• 제목/요약/키워드: Delta power

검색결과 753건 처리시간 0.036초

원자력발전소의 온배수 배출량을 고려한 어업생산감소율 추정 모델 (A Quantitative Model for Estimating Fishery Production Damages as a Result of Thermal Effluents from Nuclear Power Plants)

  • 장창익;이성일;이종희
    • 한국수산과학회지
    • /
    • 제42권5호
    • /
    • pp.494-502
    • /
    • 2009
  • A quantitative model was developed in order to estimate fishery production damage due to anthropogenically induced environmental changes. The model is described in the following equation, $Y_D=\frac{{\phi}_D}{{\phi}_G}[Y_0{\cdot}(t_p-t_0)-\frac{Y_0}{{\phi}_G}(1-e^{-{\phi}_G(t_p-t_0)})]$, where, $Y_D$ is annual amount of fishery production by nuclear power plant. ${\varphi}$ D and ${\varphi}$ G are instantaneous decreasing coefficient of fishery production by nuclear power plant and instantaneous decreasing coefficient of gross fishery production, respectively. $Y_0$ is annual mean fishery production without damages. $t_p$ is the present time, and $t_0$ is the starting time of damages. The model was applied to fishing grounds near a nuclear power plant on the east coast of Korea. Since fishery production damages have become bigger with increasing emission of thermal effluents from generators activities in the power plant, this factor has also been considered as, $\delta_{D_i}=\delta_D\({\sum}\limits_{i=0}^{n}\;W_i/W_T\)$, where, $\delta_{Di}$ is the cumulative damage rate in fishery production from generators, $\delta_D$ is the total cumulative damage rate in fishery production, $W_i$ is the emission amount of thermal effluents by generator i, and n is the number of generators in the nuclear power plant. This model can be used to conduct initial estimates of fishery production damages, before more detailed assessments are undertaken.

200-MW 모듈레이터의 동작 특성 및 고조파 해석 (Operation Characteristic and Harmonic Analysis of 200-MW Modulator)

  • 박성수;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Zig-zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치의 개발 (New harmonic drop device develop take advantage of Zig-zag TR line and Open Delta mode)

  • 유상봉;이성호;김기성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2004
  • 지금까지의 고조파 필터는 중성선 리액터와 이중 엇갈린 결선으로 영상고조파 전류를 제거하였으나 중성선 리액터 과열로 중성선 단선 위험의 문제가 발생하였다. 본 중성선 Open Delta 방식은 이중 엇갈린 결선의 Core Block내에 결선하여 중성선에 연결하면 중성선으로 흐르는 영상 고조파 분 전류를 과열 없이 안전하게 제거하고 중성선 고조파 부하 전류량에 관계없이 완전하게 제거되는 것을 시험 분석한 결과로 가장 효과적인 고조파 저감 대책을 개선사례로 제시하여 관련선로에 도움이 되고자 한다.

  • PDF

전압안정도 개선을 고려한 적정 부하차단 기법 (A study on the optimal load shedding scheme considering the voltage stability improvement)

  • 이상중;김건중;김원겸;김용배
    • 대한전기학회논문지
    • /
    • 제44권3호
    • /
    • pp.270-273
    • /
    • 1995
  • This paper proposes an optimal load shedding algorithm by which the system loss can be minimized when the load shedding is unavoidable in case of severe contingency such as the outage of key generators or lines. Shedding load .DELTA.S = .DELTA.P + J.DELTA.Q(MVA) is performed on the weakest bus (on the view of voltage stability), step by step, by the priority of the I.DELTA. = SQRT(.lambda.$\_$P/$\^$2/ + .lambda.$\_$Q/$\^$2/) index given for each load bus, where .lambda.$\_$P/ and .lambda.$\_$Q/ are the sensitivity indices representing the system loss variation versus active and reactive power change of the bus load bus. All loads are assumed to be constant power loads for convenience. A 5 bus sample system proves the effectiveness of the algorithm proposed.

$\Delta$ 변환기 후단 처리용 고선형 저전력 연속시간 필터의 설계 (A design of high-linearity low-power contiunous-time filter for post-processing of .SIGMA..DELTA. converters)

  • 홍국태;정현택;손한웅;염왕섭;정강민
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1579-1589
    • /
    • 1997
  • This paper introduces a monolithic chip 3.3V high-performance continuous-tune filter used in a CDP that can reconstruct the PDM or PWM signal output of a .SIGMA..DELTA. D/A converter. We also mentioned an active RC filter structure and filter order satisfying high-linearity and the design specification. In desigining the OP-AMP, using a structure that accepts some distortion we could reduce the chip area, and reducing the DC path using a new biascircuit gave us better power performance. The designed.SIGMA..DELTA. D/A converter post-processing filter does its smoothering operations and reconstructs the data without reducing the performance of the system.

  • PDF

Control of Open-Loop PWM Delta-Connected Motor-Drive Systems under One Phase Failure Condition

  • Sayed-Ahmed, Ahmed;Demerdash, Nabeel A.O.
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.824-836
    • /
    • 2011
  • A new fault-tolerant control topology for open-loop motor-drive systems with Delta-connected stator windings is introduced in this paper. This new control topology enables the operation of a three-phase induction machine as a two-phase machine fed by a three-phase inverter upon a failure in one of the motor phases. This topology utilizes the "open-Delta" configuration to independently control the current in each of the two remaining healthy phases. This new control technique leads to the alleviation of any torque pulsations resulting from the consequences of the asymmetrical conditions associated with this class of faults.

대용량 발전기 고정자 바의 유전정접 특성 (Characteristics of Dissipation Factor in Large Generator Stator Bars)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.402-403
    • /
    • 2009
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 11460h, dissipation factor($tan{\delta}$) test was performed on No. 1 and No.2 model stator bars. The ${\Delta}tan{\delta}$ of No. 1 and No. 2 stator bars increased with increased in aging time.

  • PDF

Combined Dithered Sigma-Delta Modulation based Random PWM Switching Scheme

  • Kim, Seo-Hyeong;Choi, Woo-Jin;Choi, Se-Wan;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.667-678
    • /
    • 2009
  • The PWM (Pulse Width Modulation) control signals have a drawback in that their power spectrum tends to be concentrated around the switching frequency and the resulting harmonic spikes cause an EMI (Electromagnetic Interference) and switching losses in semiconductors, etc. The SDM (Sigma-Delta Modulation) is a type of switching modulation used to reduce these harmonic spikes, and several SDM schemes are investigated in this paper. In the DSDM (Dithered SDM), the SDSDM (Space-Dithered SDM) and TDSDM (Time-Dithered SDM), the signals are classified by the location of their random dither additions. In these schemes, the switching frequency is spread by a random dither generator placed on the input or the output parts. Experimental results are presented where the advantages of the new proposed CDSDM (Combined Dithered SDM) are confirmed by applying to a buck converter.

Sensorless Brushless DC Motor Drive for Frequently Startup

  • Zhou Genfu;Wu Zhigan;Ying Jianping
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.50-56
    • /
    • 2005
  • This paper develops a sensorless BLDCM drive for frequently startup. The position information is based on detecting the zero-crossing point of the BEMF that can be directly obtained from the terminal voltage of the floating phase without voltage-dividing and filtering. As a result, this approach makes it possible to detect the rotor position over a wide speed range, especially at a lower speed. A fast startup procedure is also discussed because the induced BEMF signals are not present when motor is at rest. Experimental results shows that the schemes implemented are feasible and the performance achieved are satisfactory.

발전기 고정자 권선의 가속열화 특성 (Characteristics of Accelerated Aging in Generator Stator Windings)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.279-280
    • /
    • 2008
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 4780h, diagnostic tests were performed on No. 1 and No. 2 model stator bars. Diagnostic tests included AC current, dissipation factor(tan$\delta$) and partial discharge magnitude. The ${\Delta}tan{\delta}$ and $\Deta$I of No. 1 and No. 2 model stator bars increased with increased in aging time.

  • PDF