• Title/Summary/Keyword: Density variation rate

Search Result 279, Processing Time 0.035 seconds

How Many Parameters May Be Displayed on a Large Scale Display Panel\ulcorner

  • Lee, Hyun-chul;Sim, Bong-Shick;Oh, In-suk;Cha, Kyoung-ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.254-259
    • /
    • 1995
  • Large scale display panel(LSDP) is a main component in the next generation main control rooms. LSDP is located at the front of VDU-based operator's workstation and plays an important role in providing operators with overall information of plant status through mimic diagram, text/digit, graph, and so on. A critical matter determined at the first stage of LSDP design is how much information is displayed, because the information density of LSDP affects operator's performance. Many human factors guidelines recommend low information density of displays to avoid degrade of operator's performance, but doesn't provide a useful limit of information density. In this paper, we considered information density as the number of plant parameters and investigated the proper number of plant parameters through a human factors experiment. The experiment with 4 subjects was carried out and response time, error, and heart rate variation as criterion measures were recorded and analyzed. As the results, it is identified that the proper number of parameters in a LSDP is about thirty.

  • PDF

Influence of Corrosion Potential and Current Density on Polarization Curve Variations using Polycarbonate[III]

  • Park, Chil-Nam;Yang, Hyo-Kyung;Kim, Sun-Kyu;Kim, Myung-Sun;Cheong, Kyung-Hoon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • In this study, experiments were carried out to measure the variations in the corrosion potential and current density of polarization curves using polycarbonate. The results were particularly examined to identify the influences affecting the corrosion potential including various conditions such as temperature, pH, catalytic enzyme, and salt. The lines representing the active anodic dissolution were only slightly shifted in the potential direction by temperature, pH, enzyme, and salt. The tafel slope for the anodic dissolution was determined based on the polarization effect with various conditions. The slope of the polarization curves describing the active-to-passive transition region were noticeably shifted in direction. Also, from the variation in the conditions, the optimum conditions were established for the most rapid transformation, including temperature, pH, corrosion rate, and resistance of corrosion potential. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity(Ir/If). The value of Ir/If was then used in measuring the extent of the critical corrosion sensitivity of the polycarbonate. The potentiodynamic parameters of the corrosion were obtained using a Tafel plot.

  • PDF

A Study on the Crystallization of Low Density Polyethylene Microparticles in $n$-Dodecanol Solution ($n$-Dodecanol 용액에서 저밀도폴리에틸렌 마이크로 입자 결정화에 관한 연구)

  • Park, Keun-Ho;Jang, Young-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.306-312
    • /
    • 2011
  • In this study, we are crystallized to the low density polyethylene (LDPE) micro-particles in $n$-dodecanol solution by thermally induced phase separation(TIPS) method. The Low density polyethylene micro-particles is used in a wide variety of polymer coatings and industrial application. The utility of that for a particular application depends on a number of factors such as the particle size and distribution, and chemical composition of the materials. However, there are still needs for new methods of preparation which will provide the structure with unique sizes. The widely used processes for micro-size particles are crystallization method and thermally induced phase separation. TIPS process based on the phase separation mechanism was performed for the LDPE system which undergoes liquid-solid phase separation. Effects of various operating parameters were examined on the structure variation of the particles. Professionality, take-up speed and crystallization rate depended on temperature and concentration of polymer in solution.

ENHANCEMENT OF DRYOUT HEAT FLUX IN A DEBRIS BED BY FORCED COOLANT FLOW FROM BELOW

  • Bang, Kwang-Hyun;Kim, Jong-Myung
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.297-304
    • /
    • 2010
  • In the design of advanced light water reactors (ALWRs) and in the safety assessment of currently operating nuclear power plants, it is necessary to evaluate the possibility of experiencing a degraded core accident and to develop innovative safety technologies in order to assure long-term debris cooling. The objective of this experimental study is to investigate the enhancement factors of dryout heat flux in debris beds by coolant injection from below. The experimental facility consists mainly of an induction heater, a double-wall quartz-tube test section containing a steel-particle bed and coolant injection and recovery condensing loop. A fairly uniform heating of the particle bed was achieved in the radial direction and the axial variation was within 20%. This paper reports the experimental data for 3.2 mm and 4.8 mm particle beds with a 300 mm bed height. The dryout heat density data were obtained for both the top-flooding and the forced coolant injection from below with an injection mass flux of up to $1.5\;kg/m^2s$. The dryout heat density increased as the rate of coolant injection increased. At a coolant injection mass flux of $1.0\;kg/m^2s$, the dryout heat density was ${\sim}6.5\;MW/m^3$ for the 4.8 mm particle bed and ${\sim}5.6\;MW/m^3$ for the 3.2 mm particle bed. The enhancement factors of the dryout heat density were 1.6-1.8.

Phenology of Zostera caespitosa in Tongyeong on the coast of Korea

  • Yoon, Joon-Sik;Kim, Nam-Gil
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.3
    • /
    • pp.121-128
    • /
    • 2021
  • The variations of morphological features, density and biomass of vegetative shoots and characteristics of reproductive shoots of Zostera caespitosa were examined in Tongyeong, Korea. Morphological features such as leaf length, width and sheath length of Z. caespitosa showed significant seasonal variation (p < 0.001). The highest aboveground value was recorded in late spring to summer and the lowest value in winter. Density and biomass also showed seasonal variations. Annual average shoot density and biomass of Z. caespitosa were recorded as 1,223.4 leaf m-2 and 5,956.9 g w.w.m-2, respectively, and had the highest value in June and lowest values in November and January. Reproductive shoots were observed from April (13℃) to June (21℃). Pistils erected outside sheath, anther dehiscing and small embryos were found in April. Mature fruit and released seeds were found in May and June. These results suggest that this species had a high growth rate in late spring and early summer (15℃-20℃). Reproductive shoots of Z. caespitosa may initially appear at about 10℃ in spring and seed have been released at about 20℃ in fall.

Nanostructural Features of nc-Si : H Thin Films Prepared by PECVD (PECVD 기법에 의해 제조된 nc-Si : H 박막의 나노 구조적 특성)

  • 심재현;정수진;조남희
    • Korean Journal of Crystallography
    • /
    • v.14 no.2
    • /
    • pp.56-61
    • /
    • 2003
  • Nanocrystalline hydrogenated silicon (nc-Si : H) thin films were deposited at room temperature by plasma enhanced chemical vapor deposition (PECVD): a mixture of SiH₄ and H₂ gas was introduced into the evacuated reaction chamber. When the H₂ gas flow rate was low, the density of Si-H₃ bonds was high in the films. On the other hand, when the H₂ gas flow rate was high, e.g., 100 sccm, a large number of Si-H bonds contributed to the passivation of the surface of the large volume of Si nanocrystallites. The relative fraction of the Si-H₃ and Si-H₂ bonds in the amorphous matrix varied sensitively with the H₂ gas flow rate. The variation was associated with the change in the intensity as well as the wavelength of the main PL peaks, indicating the change in the total volume as well as the size of the Si nanocrystallites in the films.

A Study for the Output Increament of the Hydrogen Gas Turbine with Water Injection (물분사 수소 가스터빈의 출력 향상을 위한 연구)

  • Jung, K.S.;Oh, B.S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • Most of today's energy supply is obtained from fossil fuels. Despite of high energy density, higher store efficiency and long mileage, fossil fuels cause environmental pollution and their reserves are limited. In this study pure hydrogen gas and oxygen gas are burned without the emission of pollution. A gas turbine is used to obtain power. Water is injected into a combustor, which prevents overheating and recovers cooling heat. Excessively supplied water is recirculated. With variation of mass flow rate and equivalence ratio, the affection of water injection rate and the temperature of injected water on efficiency and power are experimented. Injected water gets cooling heat, is expanded from liquid to vapor and raises the thermal efficiency. It is enable to determine the rate of water injection, which makes the maximum power. The increase of temperature of water injection raises the efficiency of the system.

  • PDF

On the Mismatch Phenomena in DPCM Coding of Speech (DPCM 음성 부호화기의 부정합현상에 관한 연구)

  • Yoo, Deuk Su;Cho, Dong Ho;Un, Chong Kwan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.5
    • /
    • pp.597-604
    • /
    • 1986
  • This paper describes various mismatch phenomena in differential pulse code modulation (DPCM) coding, such as the mismatch effects of probability density functin(pdf), signal variance, and correlation. At a high transmission rate(i.e., above 32 kbits/s), the performance of DPCM can be improved by matching the pdf shape between the input signal and the quantizer. However, the same gain cannot be obtained at a lower transmission rate. Also, it is shown that the gamma quantizer is realtively robust to the variation of pdf shaper and signal variance. Moreover, as the transmission rate increases, the performance of DPCM for the input signal with large variance is worse than that of DPCM for the signal with small variance due to the increase of overload noise. According to our simuladiton results, the mismatch effects of pdf shape and variance appear to yield more degradatin than that of correlation in a DPCM system.

  • PDF

The Studies on the Transaminase Activities(1) (Transaminase 활성에 관한 연구(제 1보))

  • 조영주
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.23-25
    • /
    • 1977
  • Transaminase has been a popular methods in the clinical laboratory for the diagnosis of particular diseases. The methods we are familiar with should be considered further on the serum states provided on the test to be done. (serum freshness, temperature and duration preserved) I have studied transaminase activities of the serum preserved under frozen (-10$\circ$C), refrigerated (4$\circ$C) and room temperature conditions. At a given interval those activities of serum are measured and then the results are compared with the optical density and calculated for the standard deviation and percent variation (Table 1. & Fig. 1.) G.O.T. activity is maintained decreased at a relatively constant rate from 2nd day to 14th day preservation under frozen and refrigerated but its activity variation at 25$\circ$C are far greater than the above conditions throughout the test periods. Elevated G.P.T. level of serum compared with G.O.T. are remained at any temperature and duration. Unless the determination of amino acid level study can not ruled out clearly.

  • PDF

Study on K-factor for temperature variation of working fluid in spray nozzle with orifice (오리피스형 분사노즐에서 작동유체의 온도변화에 따른 K-factor에 관한 연구)

  • Bae, K.Y.;Chung, H.T.;Kim, C.H.;Kim, H.B.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.12-18
    • /
    • 2008
  • In the present study, the numerical simulation has been performed to investigate K-factor for temperature variation of working fluid in spray nozzle with orifice. The commercial CFD software, Fluent with the proper modeling was applied for analyzing the internal of the spray nozzle. Numerical result for K-factor at $20^{\circ}C$ agrees with the experimental result that it applied n=0.5 within about 7% error. The pressure drop inside nozzle is showed 20% passing swirler, 70% in the region between the outlet of swirler and the orifice and 10% at the outlet of orifice. As the operating pressure is increased, K-factor is decreased by effect of flow resistance at it's inlet before pass swirler. The temperature increase of working fluid reduced the flow rate according to reducing of density, and average 1.23% decrease is showed in the present research.

  • PDF