• 제목/요약/키워드: Degree reduction

검색결과 1,444건 처리시간 0.032초

Strongly coupled partitioned six degree-of-freedom rigid body motion solver with Aitken's dynamic under-relaxation

  • Chow, Jeng Hei;Ng, E.Y.K.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.320-329
    • /
    • 2016
  • An implicit method of solving the six degree-of-freedom rigid body motion equations based on the second order Adams-Bashforth-Moulten method was utilised as an improvement over the leapfrog scheme by making modifications to the rigid body motion solver libraries directly. The implementation will depend on predictor-corrector steps still residing within the hybrid Pressure Implicit with Splitting of Operators - Semi-Implicit Method for Pressure Linked Equations (PIMPLE) outer corrector loops to ensure strong coupling between fluid and motion. Aitken's under-relaxation is also introduced in this study to optimise the convergence rate and stability of the coupled solver. The resulting coupled solver ran on a free floating object tutorial test case when converged matches the original solver. It further allows a varying 70%-80% reduction in simulation times compared using a fixed under-relaxation to achieve the required stability.

WDM 광통신 시스템을 위한 단일모드 광섬유 무편광기 (Single-mode fiber depolarizer for WDM optical communications)

  • 이동렬;전상민;김용평
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.224-229
    • /
    • 2003
  • 2$\times$2 방향성 결합기와 단일모드 광섬유를 이용하여 무편광기를 구현하였다. 행렬식을 이용한 모의실험을 통해 편광도를 줄이는 방법을 이론적으로 설명하였고 이를 실험적으로 검증하였다. 0.05 nm 이하의 좁은 선폭을 가진 편광된 입력광원의 편광상태 변화에 대해 -20 dB의 출력 편광도를 얻을 수 있었다 광섬유 지연선의 길이를 광원의 가간섭 길이보다 충분히 길게 함으로써 입력광의 편광 변화에 의한 강도 잡음을 효과적으로 없앨 수 있음을 실험적으로 검증하였다.

모형연소기에서 연료-공기의 혼합정도 및 당량비가 NOx 배출과 열 방출량에 미치는 영향에 대한 연구 (Effect of the Degree of Fuel-Air Mixing and Equivalence Ratio on the NOx Emission and Heat Release in a Dump Combustor)

  • 조봉국;최도욱;김규보;장영준;송주헌;전충환
    • 대한기계학회논문집B
    • /
    • 제33권9호
    • /
    • pp.658-665
    • /
    • 2009
  • Lean premixed combustors are used for significant NOx reduction which one of issues in current gas turbine combustor. This study was investigated to estimate the effects of the unmixedness of fuel-air, equivalence ratio on the instability mechanism, NOx emission and combustion oscillation in a lean premixed combustor. The experiments were conducted in a dump combustor at atmospheric pressure conditions using methane as fuel. The swirler angle was $45^{\circ}$, the degrees of fuel-air mixing were 0, 50 and 100 and inlet temperature was 650K. The equivalence ratio was ranging from 0.5 to 0.8. This paper shows that NOx emission was increased when the degree of fuel-air mixing is increased in same equivalence ratio and when equivalence ratio is increased. And the range of the combustion instability was enlarged as a function of increasing of the degree of fuel-air mixing.

Power Assisted Liposuction(PAL)과 병용한 외부 초음파의 효과에 대한 비교 연구 (A Comparative Study of the Effect of External Ultrasound with Power Assisted Liposuction(PAL))

  • 송인수;박준;유영천;양원용;김진영
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.496-502
    • /
    • 2005
  • This study was performed to compare the effect of external ultrasound assisted PAL(power assisted liposuction) with that of PAL alone. We performed 17 cases of liposuction from January 2003 to June 2003. For comparing both systems, we treated the right side(study group) with external ultrasound assisted PAL and the left side(control group) with PAL alone. To evaluate the difference in results between two groups, we surveyed three objective and four subjective items. Objectives were categorized as "Reduction rate of postoperative swelling", "Efficiency of suction" and "Histologic finding of aspirated fat tissue". Subjectives were also filed as "Degree of postoperative bruising", "Cannula resistance that operator felt", "Degree of postoperative pain" and "Patient's satisfaction". We assessed by questionnaire three times at 1day, 7 days and 30 days after operation. There were statistically significant differences in two of the subjective items; "Degree of postoperative pain at postoperative 1 day" and "Cannula resistance that operator felt". This study concludes that external ultrasound PAL is more effective high mobility of fat tissue and low tension of surrounding tissue. External ultrasound PAL will be more useful in case of large volume liposuction and revision procedures.

Effect of presoaking degree of lightweight aggregate on the properties of lightweight aggregate concrete

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.69-78
    • /
    • 2017
  • This study aimed at exploring the effect of presoaking degree of lightweight aggregate (LWA) on the fresh and hardened properties of concrete. Two series (i.e., Series A and Series B) of concrete mixes that were made of LWA with different moisture states were prepared. The presoaking degree of LWA was divided into three types: oven dry state, 1 hour prewetted and 24 hours prewetted. For the Series A, the water content of the lightweight aggregate concrete (LWAC) mixes was adjusted in accordance with the moisture condition of the LWA. Whereas the amount of water added in the Series B mixes was deliberately not adjusted for the moisture condition of the LWA. Slump test, mechanical tests, interfacial transition zone microscopical tests and thermal conductivity test were carried out on the specimens of different concretes and compared with control normal-weight aggregate concretes. The test results showed that the effect of mixing water absorption by LWA with different moisture states was reflected in the fresh concrete as the loss of mixture workability, while in the hardened concrete as the increase of its strength. With the use of oven-dried LWA, the effect of reduction of water-cement ratio was more significant, and thus the microstructure of the ITZ was more compact.

저온잠열축열을 위한 TMA-물계 포접화합물의 냉각특성 (TMA-Water Clathrate Compound of Cooling Characteristics for Low Temperature Latent Heat Storage)

  • 김창오;정현호;정낙규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.296-301
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.

  • PDF

고추씨 기름의 저장 및 가열에 따른 이화학적 변화에 관한 연구 (Studies on the Variation of Physico-Chemical Characteristics During Storage and Frying)

  • 최영진;고영수
    • 한국식품조리과학회지
    • /
    • 제6권2호
    • /
    • pp.67-76
    • /
    • 1990
  • To observe the propability as the frying oil and oxidative stability of red pepper seed oil, some physico-chemical tests of the oil were examined during 21 days storage period at 5$^{\circ}C$, 15$^{\circ}C$ and 30$^{\circ}C$, and AOM value determined and after heating the oil at 180${\pm}$5$^{\circ}C$ for 40 hours with or without antioxidants. The analysis storage stability of red pepper seed oil showed that the quality of storage group at 5$^{\circ}C$ was almost as good as fresh oil, and the storage group at 30$^{\circ}C$ showed certain degree of rancidity. Change of physico-chemical characteristic during storage were so small so that storage stability of red pepper seed oil was found to be good. AOM stability of red pepper seed oil was 7 hours which is lower than other vegetable oil, but the degree of stability grew greatly after adding phenolic antioxidants, such on TBHQ or PG. As for the chemical change after heating continuously for 40 hours, acid value, peroxide value and refractive index increased, but iodine value decreased as the heating processed. The fatty acid composition also showed the remarkable reduction of linoleic acid. The addition of antioxidants resulted in the delay of oxidation, the degree of which was greater in TBHQ than in PG.

  • PDF

정상 성인의 슬괵근 유연성 정도에 따른 체간 굴곡시 요추의 운동학적 분석 (Kinetic Analysis on the Lumbar at the Trunk Flexion according to the Degree of Hamstring Flexibility of Healthy Adult)

  • 김기철;황보각
    • 대한물리의학회지
    • /
    • 제7권4호
    • /
    • pp.501-507
    • /
    • 2012
  • PURPOSE: This study aims to examine the effects of trunk flexion on the kinetic characteristics of the lumbar according to the degree of hamstring flexibility. METHODS: This study has as its subjects 29 young adults and divides them into the group (NSRTG, n=15) with the normal length of hamstrings according to SRT and the group (SSRTG, n=14) tending to have shortened hamstrings. Sit and Reach Test was conducted to evaluate the degree of hamstring flexibility. And to examine the kinetic difference of the lumbar at the trunk flexion, it was compared and analyzed by using the picture archiving and communication system (PACS). RESULTS: SSRTG showed more significant difference than NSRTG in the analysis on the trunk flexion of NSRTG and SSRTG. CONCLUSION: According to the analysis, the shortening of hamstrings is the factor that affects the dynamic stability of the lower lumbar through the reduction of the pelvic anterior tilt at the trunk flexion.

Relation between total degradation of steel concrete bond and degree of corrosion of RC beams experimental and computational studies

  • Maurel, Olivier;Dekoster, Mickael;Buyle-Bodin, Francois
    • Computers and Concrete
    • /
    • 제2권1호
    • /
    • pp.1-18
    • /
    • 2005
  • This paper presents a study on the effects of localized steel-concrete bond degradation on the flexural behaviour of RC beams. A finite element analysis is undertaken to complete the experimental analysis. The first part deals with an experimental study on beams where bond was removed by using plastic tube at different locations and for various lengths. The flexural behaviour was studied at global scale (load-deflection) and local scale (moment-curvature). The second part, a numerical study using a simplified special finite element (rust element) modelling the rust layer occurring between reinforcement and concrete with corrosion was conducted in order to find the relation between the degree of corrosion and the degradation of the steel-concrete bond. The computed value of the corrosion degree corresponding to the total degradation of bond has been used in a second time to model the tests, in order to evaluate the influence of the loss of bond, the steel cross section reduction, and the combination of both. The results enable to evaluate the influence of the different corrosion effects on the flexural behaviour, according to the length and the location of the corroded zone.

The Cooling Characteristics of Clathrate Compound according to Concentration of TMA

  • Lee, Jong-In;Kim, Chang-Oh;Chung, Nak-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.32-36
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N$) of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25 wt% has the average phase change tempera ture of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.