• 제목/요약/키워드: Deformed steel bar

검색결과 54건 처리시간 0.057초

New emerging surface treatment of GFRP Hybrid bar for stronger durability of concrete structures

  • Park, Cheolwoo;Park, Younghwan;Kim, Seungwon;Ju, Minkwan
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.593-610
    • /
    • 2016
  • In this study, an innovative and smart glass fiber-reinforced polymer (GFRP) hybrid bar was developed for stronger durability of concrete structures. As comparing with the conventional GFRP bar, the smart GFRP Hybrid bar can promise to enhance the modulus of elasticity so that it makes the cracking reduced than the case when the conventional GFRP bar is used. Besides, the GFRP Hybrid bar can effectively resist the corrosion of conventional steel bar by the GFRP outer surface on the steel bar. In order to verify the bond performance of the GFRP hybrid bar for structural reinforcement, uniaxial pull-out test was conducted. The variables were the bar diameter and the number of strands and pitch of the fiber ribs. Tensile tests showed a excellent increase in the modulus of elasticity, 152.1 GPa, as compared to that of the pure GFRP bar (50 GPa). The stress-strain curve was bi-linear, so that the ductile performance could be obtained. For the bond test, the entire GFRP hybrid bar test specimens failed in concrete splitting due to higher shear strength resulting in concrete crushing as a function of bar deformation. Investigation revealed that an increase in the number of strands of fiber ribs enhanced the bond strength, and the pitch guaranteed the bond strength of 19.1 mm diameter hybrid bar with 15.9 mm diameter of core section of deformed steel the ACI 440 1R-15 equation is regarded as more suitable for predicting the bond strength of GFRP hybrid bars, whereas the CSA S806-12 prediction is considered too conservative and is largely influenced by the bar diameter. For further study, various geometrical and material properties such as concrete cover, cross-sectional ratio, and surface treatment should be considered.

도넛형 이방향 중공슬래브의 부착특성에 관한 실험적 연구 (An Experimental Study for Bond Characteristics of Deformed Bar Embedded in Donut Type Biaxial Hollow Slab)

  • 정주홍;강성훈;이승창;최창식;최현기
    • 콘크리트학회논문집
    • /
    • 제25권2호
    • /
    • pp.155-163
    • /
    • 2013
  • 이 연구는 도넛형 이방향 중공슬래브에 매입된 이형철근의 부착특성 및 부착강도 산정을 위한 기초적인 연구이다. 도넛형 이방향 중공슬래브의 철근 부착특성 및 부착강도 산정을 위해 pull-out test를 수행하였다. 도넛형 중공형성체는 슬래브 내부에 배치되어 철근과 중공형성체 사이에 내부의 피복이 형성된다. 이러한 내부피복두께는 외부피복두께보다 상대적으로 작은 피복두께를 가지며 중공형상에 따라 $2.5d_b$보다 작은 내부피복두께가 형성되기 때문에 철근의 부착에 영향을 미치게 된다. 또한 중공형성체가 일정 간격으로 떨어져 배치되어 있으므로 인장철근을 감싸고 있는 피복두께의 조건이 철근의 길이방향으로 변하게 된다. 따라서 도넛형 이방향 중공슬래브의 부착특성을 알아보기 위해서 중공형성체 형상에 따라 부착구간을 구분하였다. 구간별로 내부피복두께에 따른 부착응력-슬립 관계를 확인하였으며, 중공형성체 전 구간에 걸친 부착응력분포를 확인하여 철근의 길이방향에 따른 부착응력의 발현정도를 확인하였다. 또한 구간별 부착응력-슬립 관계를 기반으로 하여 도넛형 중공슬래브의 부착강도를 산정할 수 있는 부착강도 산정 방법을 제안하였다.

외피형태에 따른 GFRP 보강근의 겹침 이음길이 (Lap Splice Length of Glass Fiber Reinforced Polymer (GFRP) Reinforcing Bars with Different Surface Design)

  • 최동욱;이창호;하상수;박영환;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.449-452
    • /
    • 2004
  • The lap splice lengths of deformed steel reinforcing bars and GFRP bars with two different to surface type were experimentally compared using beam specimens. The purpose was to evaluate the length required of the GFRP bar to develop strength equivalent to the conventional steel reinforcing bar. The main test variable was the lap splice length. Two different GFRP bar surfaces were tested: (1) spiral-type GFRP bars and (2) sand coated GFRP bars. For the conventional steel bars (SD400 grade), strength over 400 MPa in tension was reached using the lap splice length of $30d_b$. Splice failure was observed in the specimen with the lap splice length of $20d_b$. For the spiral-type and sand coated GFRP bars, the tensile strength developed in the GFRP bars decreased with decreasing splice lengths. Development of the cracks on beam surfaces was clearly visible for the beams reinforced with the GFRP bars. Mid-span deflections, however, were significantly smaller than the comparable beams with conventional steel bars indicating potential ductility problem.

  • PDF

경량콘크리트와 GFRP 보강근의 부착 특성 (Bond Characteristic Between Lightweight Concrete and GFRP Bar)

  • 손병락;김명식;김충호;장희석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.112-121
    • /
    • 2013
  • FRP 보강근을 사용한 경량콘크리트 구조체는 부식방지 및 자중감소의 효과를 동시에 기할 수 있는 이점이 있어서 추후 그 활용이 기대될 수 있다. 그러나 경량콘크리트와 FRP 보강근을 사용하여 보강근의 내부슬립 없이 외력에 저항할 수 있는 구조체를 만들기 위해서는 경량콘크리트와 FRP 보강근 사이의 부착특성을 파악하는 것이 대단히 중요하다. 그동안 보통콘크리트와 FRP 보강근 사이의 부착거동에 대하여는 많은 연구가 있어 왔으나 경량콘크리트와 FRP 보강근 사이의 부착거동에 대하여는 현재까지 연구결과가 대단히 부족한 실정이다. 따라서 본 연구에서는 경량콘크리트와 보강근 표면에 나선형태의 이형을 갖는 GFRP 보강근 사이의 부착특성을 조사하였다. 비교목적으로 보강근 종류, 콘크리트 종류, 경량콘크리트 강도종류의 실험변수를 고려하여 인발실험체들을 제작하고 실험을 행하였다. 실험분석 결과, 보통콘크리트와 철근을 사용한 실험체의 부착강도를 1.0으로 하였을 때 경량콘크리트와 나선형태의 이형을 갖는 GFRP 보강근을 사용한 실험체의 부착강도는 0.49로 나타났다.

Local bond stress-slip behavior of reinforcing bars embedded in lightweight aggregate concrete

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.449-466
    • /
    • 2015
  • This paper aims to study the local bond stress-slip behavior of reinforcing bars embedded in lightweight aggregate concrete (LWAC). The experimental variables of the local bond stress-slip tests include concrete strength (20, 40 and 60 MPa), deformed steel bar size (#4, #6 and #8) and coarse aggregate (normal weight aggregate, reservoir sludge lightweight aggregate and waterworks sludge lightweight aggregate). The test results show that the ultimate bond strength increased with the increase of concrete compressive strength. Moreover, the larger the rib height to the diameter ratio ($h/d_b$) of the deformed steel bars is, the greater the ultimate bond stress is. In addition, the suggestion value of the CEB-FIP Model Code to the LWAC specimen's ultimate bond stress is more conservative than that of the normal weight concrete.

Effect of high temperatures on local bond-slip behavior between rebars and UHPC

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.163-178
    • /
    • 2022
  • This paper aimed to study the local bond-slip behavior between ultra-high-performance concrete (UHPC) and a reinforcing bar after exposure to high temperatures. A series of pull-out tests were carried out on cubic specimens of size 150×150×150 mm with deformed steel bar embedded for a fixed length of three times the diameter of the tested deformed bar. The experimental results of the bond stress-slip relationship were compared with the Euro-International Concrete Committee (CEB-Comite Euro-International du Beton)-International Federation for Prestressing (FIP-Federation Internationale de la Precontrainte) Model Code and with prediction models found in the literature. In addition, based on the test results, an empirical model of the bond stress-slip relationship was proposed. The evaluation and comparison results showed that the modified CEB-FIP Model code 2010 proposed by Aslani and Samali for the local bond stress-slip relationship for UHPC after exposure to high temperatures was more conservative. In contrast, for both room temperature and after exposure to high temperatures, the modified CEB-FIP Model Code 2010 local bond stress-slip model for UHPC proposed in this study was able to predict the test results with reasonable accuracy.

철근격자망을 사용한 슬래브-벽체 접합부의 구조성능 (Structural Performance of RC Slab-Wall Joints Reinforced by Welded Deformed Steel Bar Mats)

  • 박성식;윤영호;이범식
    • 토지주택연구
    • /
    • 제2권1호
    • /
    • pp.61-68
    • /
    • 2011
  • 본 연구는 벽식구조 아파트의 슬래브와 벽체를 철근격자망으로 배근할 경우 접합부의 구조성능을 검증하기 위해 수행되었다. 이를 위해 벽체와 연결된 불연속단의 캔틸레버형 슬래브 시험체를 사용하여 철근격자망 상부근의 정착길이와, 철근격자망의 정착부에 일반 구부림 철근을 사용하여 정착한 경우의 정착방법 및 길이를 변수로 실험을 수행하였다. 결과는 다음과 같다. (1) 슬래브-벽체 외부접합부의 철근망 시공에서 슬래브 철근망은 벽체의 철근 선까지 배근하고 이음길이를 확보한 별도의 철근을 $90^{\circ}$ 표준갈고리로 정착하는 경우, 정착길이와 단면적이 확보되면 강도 발현에 문제가 없는 것으로 나타났다. (2) 슬래브 철근망을 접합부에서 이음할 때 철근망의 철근을 벽체 속으로 매입하면 강도는 더욱 증가한다. 그러나 최고강도에 도달한 이후의 연성은 이음이 없는 것과 동일한 것으로 나타났다. (3) 슬래브-벽체 외부접합부에서 단부 모멘트에 대한 슬래브 하부 압축콘크리트의 파괴시 변형률은 일반 콘크리트 보와 비교할 때 훨씬 큰 것으로 나타났다. 이는 슬래브-벽체 접합부가 $90^{\circ}$를 이루고 있어 이에 따른 구속효과가 있기 때문인 것으로 판단된다.

강 용접 열영향부 놋치 선단 의 소성 스트레인 평가에 관한 연구 (A Study on Evaluation of Plastic Strain at Notch Tip of Weld HAZ in Steel)

  • 김태영;임재규;정세희
    • Journal of Welding and Joining
    • /
    • 제2권1호
    • /
    • pp.41-48
    • /
    • 1984
  • Recrystallization technique was applied to analyze plastic strain at the notch tip of coarse grain HAZ in mild steel (SB 41) and high strength steel (SA 588). The notch tip of specimen was deformed by three point bending. Accumulated displacement (Crack Opening Displacement ${delta}t$) by the monotonic and cyclic loading under room temperature and hot strain embrittlement temperature ($250^{\circ}C$) was 0~1.0mm. Recrystallization heat treatment conditions were $650^{circ}C{ imes}3hr$ for SB 41 and $700^{circ}C{ imes}3hr$ for SA 588. The experimental results obtained were as follows ; 1) Distribution of the effective plastic strain at plastic zone was appeared by the function of crack opening displacement, and plastic zone or the effective plastic strain increased with crack opening displacement. 2) Plastic strain at notch tip of HAZ due to accumulated hot strain calculated as follows. .epsilon. over bar $_{p}$ = .epsilon. over bar $_{cr}$ (x/ $R_{x}$ ) $^{m}$ (m=0.25) 3) Work hardending ratio of notch tip for hot strain was linearly increased with .epsilon. over bar $_{max}$ and dependent upon the material types.s.

  • PDF

Experimental evaluation of external beam-column joints reinforced by deformed and plain bar

  • Adibi, Mahdi;Shafaei, Jalil;Aliakbari, Fatemeh
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.113-127
    • /
    • 2020
  • In this study, the behavior of external beam-column joints reinforced by plain and deformed bars with non-seismic reinforcement details is investigated and compared. The beam-column joints represented in this study include a benchmark specimen by seismic details in accordance with ACI 318M-11 requirements and four other deficient specimens. The main defects of the non-seismic beam-column joints included use of plain bar, absence of transverse steel hoops, and the anchorage condition of longitudinal reinforcements. The experimental results indicate that using of plain bars in non-seismic beam-column joints has significantly affected the failure modes. The main failure mode of the non-seismic beam-column joints reinforced by deformed bars was the accumulation of shear cracks in the joint region, while the failure mode of the non-seismic beam-column joints reinforced by plain bars was deep cracks at the joint face and intersection of beam and column and there was only miner diagonal shear cracking at the joint region. In the other way, use of plain bars for reinforcing concrete can cause the behavior of the substructure to be controlled by slip of the beam longitudinal bars. The experimental results show that the ductility of non-seismic beam-column joints reinforced by plain bars has not decreased compared to the beam-column joints reinforced by deformed bars due to lack of mechanical interlock between plain bars and concrete. Also it can be seen a little increase in ductility of substructure due to existence of hooks at the end of the development length of the bars.