• Title/Summary/Keyword: Dense-wavelength-division-multiplexing

Search Result 50, Processing Time 0.026 seconds

12.5-GHz interleaved bidirectional ultra-dense WDM transmission using the beat-frequency-locking method (Beat-frequency-locking기술을 이용한 12.5 GHz 채널간격 양방향 초고밀도 WDM 광채널 전송)

  • 이재승;김상엽;서경희
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.351-354
    • /
    • 2003
  • We present a 12.5-GHz interleaved bidirectional ultra-dense wavelength-division-multiplexing transmission over a conventional single mode fiber of 80 km achieving spectral efficiency as high as 0.8-bit/s/Hz. The beat-frequency-locking method is used to stabilize the channel frequency within $\pm$200 MHz error. To facilitate the identification of multiple beat frequency signals, we use a radio-frequency spectrum analyzer. The bidirectional transmission penalty is about 0.3 dB compared with the unidirectional transmission over the same fiber.

Characteristics of active optical ring network and performance evaluation in Bandwidth on Demand (능동형 광 링 네트워크의 특징 및 요구 대역폭에 따른 성능 분석)

  • Lee Sang-Wha;Song Hae-Sang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.209-218
    • /
    • 2005
  • In this paper, we present an Active Optical Network(AON) . The AON uses the Dense Wavelength Division Multiplexing(DWDM) from optical communication access network of ring type, and will be able to provide the smoothly service in the Bandwidth on Demand by using DWDM. It supports the connection of the multiple wavelength and the Sub-Carrier from the optical gigabit ethernet switch. The Wavelength Add Drop Multiplexer(WADM) extracts a specific wavelength, and composes a node of the ring network. The specific wavelength becomes demultiplexing in the Sub-Carrier and it is distributed in the user The active connection of optical gigabit ethernet switch where the distribution of access network is started and access terminal connection equipment is possible. By the BoD from the AON it compares the buffer size which changes, and it analyzes. Also the Time delay of bit compares with the throughput of server The limit of amount of time is decided. Consequently it will be able to realize the dynamic use protocol and an efficient algorithm of the network.

  • PDF

Dense Wavelength-Division Multiplexed Passive Optical Network Employing Wavelength-Locked Fabry-Perot Lasers (파장 고정된 Fabry-Perot 레이저를 사용한 고밀도 파장분할 다중방식 수동형 광통신망)

  • Kim Hyun Deok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • A cost-effective dense WDM-PON employing wavelength-locked Fabry-Perot lasers has been demonstrated. We have successfully demonstrated a dense WDM transmission of 4×622 Mb/s upstream signal with 50-GHz channel spacing over 30-km conventional single mode fiber. We have also investigated the heating noise characteristics of a wavelength-locked Fabry-Perot laser and showed the wavelength-locked Fabry-Perot laser suppresses the intensity noise of the incoherent light injected which enables a dense WDM transmission with a channels spacing of 50 GHz.

Bidirectional Hybrid DWDM-PON for HDTV/Gigabit Ethernet/CATV Applications

  • Lu, Hai-Han;Tsai, Wen-Shing;Chien, Tzu-Shen;Chen, Shih-Hung;Chi, Yu-Chieh;Liao, Che-Wei
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.162-168
    • /
    • 2007
  • A new scheme for bi-directional HDTV/Gigabit Ethernet/CATV transmission over a hybrid dense-wavelength-division-multiplexing passive optical network (DWDM-PON) is proposed and demonstrated. It is based on injection-locked vertical-cavity surface-emitting lasers and distributed-feedback laser diodes as transmitters. Services with 129 HDTV channels, a 1.25 Gbps Gigabit Ethernet connection, and 77 CATV channels are successfully demonstrated over 40 km single-mode fiber links. Good performance of bit error rate, carrier-to-noise ratio, composite second order, and composite triple beat is achieved in our proposed bidirectional DWDM-PON.

  • PDF

Ultra-Dense WDM PON with 12.5-GHz Spaced 256 Channels

  • Yim, Jae-Nam;Hwang, Gyo-Sun;Lee, Jae-Seung;Seo, Kyung-Hee;Lee, Hyun-Jae;Ko, Je-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.351-354
    • /
    • 2008
  • We demonstrate an ultra-dense wavelength-division- multiplexed (UD-WDM) passive optical network (PON) where 12.5-GHz spaced 1 GbE ${\times}$ 256 optical channels are distributed using 12.5- and 200-GHz arrayed waveguide gratings in series. For the generation of upstream signals, we use reflective semiconductor optical amplifiers. We use two optical fiber amplifiers at the optical line terminal to amplify downstream and upstream channels.

A Low Noise Broadband Light Source and its Application on WDM-PON (저잡음 특성의 광대역 비간섭성 광원과 파장 분할 다중방식 수동형 광가입자망에의 응용)

  • Choi Ki-Man;Moon Jung-Hyung;Lee Chang-Hee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.68-76
    • /
    • 2006
  • We propose a low noise broadband light source (BLS) and investigate a cost-effective wavelength division multiplexing-passive optical network (WDM-PON) for the convergence of broadcasting and data service. The proposed BLS is used for an injection light of wavelength-locked Fabry-Perot laser diodes (F-P LD) and helps the color-free operation of dense WDM-PON (DWDM-PON). In addition, we apply this BLS to a optical source for overlay of digital broadcasting channel on the WDM-PON.

Multi-wavelength Conversion Scheme using Fabry-Perot Laser Diode with CFBG external cavity (CFBG 외부 공진기 구조를 갖는 Fabry-Perot 레이저를 이용한 다파장 변환기 구조)

  • 조용상;최우영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.166-167
    • /
    • 2001
  • 과장 변환기는 WDM (wavelength division multiplexing) 시스템에서 wavelength relocation을 가능하게 하여 시스템의 유연성과 효율성을 향상시킨다는 측면에서 매우 중요한 기능을 갖는다. WDM 시스템의 채널의 수가 점차 증가함에 따라 채널의 간격이 100 GHz에 이르고 있으며 향후 더욱 조밀해 질것이다. 이러한 DWDM (Dense WDM)시스템에서 사용될 수 있는 파장변환기는 100 GHz단위의 파장변환 기능과 광대역 가변 변위가 필수적이다. (중략)

  • PDF

QoS-based RWA Algorithm for providing QoS Services in the Next Generation Internet based on DWDM (DWDM 기반의 차세대 인터넷에서 QoS서비스 제공을 위한 QoS-based RWA 알고리즘)

  • 배정현;송현수;김성운;김영부;조기성;이현진
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.12
    • /
    • pp.27-37
    • /
    • 2003
  • In the next generation Internet(NGI) based on dense wavelength division multiplexing(DWDM) technology, QoS RWA considering various QoS parameters of DWDM networks is regard as one of the key issues in providing real-time multimedia services. However, finding a qualified path meeting multi-constraints is generally NP-complete problem. It is insufficient for QoS RWA researches in DWDM networks that must consider QoS parameter as well as wavelength-continuity constraint. This paper proposes qualified path routing (QPR) algorithm with minimum computation and implementation complexity based on flooding method to accomplish QoS routing and wavelength assignment (RWA). We also introduce a QoS-based RWA mechanism considering multi-constraint such as optical signal quality attributes, survivability and wavelength-continuity constraint combined with proposed routing algorithm. Simulation results show superior efficiency of the proposed algorithms in terms of blocking probability, routing overhead and survivability ratio.

Shared Protection of Lightpath with Guaranteed Switching Time over DWDM Networks

  • Chen Yen-Wen;Peng I-Hsuan
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.228-233
    • /
    • 2006
  • Survivability is a very important requirement for the deployment of broadband networks because out of service links can affect volumes of traffic even if it is a very short time. And the data paths of broadband networks, which are critical for traffic engineering, are always necessary to be well protected. The procedure of protection or restoration for a path is initiated when failure is detected within the working path. In order to minimize the influence on transmission quality caused by the failure of links and to provide a definite time for the recovery from the failure, the protection switching time (PST) should be carefully considered in the path arrangement. Several researches have been devoted to construct the protection and restoration schemes of data paths over dense wavelength division multiplexing (DWDM) networks, however, there was rare research on the design of data paths with guaranteed protection switching time. In this paper, the PST-guaranteed scheme, which is based on the concept of short leap shared protection (SLSP), for the arrangement of data paths in DWDM networks is proposed. The proposed scheme provides an efficient procedure to determine a just-enough PST-guaranteed backup paths for a working path. In addition to selecting the PST-guaranteed path, the network cost is also considered in a heuristic manner. The experimental results demonstrate that the paths arranged by the proposed scheme can fully meet the desired PST and the required cost of the selected path is competitive with which of the shared path scheme.