 11 vol% $Al_2O_3$ compared to the other samples. This is consistent with the abrasive properties of the samples. In the case of $BaSO_4$ containing samples, the smoothes surface was observed in the contents of 15 vol% $BaSO_4$. Thus, it was concluded that the 11 vol% $Al_2O_3$ and 15 vol% $BaSO_4$ containing composite would be the optimum content for the brake composite. Similar to the results of the surface morphology, the abrasion resistance consistently decreased when the content of SiC increased. On the contrary, the sample that contained 11 vol% $Al_2O_3$ and 15 vol% $BaSO_4$ showed the highest abrasion resistance compared to the other samples.

흉터 치료 촉진 효과를 갖는 치아 케어용 LED 모듈 개발과 광학적특성 분석 (Development of LED Module for Tooth Care with Effect of Promoting Scar Treatment and Analysis of Optical Properties)

  • 유균만;손정현;조현민;강소희;강성수;박성준
    • 한국산업융합학회 논문집
    • /
    • 제23권4_2호
    • /
    • pp.701-708
    • /
    • 2020
  • In this paper, we analyzed the optical properties of the LED module for dental care, which has the effect of promoting cell regeneration and scar treatment. The LED module is a U-shaped module suitable for the shape of teeth. It is manufactured with an LED module (632 nm) and an LED module (632 nm + 870 nm), analyzes the results of optical properties, sets the irradiation distance, irradiation time, and is effective in healing skin wounds. Evaluation was conducted. It was tested in 6 test groups according to the light irradiation conditions, and light was irradiated to the scar site every other day for 7 days, 1 day and 3 days. As a result, it was confirmed that the effect of scar treatment was the highest when the combined wavelength of 632 nm + 870 nm was irradiated in pulse mode than when the single wavelength was irradiated and the composite wavelength was continuously irradiated. In group C group irradiated with PW Mode: pulse mode (period 36 ms, pulse width 35 ms) using a composite wavelength with LED module (632 nm + 870 nm) than group A without light irradiation, the length of scar reduction was 19 %, the area of the scar was further reduced by 10%, and it was confirmed that it is effective in treating scars in the wound area.

홍삼박 n-hexane 추출물의 충치를 유발하는 Streptococcus mutans 저해 효과 (Inhibitory effect of n-hexane extract from Korean red ginseng marc against Streptococcus mutans causing dental caries)

  • 김동청;인만진
    • Journal of Applied Biological Chemistry
    • /
    • 제64권4호
    • /
    • pp.357-362
    • /
    • 2021
  • 본 연구에서는 홍삼의 항충치 효과를 조사하기 위하여 홍삼박 n-hexane 추출물의 충치 원인균 Streptococcus mutans에 대한 항균 효과, 균체 부착과 생물막 생성 저해 효과를 측정하였다. 홍삼박 n-hexane 추출물의 농도에 비례하여 S. mutans의 생육이 저해되었으며, 125 ㎍/mL 이상의 농도에서는 거의 관찰되지 않았다(MIC=125 ㎍/mL). 홍삼박 n-hexane 추출물이 세포막에 작용하여 세포의 핵산 성분이 유출시키는 것으로 나타났다. 그리고, 홍삼박 n-hexane 추출물은 125 ㎍/mL 이상의 농도에서 S. mutans의 부착과 생물막 형성을 90% 이상 저해하였다. GTase 활성은 50 ㎍/mL 농도에서 완전히 저해되었다. 결론적으로 홍삼박 n-hexane 추출물은 S. mutans의 생육과 생물막 형성을 공통적으로 저해하는 것으로 나타났다.

Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

  • Abdullah, Adil Othman;Hui, Yu;Sun, Xudong;Pollington, Sarah;Muhammed, Fenik Kaml;Liu, Yi
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.65-74
    • /
    • 2019
  • PURPOSE. To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS. 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS. Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions ($1.05{\pm}0.24{\mu}m$, $1.30{\pm}0.21{\mu}m$) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions ($30.97{\pm}3.12MPa$, $29.09{\pm}4.17MPa$), while group SLV recorded the lowest ($23.96{\pm}3.60MPa$, $22.95{\pm}3.68Mpa$) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION. GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.

일축인장시험을 통한 투명교정장치용 고분자 소재의 역학적 특성 분석 (Analysis of Mechanical Properties of Polymer Material for Clear Aligner using Uniaxial Tensile Test)

  • 정지영;제태진;전은채
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.64-69
    • /
    • 2018
  • Clear aligners are popular in the field of dental orthodontic treatment because they offer a discreet alternative to braces due to their use of transparent materials. They are formed from flat transparent polymer materials by hot pressed molding. It is necessary to know the mechanical properties of the polymer materials to be able to form the exact shapes of the clear aligners. However, this information is not publicly available. In this study, we present a method to reliably measure the mechanical properties of clear aligner polymer materials and analyze the factors effecting these mechanical properties. First, we surveyed standards related to the mechanical properties of polymer materials to obtain reliable data. Consequently, ISO 527 was selected for use in this study because of the size and thickness of the flat transparent polymer material. The uniaxial tensile tester was constructed and it was verified whether displacement of a crosshead could be regarded as a displacement of gauge-length by optical analysis. Uniaxial tensile tests of three thicknesses from three different companies were performed and each engineering stress-strain curve was measured. Tensile strengths and elastic moduli were obtained by analysis of the stress-strain curves. The tensile strength and elastic modulus of ISO 527 was found to be approximately 50MPa and 2.3GPa, respectively. Both values showed material and thickness dependency.

영유아기 과잉치의 임상적 처치 및 micro-computed tomography 분석: 증례 보고 (Clinical Management and Micro-Computed Tomography Analysis of Supernumerary Teeth in Infancy: A Case Report)

  • 나채현;이한아;김한성;김지훈
    • 대한소아치과학회지
    • /
    • 제49권3호
    • /
    • pp.348-356
    • /
    • 2022
  • 과잉치는 치판의 과도한 성장과 분화에 의해서 발생된다. 이로 인해 이소맹출, 맹출지연, 인접치의 치근 흡수, 그리고 치간이개 등의 문제가 발생할 수 있다. 영유아기에서의 과잉치는 드물며 국내에서는 거의 보고되지 않았다. 이 증례에서는 3개의 매복된 과잉치가 있는 생후 2일된 신생아에 대해 보고하고 있으며, 환자는 21개월간 추적 관찰되었다. 유치열기에 맹출된 하나의 과잉치는 14개월이 되었을 때 중등도 진정 하에 발치되었다. 발치된 과잉치에 대해 micro-computed tomography (CT) 분석을 진행하여 치근단 부위의 미세한 형태 이상을 확인하였다. 과잉치 발치 후 치간이개는 감소하였고 구강위생도 개선되었다. 조기 진단 및 치료를 통해 과잉치로 인한 합병증을 예방할 수 있다.

한국 의료기기 산업의 역사와 국제 경쟁력 고찰 (A Study on the History of the Korean Medical Device Industry and its Global Competitiveness)

  • 염호준;정현우;박상수
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.1-7
    • /
    • 2022
  • 한국의 의료기기 산업은 1995년부터 시작된 G7 의료공학기술개발사업으로 본격적인 성장과 발전의 기틀을 마련하였으며 2020년 한국 의료기기 생산실적은 2001년에 비하여 8.52배, 수출 실적은 13.94배 성장하였다. 의료기기 국산화 개발 초기에 초음파 의료기기 등 전자 의료기기의 개발이 활발하였던 것과 비교하여 2020년에는 체외진단시약과 치과용 임플랜트의 생산 및 수출 실적이 상위권을 차지하고 있다. 그러나 한국 의료기기 시장에서 수입 의료기기가 차지하는 비중은 60-70%에서 큰 변화가 없는데 이는 한국의 의료기기 산업이 중저가 의료기기를 생산 수출하고, 기술집약적이고 자본집약적인 고가 의료기기는 주로 수입에 의존하고 있기 때문이다. 본 논문에서는 한국과 세계시장의 주요 의료기기 회사들의 생산 품목을 비교하여 한국 의료기기 산업의 세계 시장 진출에 대한 전략을 제시하고자 한다.

하이드록시아파타이트/포스터라이트 복합분말의 분사코팅에 의한 3Y-TZP 기판의 표면개질과 생체활성 증진 (Surface Modification and Bioactivity Improvement of 3Y-TZP Substrate by Spray Coating of Hydroxyapatite/Fosterite Composite Powder)

  • 윤유현;이종국
    • 한국재료학회지
    • /
    • 제33권8호
    • /
    • pp.337-343
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals) ceramics have excellent mechanical properties including high fracture toughness, good abrasion resistance as well as chemical and biological stability. As a result, they are widely used in mechanical and medical components such as bearings, grinding balls, and hip implants. In addition, they provide excellent light transmittance, biocompatibility, and can match tooth color when used as a dental implant. Recently, given the materials' resemblance to human teeth, these ceramics have emerged as an alternative to titanium implants. Since the introduction of CAD/CAM in the manufacture of ceramic implants, they've been increasingly used for prosthetic restoration where aesthetics and strength are required. In this study, to improve the surface roughness of zirconia implants, we modified the 3Y-TZP surface with a biocomposite of hydroxyapatite and forsterite using room temperature spray coating methods, and investigated the mixed effect of the two powders on the evolution of surface microstructure, i.e., coating thickness and roughness, and biological interaction during the in vitro test in SBF solution. We compared improvement in bioactivity by observing dissolution and re-precipitation on the specimen surface. From the results of in vitro testing in SBF solution, we confirmed improvement in the bioactivity of the 3Y-TZP substrate after surface modification with a biocomposite of hydroxyapatite and forsterite. Surface dissolution of the coating layer and the precipitation of new hydroxyapatite particles was observed on the modified surface, indicating the improvement in bioactivity of the zirconia substrate.

Biomineralization of three calcium silicate-based cements after implantation in rat subcutaneous tissue

  • Ranjdar Mahmood Talabani;Balkees Taha Garib;Reza Masaeli;Kavosh Zandsalimi;Farinaz Ketabat
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.1.1-1.13
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the dystrophic mineralization deposits from 3 calcium silicate-based cements (Micro-Mega mineral trioxide aggregate [MM-MTA], Biodentine [BD], and EndoSequence Root Repair Material [ESRRM] putty) over time after subcutaneous implantation into rats. Materials and Methods: Forty-five silicon tubes containing the tested materials and 15 empty tubes (serving as a control group) were subcutaneously implanted into the backs of 15 Wistar rats. At 1, 4, and 8 weeks after implantation, the animals were euthanized (n = 5 animals/group), and the silicon tubes were removed with the surrounding tissues. Histopathological tissue sections were stained with von Kossa stain to assess mineralization. Scanning electron microscopy and energy-dispersive X-ray spectroscopy (SEM/EDX) were also used to assess the chemical components of the surface precipitates deposited on the implant and the pattern of calcium and phosphorus distribution at the material-tissue interface. The calcium-to-phosphorus ratios were compared using the non-parametric Kruskal-Wallis test at a significance level of 5%. Results: The von Kossa staining showed that both BD and ESRRM putty induced mineralization starting at week 1; this mineralization increased further until the end of the study. In contrast, MM-MTA induced dystrophic calcification later, from 4 weeks onward. SEM/EDX showed no statistically significant differences in the calcium- and phosphorus-rich areas among the 3 materials at any time point (p > 0.05). Conclusions: After subcutaneous implantation, biomineralization of the 3-calcium silicate-based cements started early and increased over time, and all 3 tested cements generated calcium- and phosphorus-containing surface precipitates.

Testing and evaluation of the corrosion behavior of Aluminum/Alumina bulk composites fabricated via combined stir casting and APB process

  • Abdalkareem Jasim;Ghassan Fadhil Smaisim;Abduladheem Turki Jalil;Surendar Aravindhan;Abdullah Hasan Jabbar;Shaymaa Abed Hussein;Muneam Hussein Ali;Muataz S. Alhassan;Yasser Fakri Mustafa
    • Advances in materials Research
    • /
    • 제12권4호
    • /
    • pp.263-271
    • /
    • 2023
  • In this study, AA1060/Alumina composites were fabricated by combined stir casting and accumulative press bonding (APB). The APB process was repeated up to six press bonding steps at 300Ċ. As the novelty, potential dynamic polarization in 3.5Wt% NaCl solution was used to study the corrosion properties of these composites. The corrosion behavior of these samples was compared and studied with that of the annealed aluminum alloy 1060 and versus the number of APB steps. So, as a result of enhancing influence on the number of APB process, this experimental investigation showed a significant enhancement in the main electrochemical parameters and the inert character of the Alumina particles. Together with Reducing the active zones of the material surfaces could delay the corrosion process. Also, at higher number of steps, the corrosion resistance of composites improved. The sample produced after six number of steps had a low corrosion density in comparison with high corrosion density of annealed specimens. Also, the scanning electron microscopy (SEM), was used to study the corrosion surface of samples.