• 제목/요약/키워드: Degrees of Freedom Motion

검색결과 342건 처리시간 0.024초

초정밀 위치결정을 위한 6자유도미동기구의 궤적 특성에 관한 연구 (A Study on Trajectory Characteristics of the Six-Degrees-of-Freedom Fine Motion Mechanism for the Ultra Precision Positioning Decision)

  • 김재열;윤성운
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose of this research is to examine precise linear motion and rotary motion. A six-degrees-of-freedom fine motion mechanism is introduced to drive an object precisely in directions of X, Y and Z-axes and around them : three rectangular linear motion and rotary ones. An experimental mechanism is introduced in which a $70$\times$70$\times$70$\times$(${mm}^3$) cube object is driven by six PZT actuator. The study is to establish the six-degrees-of-freedom fine motion mechanism of linear motion and rotary motion using PZT actuator.

  • PDF

2자유도 동작범위를 고려한 reach volume의 해석적 생성 (Analytic Generation of Reach Volume Based on Range of Two Degrees of Freedom Motion)

  • 기도형
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.147-162
    • /
    • 1997
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chinese populations. Furthermore, reach volume considering foot or trunk motion have not been investigated. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. However, range of two degrees of freedom motion has not been measured up to now. Therefore, range of two degrees of freedom motion was measured in this research, where 47 college students were participated voluntarily as subjects. The results showed that the motion of one joint can be limited by the motion of another motion, that is to say, the shoulder flexion was decreased significantly when the shoulder was adducted or abducted. Second, new approximate algorithms generating reach volumes were suggested, in which range of two degrees of freedom motion was used as input data. Depending upon the body segment included such as trunk, arm and leg, three types of reach volume were provided, in which the human body was modeled as a multilink system based on the robot kinematics and the sweeping method was employed. Reach volume generated analytically in this study showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

작업영역의 해석적 생성을 위한 2자유도 동작의 동작범위 측정 (Measurement on range of two degrees of freedom motion for analytic generation of workspace)

  • 기도형
    • 대한인간공학회지
    • /
    • 제15권2호
    • /
    • pp.15-24
    • /
    • 1996
  • To generate workspace analytically using the robot kinematics, data on range of human joints motion, especially range of two degrees of freedom motion, are needed. However, these data have not been investigated up to now. Therefore, in this research, we are to investigate an interaction effect of motions with two degrees of freedom occurred simultaneously at the shoulder, virtual hip(L5/S1) and hip joints, respectively, for 47 young male students. When motion with two degrees of freedom occurred at a joint such as shoulder, virtual hip and hip joints, it was found from the results of ANOVA that the action of a degree of freedom motion may either decrease or increase the effective functioning of the other degree of freedom motion. In other words, the shoulder flexion was decreased as the shoulder was adducted or abducted to $60^{\circ}C$TEX>or abducted from $60^{\circ}C$TEX>to maximum degree of abduction, while the shoulder flexion increased as the joint was abducted from $60^{\circ}C$TEX> to $60^{\circ}C$TEX> The flexion was decreased as the virtual hip was bent laterally at the virtual hip joint, and also did as the hip was adducted or abducted from the neutral position. It is expected that workspace can be generated more precisely based the data on the range of two degrees of joint motion measured in this study.

  • PDF

2자유도를 갖는 3차원 운동 시뮬레이터 연구 (Implementation of 3D Motion Simulator with Two Degrees of Freedom)

  • 최명환;김영진
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.81-88
    • /
    • 2001
  • In this work, we have developed a 2 degrees of freedom(DOF) motion simulator that can generate the sensation of motion in a 6 DOF space. The motion base has the DOF of roll and pitch, and the purpose of the motion base is to create the sensation of riding a vehicle in a 3D space by controlling the motion base. The dynamics of the mechanism was analysed and the optimal design of the motion base mechanism has been reached. The prototype motion base mechanism was developed and tested. The multi-axis motion controller(MMC) was used to control the two AC servo meters that drive the roll and pitch motion.

  • PDF

The design of six degrees of freedom stewart motion platform using high power electro-hydraulic servo control

  • Kim, Young-Dae;Lee, Kwan-Sup;Kim, Chung-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1611-1616
    • /
    • 1991
  • A high power stewart platform is designed and manufactured to simulate the 6 degrees of freedom motion of moving vehicle. This paper describes the design of such a motion system including kinematic and kinetic analysis, real time servo control mechanical and hydraulic system configuration, and techniques of regeneration of test records. Discussions are also presented for an algorithm called remote parameter control, which has been developed to compensate the dynamic delay of the electro-hydraulic servo actuators and the nonlinearities of stewart platform.

  • PDF

인간공학기반 7자유도 모션캡쳐 장치 설계 (Ergonomics-based Design of 7 Degrees of Freedom Motion Capture Device)

  • 노병국;최기흥
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.41-46
    • /
    • 2014
  • The design of a 7 degree of freedom motion capture device(MCD) has been presented. The newly designed MCD overcomes the shortcomings of the existing CADEN-7 exoskeleton robot by implementing various ergonomic design. To improve ease of operation, light-weight high-strength materials such as carbon pipes and engineering plastics were used to reduce weight of the MCD and arm-length adjustment mechanism was also added. The MCD showed consistent measurement results in designed experiments involving change of arm posture from nominal configuration to either elbow-side or arm-front configurations. Furthermore, captured motion in more natural tennis swing appeared to agree well with visual observations made.

Reach volume의 측정과 로보트 기구학을 이용한 해석적 생성의 비교

  • 기도형;신용탁;강동석;정의승
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1996년도 추계학술대회논문집
    • /
    • pp.232-237
    • /
    • 1996
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chineses populations, and foot reach and trunk motion have been excluded. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. Therefore, in this research, range of two degrees of reedom motion was measured, in which 47 college students were participated volumtarily as subjects. Second, new approximate algorithms generating reach volumes were suggested based on the robot kinematics, in which range of two degrees of freedom motion was considered. Our analytically generated reach volume showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

SCARA robot를 위한 4자유도 end-effector 개발 (Four degrees of freedom robot gripper for assembly robots)

  • 오세훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.511-516
    • /
    • 1991
  • A new end-effector has been devised and the problems resulted from using it with SCARA robots are discussed. The end effector has two modules: one composed of two ultrasonic motors and two encoders for controlling each finger, and the other module composed of two ultrasonic motors and two encoders for controlling the wrist. The wrist module adds two degrees of freedom to the SCARA type robot, which generally has four degrees of freedom. With independent finger actuation and touch sensors, the gripper under computer control can feedback information about part size and part presence. Ultrasonic motors with high torque and slow motion characteristics are used. The principle of ultrasonic motors is explained and the servo characteristics of ultrasonic motors are studied. They are controlled by the general motion controller (Hewlett Packard HCTL-1000) which is linked to an IBM-PC AT.

  • PDF

머시닝센터 장착형 2축 연마 로봇의 성능평가 (The Evaluation of Performance of 2-Axis Polishing Robot Attached to Machining Center)

  • 박준혁
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.411-416
    • /
    • 2000
  • Cutting process has been automated by progress of CNC and CAD/CAM, but polishing process has been depended on only experiential knowledge of expert. To automate the polishing process, a polishing robot with w degrees of freedom which is attached to a machining center with 3 degrees of freedom has been developed. This automatic polishing robot is able to keep the polishing tool normal on the curved surface of die to improve a performance of polishing. Polishing task for a curved surface die demands repetitive operation and high precision, but conventional control algorithm can not cope with the problem of disturbance such as a change of load. In this research, a new sliding mode control algorithm is applied to the robot. The signal compression method is used to identify polishing robot system. to obtain an effect of 5 degrees of freedom motion, a synchronization between the machining center and polishing robot is accomplished by using M code of machining center. And also a trajectory for polishing the curved surface die by 5 degrees of freedom motion, a synchronization between the machining center and polishing robot is accomplished by using M code of machining center. And also a trajectory for polishing the curved surface die by 5 axes machining center is divided into data of two types for 3 axes machining center and 2 axes polishing robot. To evaluate polishing performance of the robot. various experiments are carried out.

  • PDF

병진운동 강체의 온라인 5자유도 운동오차 측정시스템 설계 및 해석 (Synthesis of an On-Line 5 Degrees of Freedom Error Measurement System for Translational Motion Rigid Bodies)

  • 김진상;정성종
    • 한국정밀공학회지
    • /
    • 제15권5호
    • /
    • pp.93-99
    • /
    • 1998
  • Although laser interferometer measurement system has advantages of measurement range and accuracy, it has some disadvantages when measurement of multi degrees of freedom of motion are required. Because the traditional error measurement methods for geometric errors (two straightness and three angular errors) of a slide of machine tools measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric errors of a moving rigid body in real time processes, an on-line error measurement system for simultaneous detection of the five error components of a moving object is required. Using laser alignment technique and some optoelectronic components, an on-line measurement system with 5 degrees of freedom was developed for the geometric error detection in this study Performance verification of the system has been performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a slide of machine tools.

  • PDF