• 제목/요약/키워드: Dental CT Image

검색결과 131건 처리시간 0.03초

치과용 CT영상의 3차원 Visualization을 위한 Segmentation에 관한 연구 (A Study of Segmentation for 3D Visualization In Dental Computed Tomography image)

  • 민상기;채옥삼
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(3)
    • /
    • pp.177-180
    • /
    • 2000
  • CT images are sequential images that provide medical doctors helpful information for treatment and surgical operation. It is also widely used for the 3D reconstruction of human bone and organs. In the 3D reconstruction, the quality of the reconstructed 3D model heavily depends on the segmentation results. In this paper, we propose an algorithm suitable for the segmentation of teeth and the maxilofacial bone.

  • PDF

치의학 영상 판독의 기본원리 (Basic principles of interpretation in Dental imaging)

  • 한상선
    • 대한치과의사협회지
    • /
    • 제54권9호
    • /
    • pp.704-711
    • /
    • 2016
  • Radiologic images in dentistry are essential to perform the diagnosis, treatment, and tracking process of prognosis, thus the ability of accurate evaluation in the diagnostic images is requested for dental clinician. Radiologic interpretation means recognition of a normality and an abnormality and to report the possible diagnosis and differential diagnosis list. Therefore, dental clinicians should be familiar with the basic principle of interpretation of intraoral and extraoral radiographic images primarily used in dental clinics. Recently, dental cone beam CT is widely used for diagnositc process, thus understanding the three dimensional images is requested. The objective of this manuscript is to help the dental clinicians to interpret accurately the diagnostic images by introducing the basic principles of the step by step analytic process in the appearance of a lesion.

  • PDF

The ability of panoramic radiography in assessing maxillary sinus inflammatory diseases

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • 제38권4호
    • /
    • pp.209-213
    • /
    • 2008
  • Purpose : To evaluate the relative diagnostic accuracy of panoramic radiography and Water's projection in maxillary sinus inflammatory diseases by comparing the radiodensities of the images with those of CT. Materials and Methods : Panoramic radiographs, Waters' projection, and CT images from 55 subjects (11O sinuses) were included in this retrospective study. The radiodensity of each maxillary sinus in panoramic radiography was recorded separately as upper and lower divided horizontally by hard palate. In Waters' projection, the overall sinus radiodensity was recorded. The CT images were considered as gold standard. Results : In panoramic radiography, 83 sinuses had same upper and lower radiodensity and 72 of these were consistent with those of CT, 26 sinuses had different upper and lower radiodensity and 15 of these, upper radiodensity was consistent with CT, the remaining 11, lower radiodensity was consistent with CT. One sinus had upper radiolucency with lower radiopacity and both were consistent with those of CT. Altogether 73 (66.4%) among 110 sinuses in panoramic radiography showed full agreement with CT, 26 (23.6%) showed partial agreement with CT. 9 sinuses had no lower image under the hard palate in panoramic radiography due to the smaller size of sinus. In Waters' projection, the radiodensity of 105 sinuses (95.5%) were consistent with that of CT. Conclusion : The panoramic radiography showed 90.0% of the sinus conditions fully or partially which may appear less accurate than that of Water's view (95.5%) but with more detailed information of the inferior part of sinuses. (Korean J Oral Maxillofac Radiol 2008; 38 : 209-13)

  • PDF

Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가 (Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT)

  • 손상준;박장필;김민정;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.107-114
    • /
    • 2014
  • 목 적 : 두경부 치료계획 CT영상에서 dental implant로 인한 metal artifact 발생 시 O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands)를 적용할 수 있을지 여부를 평가하고자 한다. 대상 및 방법 : 모든 CT영상은 Brilliance Big Bore CT(Philips, Netherlands)에서 관전압 120kVp, 2mm 두께로 촬영하였으며, O-MAR를 이용하여 Metal artifact reduction 후 전산화치료계획장비(Eclipse ver 10.0.42, Varian, USA)로 원본영상과 비교, 분석하였다. O-MAR의 기본적인 성능 테스트를 위해 Metal artifact가 발생하지 않은 영상과 발생한 영상에서 O-MAR 적용시, HU 변화를 검증하기 위해 원통형 팬텀과 cerrobend 막대, 불균질 팬텀을 이용하여 실험하였다. 각각의 원본 영상과 O-MAR 적용 영상에서 관심영역 내 HU 변화를 측정하였다. 이를 바탕으로 본 연구의 주목적인 dental implant로 인한 metal artifact 발생 영상을 재현하기 위해 팬텀을 제작하여 사용하였고, 실제 임상 환자 영상에 O-MAR를 적용한 영상과 원본 영상 그리고 artifact 부분을 보정한 영상의 선량 분포를 SNC Patient(Sun Nuclear Co., USA)로 비교하였다. 결 과 : 두경부에서의 metal artifact를 재현한 원본 영상과 O-MAR 적용영상의 선량 분포를 비교한 결과 gamma passing rate 는 2 mm / 2% 기준으로 99.8%, 일치를 보였다. 실제 임상 환자 영상을 바탕으로 O-MAR 적용 전후 영상과 density corrected CT 영상에 동일한 조건으로 치료 계획을 수립하여 선량 분포를 비교한 결과는 98.5% 일치로 비교적 높은 gamma passing rate를 보였다. 전체적인 선량 분포 차이는 모두 2% 이내로 팬텀 실험과 실제 임상 환자 영상 실험에서 비슷한 결과로 나타났다. 하지만 선량 편차가 적더라도 국소적으로 집중되어 있는 것은 문제의 소지가 될 가능성이 있다. 화질 개선 면에서는 모든 실험에서 O-MAR 적용영상이 원본에 비해 개선됨을 알 수 있었으나, 두경부 metal artifact를 재현한 팬텀 영상 air cavity 내에서 최대 HU 값이 상승하는 경우가 생겼고, 환자 영상에서는 air cavity가 tissue로 잘못 보정되는 경우 또한 발견할 수 있었다. 결 론 : 업체에서 제시한 사용제한 사항인 피부 근처와 저밀도 영역이 공존하는 두경부에서 O-MAR의 사용 가능성을 확인해 본 결과, 원본의 왜곡과 보정이 동시에 일어났다. 심지어 팬텀 실험보다 더 심한 artifact가 생긴 환자의 경우 air cavity가 tissue로 잘못 보정되는 경우도 발생하였다. 결과적으로 아직까지는 O-MAR 알고리즘이 air cavity와 photon starvation artifact를 정확히 구분하지 못하는 것으로 보인다. 선량 측면에서의 영향은 임상에서 배제될 만큼 큰 차이를 보이지는 않았다. 임상에서 원본과 O-MAR 적용 영상을 비교하며 작업한다면 contouring, artifact 보정작업, DRR 화질 개선 등에 도움을 받을 수 있을 것으로 사료된다.

정상 이하선의 전산화단층사진상의 프랙탈차원에 관한 연구 (Fractal Dimension of CT Images of Normal Parotid Glands)

  • 이상진;허민석;유동수
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.203-208
    • /
    • 1999
  • Purpose: This study was to investigate the age and sex differences of the fractal dimension of the normal parotid glands in the digitized CT images. Materials and methods: The six groups. which were composed of 42 men and women from 20 s. 40' sand 60' s and over were picked. Each group contained seven people of the same sex. The normal parotid CT images were digitized. and their fractal dimensions were calculated using Scion Image PC program. Results: The mean of fractal dimensions in males was 1.7292(±0.0588) and 1.6329(±0.0425) in females. The mean of fractal dimensions was 1.7617. in young males 1.7328 in middle males, and 1.6933 in old males. The mean of fractal dimensions was 1.6318. in young females 1.6365 in middle females. and 1.6303 in old females. There was no statistical difference in fractal dimension between left and right parotid gland of the same subject(P>0.05). Fractal dimensions in male were decreased in older group(P<0.05) and larger than female in same age group(P<0.05). But fractal dimensions in female had a tendency to decrease in older group but no statistical difference between ages(P>0.05). Conclusions: The fractal dimension of parotid glands in the digitized CT images will be useful to evaluate the age and sex differences.

  • PDF

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

치과병원에서 사용되는 진단영상에 대한 JPEG2000 압축률에 대한 평가 (Evaluation of compression ratios using JPEG 2000 on diagnostic images in dentistry)

  • 정기훈;한원정;유동수;최순철;김은경
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Materials and Methods : Sixty Digora periapical images, sixty panoramic computed radiographic (CR) images, sixty computed tomographic (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent; 2: probably absent; 3: equivocal; 4: probably present; 5: definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 definitely unacceptable; 2: probably unacceptable; 3: equivocal, 4: probably acceptable; 5· definitely acceptable), and then paired t-test was performed. Results : In Digora, CR panoramic and CT images, compressed images up to ratios of 15 : 1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25 : 1. In Digora and CR panoramic Images, compressed images up to ratios of 5 : 1 showed little difference between the original and reconstructed images in subjective assessment of image quality In CT images, compressed images did up to ratios of 10: 1 and in MR images up to ratios of 15 : 1 Conclusion : We considered compression ratios up to 5 : 1 in Digora and CR panoramic images, up to 10 : 1 in CT images, up to 15 : 1 in MR images as clinically applicable compression ratios.

  • PDF

Effects of the cone-beam computed tomography protocol on the accuracy and image quality of root surface area measurements: An in vitro study

  • Chanikarn Intarasuksanti;Sangsom Prapayasatok;Natnicha Kampan;Supassara Sirabanchongkran;Pasuk Mahakkanukrauh;Thanapat Sastraruji;Pathawee Khongkhunthian;Kachaphol Kuharattanachai;Kanich Tripuwabhrut
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.325-333
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.

적응 최적 임계화와 B-spline 적합을 사용한 CT영상열내 치아 분할 (Segmentation of tooth using Adaptive Optimal Thresholding and B-spline Fitting in CT image slices)

  • 허훈;채옥삼
    • 대한전자공학회논문지SP
    • /
    • 제41권4호
    • /
    • pp.51-61
    • /
    • 2004
  • 치과 분야에서 치아가 개별적으로 조작될 수 있는 3차원 치아 모델은 치과 치료와 시술 시뮬레이션을 위해 중요한 요소이다. CT영상으로부터 이러한 치아 모델을 재구성하기 위해서는 각 치아의 경계를 정확하게 분할할 수 있어야 한다. 그러나 기존의 3차원 재구성 시스템에서 사용되는 임계화 방법은 치아들과 치아와 비슷한 밝기의 치조골이 서로 인접해서 나타나는 CT 영상열에서 효율적이지 못하다. 본 논문에서는 CT영상에서 부드러운 치아 경계를 추출하기 위해 B-spline 곡선 적합을 이용한 치아 분할 방법을 제안한다. 성공적인 적합을 위해서 이전 슬라이스의 분할정보와 적응 최적 임계화 방법을 기반으로 한 초기경계 생성방법을 제안한다. 그리고 적합과정에서 이웃한 유사한 물체에 적합되는 것을 줄일 수 있는 유전자 알고리즘을 이용한 B-spline 적합방법을 제안한다. 평가결과 제안된 알고리즘은 개별치아의 경계를 성공적으로 검출하였으며 이를 이용하여 시술과 치료 과정의 시뮬레이션을 위한 치아의 3차원 모델을 정확하고 부드럽게 생성할 수 있음을 보였다.