• 제목/요약/키워드: Densities

검색결과 3,438건 처리시간 0.028초

Model-independent test of gravity

  • L'Huillier, Benjamin
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.48.3-48.3
    • /
    • 2020
  • Using redshift-space distortion, I reconstruct the growth history as a smooth function using model independent methods. Assuming general relativity, I obtain the expansion history independently of the dark energy model, and test it to the supernovae data. The results are consistent with general relativity as gravity and the cosmological constant as dark energy, although interestingly negative dark energy densities are not ruled out by the data at z~0.7 to 1.

  • PDF

The Evaluation of Evenness of Nonwovens Using Image Analysis Method

  • Jeong, Sung-Hoon;Kim, Si-Hwan;Hong, Cheol-Jae
    • Fibers and Polymers
    • /
    • 제2권3호
    • /
    • pp.164-170
    • /
    • 2001
  • Authors studied on the applicability of image analysis technique using a scanner with a CCD (charged coupled deviced) to the evaluation of evenness of nonwovens because it has distinctive features to considerably save time and labor in the analysis compared with other classical methods. As specimens fur the experiment, two different types that are unpatterned and patterned ones were prepared. For the unpatterned specimen, webs were chemically bonded, while for the patterned specimen, webs being thermally calendered with engraved roller. Several webs having various areal densities were prepared and bonded. Coefficient of variation (CV%) was used as a parameter to evaluate the evenness. Scanning conditions could be suitably set up through comparing the total variance to the between-group variance and to the within-group variance, respectively, on the images scanned at the different conditions. The 2D convolution method with smoothing filter kernel was introduced to further filter the noises on the scanned images. After the filtering process, the increase of web areal densities gave an uniform decrease of the CV%. This showed that the scanned image analysis with proper filtering process could be successfully applicable to the evaluation of evenness in nonwovens.

  • PDF

다단입자채집기와 입자계수기 자료를 이용한 서울 에어러솔 밀도 계산 (Aerosol Density Determined Using Micro-orifice Uniform Deposit Impactor and Aerosol Dust Monitors Data at Seoul)

  • 김정은;이해영
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.298-304
    • /
    • 2010
  • In order to calculate the aerosol bulk densities of $PM_{1.0}$ and $PM_{10}$, aerosol mass and number concentrations were measured for the period of December 2008~April 2009. $PM_{1.0}$ and $PM_{10}$ mass concentrations were measured using a cascade impactor (Micro-Orifice Uniform Deposit Impactor, MOUDI) while their volume concentrations were calculated based on number concentrations from an environmental dust monitor (EDM). Normal aerosol size distribution fitting functions were retrieved for number size distribution since aerosols < $2.5{\mu}m$ were measured from the EDM. Strong correlation was found between $PM_{1.0}$ mass and volume concentrations obtained with a $R^2$ of 0.95. The calculated average bulk densities of $PM_{1.0}$ and $PM_{10}$ were $1.97{\pm}0.33g/cm^3$ and $2.15{\pm}0.18g/cm^3$, respectively.

Helicobacter pylori 감염 위염에서의 비만세포 증가와 Stem Cell Factor Receptor (c-kit)의 발현 (Mast Cell Increase and Stem Cell Factor Receptor (c-kit) Expression in Helicobacter pylori-infected Gastritis)

  • 제갈승주
    • 대한임상검사과학회지
    • /
    • 제37권1호
    • /
    • pp.41-46
    • /
    • 2005
  • It is known that mast cells (MCs) are increased in H. pylori-infected gastritis and its increase is mediated by stem cell factor (c-kit ligand). To determine the mechanism of mast cell recruitment and activation by stem cell factor, weinvestigated the expression of stem cell factor receptor (c-kit) in H. pylori-positive and -negative gastric mucosa. Biopsy specimens from 16 H. pylori-negative and 20 positive subjects were examined. H. pylori infection in gastric mucosa was examined by the Warthin-Starry method. MC and c-kit were identified by immunohistochemisty, using a monoclonal antihuman MC tryptase antibody and a polyclonal anti-human c-kit antibody. Densities of MC and c-kit positive cell were measured by a computerized image analysis system. MCs were detected in the lamina propria of both H. pylori-positive and -negative gastric mucosa. Densities of MC and c-kit positive cell were significantly greater in H. pylori-positive than -negative subjects. c-kit was located on the surface of MCs. These results indicate that stem cell factors may be one of the factors involved in mast cell increase and that they activate mast cells by binding with c-kit.

  • PDF

Influence of Foaming Agents on the Properties of Foamed Concretes Having Various Densities

  • Kim, Jin-Man;Jeong, Ji-Yong
    • 한국건축시공학회지
    • /
    • 제12권1호
    • /
    • pp.22-30
    • /
    • 2012
  • Four types of foaming agents, including Alcohol Ethoxy Sulfate (AES), Alpha Olefin Sulfonate (AOS), Vegetable Soap (VS), and Fe-Protein (FP), are widely used in the construction field. These have different surface tensions and viscosities in water of the same concentration, affecting the flow speed of liquid, size and distribution of foam, and foam stability. However, there is a lack of data regarding the properties of foam concrete using various foam agents. The purpose of this study is to investigate influence of foaming agents on the properties of foamed concretes with various densities. We find that the foaming agent type has little effect on the density, compressive strength, and thermal conductivity of foam concrete, but considerably affects the unit weight of foam, flow and flexural strength of foamed concrete. While almost all properties of foam concrete are affected by density in fresh or hardened state, the potential energy changed by slurry density and the viscosity of foam are dominant factors in the flowability of foam slurry.

Comparison of Catalytic Activity for Methanol Electrooxidation Between Pt/PPy/CNT and Pt/C

  • Lee, C.G.;Baek, J.S.;Seo, D.J.;Park, J.H.;Chun, K.Y.
    • 전기화학회지
    • /
    • 제13권4호
    • /
    • pp.240-245
    • /
    • 2010
  • This work explored the catalytic effect of Pt in multi-wall carbon nanotube and poly-pyrrole conductive polymer electrocatalysts (Pt/PPy/MWCNT). A home-made Pt/PPy/MWCNT catalyst was first evaluated by comparing its electrochemical active surface area (ESA) with E-Tek commercial catalysts by cyclic voltammetry in $H_2SO_4$ solution. Then, the methanol oxidation currents of Pt/PPy/MWCNT and the hydrogen peaks in $H_2SO_4$ solution were serially measured with microporous electrode. This provided the current density of methanol oxidation based on the ESA, allowing a quantitative comparison of catalytic activity. The current densities were also measured for Pt/C catalysts of E-Tek and Tanaka Precious Metal Co. The current densities for the different catalysts were similar, implying that catalytic activity depended directly on the ESA rather than charge transfer or electronic conductivity.

Fabrication of Inkjet-printed and Non-sintered $BaTiO_3$ Dielectric Film

  • Lim, Jong-Woo;Kim, Ji-Hoon;Kim, Hyo-Tea;Yoon, Young-Joon;Yoon, Ho-Gyu;Kim, Jong-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.80-80
    • /
    • 2009
  • $BaTiO_3$ has high permittivity so that has been applied to dielectric and insulator materials in 3D system-level package integration. In order to achieve excellent performance of device, the $BaTiO_3$ layer should be highly dense. In this study, $BaTiO_3$ thick films were prepared by the inkjet printing method using 4 vol.% $BaTiO_3$ colloidal inks and cured at $28^{\circ}C$ for 5 h after infiltration of polymer resin for non-sintered process using 3 vol.% cyanate ester emulsion ink. From the obtained results. packing density was determined to be improved by overlapping rabbit ears which were generated by coffee ring effect. We also calculated the packing densities of the films and correlated these packing densities to the measured permittivity of the films.

  • PDF

Imperfect Correlation of Mammographic and Clinical Breast Tissue Density

  • Alipour, Sadaf;Bayani, Leila;Saberi, Azin;Alikhassi, Afsaneh;Hosseini, Ladan;Eslami, Bita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3685-3688
    • /
    • 2013
  • Background: Clinicians determine degree of mammographic density based on tissue firmness on breast examination. The study aimed to compare breast density in mammography and clinical breast examination. Materials and Methods: Six-hundred sixty three women 40 years of age or older were studied. The breast exam density was graded from 1 to 4 by two expert surgeons and the mammographic parenchymal density by two expert radiologists. Then for practical reasons, grades 1 and 2 were considered as low-density and grades 3 and 4 as high-density. Results: High and low densities were detected in 84.5% and 15.5% of clinical breast examinations and 59.7% and 40.3% of mammographies, respectively. The statistical analysis showed a significant difference between the breast tissue densities in breast examination with those in mammography. Conclusions: A clinically dense breast does not necessarily imply a dense mammographic picture.

석탄회가 첨가된 점토의 마이크로파를 이용한 소결 (Microwave sintering of Fly Ash substituted body)

  • 김석범;한정환;김유택
    • 한국결정성장학회지
    • /
    • 제8권3호
    • /
    • pp.513-517
    • /
    • 1998
  • 석탄회의 점노를 70:30의 비율로 혼합하여 마이크로파를 이용하여 소결하였으며, 소결에는 2.45Ghz의 일반가정용 마이크로파 오븐을 사용하였다. 시편은 $1,150^{\circ}C$에서 50분까지 10분 간격으로 소결하였다. 석탄회의 미세구조는 주사전자현미경(SEM)과 Energy dispersive spectrometry(EDS)를 이용하여 분석을 하였으며 X선회절 분석과 압축강도와 겉보기 비중을 추정하여 비교하였으며 시간이 지날수록 시편의 기공크기는 작아졌으나 압축강도와 겉보기 비중은 변화의 크기가 작았다. 로안에서의 마이크로파에 의한 시편으로의 열전달현상을 알아보기 위하여 컴퓨터를 이용한 수치해석을 행하였다.

  • PDF

Growth of GaAs Crystal by an Improved VGF Apparatus

  • Chul-Won Han;Kwang-Bo Shim;Young-Ju Park;Seung-Chul Park;Suk-Ki Min
    • 한국결정성장학회지
    • /
    • 제1권1호
    • /
    • pp.17-25
    • /
    • 1991
  • The construction details of VGF apparatus with a DM(direct monitoring) furnace for the growth of low defect crystal and characteristics of GaAs crystal grown by this apparatus are described. The average dislocation densities and EL2 concentration of as-grown undoped GaAs along the different solidified fractions exhibit $4{\times}10^{2}-7{\times}10^{3}cm^{-2}$ and $6{\times}10^{14}-4{\times}10^{15}cm^{-3}$, which are less than those observed for liquid encapsulated Czochralski(LEC) or high-pressure vertical gradient freeze(VGF) crystals. These remarkable reduction of the dislocation densities and EL2 concentrations were explained by the lower temperature gradient ($dT/dx-10^{\circ}/cm$) and slower rates of post - growth cooling ($20^{\circ}C/hr:1240-1000^{\circ}C,\;30^{\circ}C/hr:1000-700^{\circ}C$). Also, The Hall mobilities, carrier concentrations show uniform distribution throughtout 80% of the ingot length.

  • PDF