• 제목/요약/키워드: Defects of Houses

검색결과 42건 처리시간 0.017초

Study on the performance indices of low-strength brick walls reinforced with cement mortar layer and steel-meshed cement mortar layer

  • Lele Wu;Caoming Tang;Rui Luo;Shimin Huang;Shaoge Cheng;Tao Yang
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.439-453
    • /
    • 2023
  • Older brick masonry structures generally suffer from low strength defects. Using a cement mortar layer (CML) or steel-meshed cement mortar layer (S-CML) to reinforce existing low-strength brick masonry structures (LBMs) is still an effective means of increasing seismic performance. However, performance indices such as lateral displacement ratios and skeleton curves for LBMs reinforced with CML or S-CML need to be clarified in performance-based seismic design and evaluation. Therefore, research into the failure mechanisms and seismic performance of LBMs reinforced with CML or S-CML is imperative. In this study, thirty low-strength brick walls (LBWs) with different cross-sectional areas, bonding mortar types, vertical loads, and CML/S-CML thicknesses were constructed. The failure modes, load-carrying capacities, energy dissipation capacity and lateral drift ratio limits in different limits states were acquired via quasi-static tests. The results show that 1) the primary failure modes of UBWs and RBWs are "diagonal shear failure" and "sliding failure through joints." 2) The acceptable drift ratios of Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) for UBWs can be 0.04%, 0.08%, and 0.3%, respectively. For 20-RBWs, the acceptable drift ratios of IO, LS, and CP for 20-RBWs can be 0.037%, 0.09%, and 0.41%, respectively. Moreover, the acceptable drift ratios of IO, LS, and CP for 40-RBWs can be 0.048%, 0.09%, and 0.53%, respectively. 3) Reinforcing low-strength brick walls with CML/S-CML can improve brick walls' bearing capacity, deformation, and energy dissipation capacity. Using CML/S-CML reinforcement to improve the seismic performance of old masonry houses is a feasible and practical choice.

경찰화재조사의 개선방안에 관한 연구 (A Study on the Improvement Plans of Police Fire Investigation)

  • 서문수철
    • 한국화재조사학회지
    • /
    • 제9권1호
    • /
    • pp.103-121
    • /
    • 2006
  • 우리나라에서 발생한 화재 원인조사 대부분은 소방관서에서 초기조사, 경찰관서에서 수사가 진행되고 있으며, 보다 난해하거나 이해관계가 복잡한 경우인 일부만이 경찰에서 심도 있게 조사하고 경찰조사 시 감정이 필요한 경우 감정기관에 감정의뢰 후 경찰관서 자체조사만으로 끝나며, 점차 전문기관에 의뢰되고 있는 건수가 증가하고 있는 실정이나 많은 문제점을 안고 있어 이에 대안을 제시한다. 국내 화재사고 발생 건수는 소방방재청 통계 연간 약 30만 건으로 추산되나, 전국 경찰화재감식 전문 요원(국립과학수사연구소 전문화 교육 이수자)은 80여명에 지나지 않으며, 국립과학수사연구소 화재감정 관련 연구원은 전국에 15명인 것에 비추어 사건화 된 화재에 대한 감식 감정 인력은 턱없이 모자라 과중한 업무를 수행하고 있는 실정이다. 가연성 액체에 의한 방 실화 시 바닥재의 연소형태를 비교 연구함으로써 연소에 사용된 연소촉매제에 대하여 추론 할 수 있는 연구를 실시하여 모델을 제시하였다. 화재사건 관련 감식 감정 업무를 담당하고 있는 경찰 및 국립과학수사연구소의 과중한 업무의 부담인 의뢰 건수의 폭주로, 경찰 화재 감식의 대상 중 범죄혐의(방화, 실화 등)가 있는 사건은 전체 조사 건수의 20% 미만이고, 나머지 80%에 달하는 사건이 범죄혐의 없는 제조물 관련 또는 이재 관계의 민사 소송 사건에 지나지 않는 것이 현실이다. 본 연구는 경찰화재조사 및 소방화재조사에 대한 검토와 문제점 대안 등을 제시하여 화재사건과 관련하여 경찰 소방 양 기관에서 합동으로 사건을 처리하는 것이 과오를 범하지 않는 효율적이고 과학적인 수사가 될 수 있다는 제도개선이 필요함이 요구된다.

  • PDF