• Title/Summary/Keyword: Deflector baffle

Search Result 2, Processing Time 0.021 seconds

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

Evaluation of Hydraulic Characteristics Influenced by Different Deflector Baffles in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지에서 저류벽의 설치위치에 따른 수리학적 특성의 평가)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Ryu, Seong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Sedimentation is one of the most common and important units in conventional water treatment plant. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the two sedimentations at Y water treatment plant (YWTP), which have different deflector baffles inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused an undesirable impact on horizontal flow and produced dead zone. Solid baffle wall under the plate settler could help to minimize the formation of density currents and flow short circuiting. NaF used as a tracer was recovered more than 90% at investigated all basins. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p]/M-HRT$) were determined from tracer test results performed at YWTP. Those indices ranged 2.95~3.02, 0.40~0.53 and 0.32~0.46, respectively.