• 제목/요약/키워드: Defected Region

검색결과 23건 처리시간 0.029초

결함을 가지는 모델을 이용한 허브 홀 확장에서의 파단 예측 (Prediction of fracture in hub-hole expansion with a defected-edge model)

  • 이종섭;허훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.131-134
    • /
    • 2004
  • The hub hole is usually formed with a stretch flanging process followed by a blanking process of a hole. Since the hole is made by blanking, the blanked surface is so rough that the formability in the region is rather poor. The emerging task is to identify the formability of the blanked region in the forming simulation and to relate the criterion to the real forming process by experiments. In this paper, the blanked region of a hole surface is modeled by a defected-edge finite element for stretch flanging simulation. The analysis deals with the level of defect in the blanked region in order to identify the formability in the real process. The analysis provides the formability depending on the level of defect and seeks the way to match the level of defect to that of the real surface. The approach makes the analysis possible to deal with the formability of the high strength steel and predict the fracture at the hole surface during the stretch flanging simulation.

  • PDF

DBSCAN 기반의 제조 공정 데이터 불량 위치의 검출 (Detection of the Defected Regions in Manufacturing Process Data using DBSCAN)

  • 최은석;김정훈;아지즈 나스리디노프;이상현;강정태;류관희
    • 한국콘텐츠학회논문지
    • /
    • 제17권7호
    • /
    • pp.182-192
    • /
    • 2017
  • 제조 산업은 국가 경제 성장의 원동력으로 그 중요성이 부각되고 있다. 이에 따라 제조 공정상에서 생성되는 제조 데이터 분석의 중요성 또한 조명 받고 있다. 본 논문에서는 PCB(Printed Circuit Board) 제조 공정에서 발생한 로그 데이터를 분석하여 PCB 상에서 빈번하게 발생하는 고장 영역에 대해서 작업자가 고장 영역을 직접 눈으로 볼 수 있도록 시각화하는 방법을 제안한다. 우선 고장 영역을 파악하기 위해서 PCB 공정 데이터 집합에 K-means, DB-SCAN 클러스터링 알고리즘을 적용하여 군집화 하였고, 두 알고리즘 중 더 정확한 고장 영역을 도출하는지 비교하였다. 또한 MVC(Model-View-Controller) 구조 시스템을 개발하여 실제 PCB 이미지 상에 클러스터링 결과를 출력하는 것으로 실제 고장영역을 눈으로 확인할 수 있도록 시각화하였다.

악골 내 발생한 낭종의 적출술 후 자발적인 골의 재생에 대한 파노라마 방사선 분석 (PANORAMIC ANALYSIS ABOUT SPONTANEOUS BONE REGENERATION AFTER ENUCLEATION OF JAW CYST)

  • 임정훈;이재훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권3호
    • /
    • pp.229-236
    • /
    • 2009
  • Purpose: Some recent literatures report that it is possible to recover defected areas caused by enucleation of relatively large jaw cysts without using bone grafts. The aim was to find out whether spontaneous recovery of defected area with time occurred and what the contributing factors were. Materials and methods: In total, 194 patients were considered as patients. Out of these 194 patients, 74 patients who had no wound dehiscence and who were available for follow-up studies were selected. They were classified into two groups according to the size of radiolucent area in the preoperative panoramic radiographs: in one group, it was larger than $3{\times}4cm$, while in the other group, it was smaller than $3{\times}4cm$. Follow-up panoramic radiographs were taken immediately after the surgery, then after 3, 6, 9 and 12 months. On those radiographs, changes in size and density of the defected areas were observed using the Gray-level histogram of Adobe photoshop v7.0. Correlation between bone regeneration and factors such as the type and size of the cysts, age, sex, site of the cysts and systemic disease was evaluated using the General repeated measure and Mann-Whitney Test. Results: Analyses of panoramic radiographs showed that the recovery of radiopacity after 12 months was more than 97% on average in defected areas that were smaller than $3{\times}4cm$. in the defected areas that were larger than $3{\times}4cm$, considerable portion showed recovery of radiopacity. No statistically significant change was observed in bone density according to the type of cysts. Young patients under 20 years of age with highly active metabolism presented more significant bone regeneration than patients over 20 years of age. Bone regeneration was more hampered in patients who had medical disease, compared with patients who didn’t have any medical problem. No statistically significant change was seen in bone density according to sex. Changes in bone density according to the site of cysts such as maxilla, mandible, anterior or posterior region were not considered to be significant. Conclusion: Analyses of panoramic radiographs suggest that in approximately 12 months after the enucleation of cysts, clinically acceptable spontaneous bone regeneration can be observed even though normal bone graft procedures have not been applied.

다층기판으로 구현된 마이크로스트립 선로와 결함접지구조의 초고주파 특성 및 등가회로 모델링 (A Study on the High Frequency Characteristics and Equivalent Circuit Model of Microstrip Lines Having Defected Ground Structures in Multilayer Substrates)

  • 오성민;구재진;박천선;황문수;안달;임종식
    • 한국산학기술학회논문지
    • /
    • 제7권6호
    • /
    • pp.1106-1115
    • /
    • 2006
  • 본 논문은 다층기판으로 구현된 마이크로스트립 전송선로와 여기에 결합된 결함접지구조의 초고주파 특성 및 모델링에 대하여 기술하고 있다. 단층 마이크로스트립 전송선로와 결함접지구조를 지닌 기본형 구조에, 제 2의 유전체 층을 결함접지구조가 있는 바닥 접지면 아래에 적층하여 다층기판 속의 결함접지구조를 형성하였다. 그리고 제2의 유전체 층의 유전율과 두께를 서로 달리해 가면서 초고주파 전송특성을 보고 추가된 유전체 층에 의한 등가회로의 변화를 등가회로 모델링을 통하여 분석하였다. 본 논문에서 제안된 방법에 따르면 적층된 제 2의 유전체 층에 의한 등가회로의 변화를 따로 확인할 수 있어서 추후 초고주파 회로에 유익하게 응용될 수 있다.

  • PDF

토끼 실험적 골 결손부에 이식한 이종 이식골편의 처리방법에 따른 신생골 형성능력 비교 (Comparison of Efficacy of New Bone Formation According to Implant Treatment in Xenograft Transplanted for Experimental Bone Defects of Rabbits)

  • 송하나;이종일
    • 한국임상수의학회지
    • /
    • 제24권3호
    • /
    • pp.350-357
    • /
    • 2007
  • Bone graft had been widely investigated for reconstruction of bone defects or acceleration of bone healing in orthopedics, neurosurgery and dental surgery. Autograft is the golden standard of bone graft but it is associated with donor site morbidity and is restricted in quantity. Xenograft has been researched an alternative method for autograft. The purpose of this study was to investigate the efficacy of new bone formation according to three different preparations of implants on rabbit xenograft. Cortical bone xenografts which made from bovine femoral cortical bone were treated by freezing, freeze-drying or defat-freezing implant preparations. They were transplanted into proximal diaphyseal shaft of bifibulae of 15 rabbits which were divided into three groups according to their implant preparation method. The fibulae transplantations were evaluated radiographically and examined osteoblast activity by bone alkaline phosphatase (BALP) biweekly for 16 weeks to observe new bone formation and union of the experimental defected region. New bone formation was observed in 7 cases in freeze-drying and defat-freezing group, respectively. Union of proximal and distal end of defected region, which was considered as success of bone graft, was observed in 4 cases (40%; 4 of 10 cases), respectively. In freezing group, new bone formation was observed in 6 cases but, there is no union observed. BALP value was increased over twice after two weeks of graft procedure in all union cases of freeze-drying and defat-freezing group (two of five animals, respectively) then gradually decreased to 16th week. In non-union cases, there is no significant variation in BALP value. Defat-freezing or freeze-drying preparations of implants are more efficacious in new bone formation than freezing method on rabbit xenograft. While it is difficult to propose which is superior between defat-freezing and freeze-drying, defatting of implants may enhance new bone formation in xenograft.

공통 결함접지구조를 이용한 소형화된 저역통과여파기의 설계 (Design of A Miniaturized Low Pass Filter Using Common Defected Ground Structure)

  • 이준;이재훈;임종식;안달
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2298-2304
    • /
    • 2011
  • 본 논문에서는 공통 결함접지구조(common defected ground structure, CDGS)를 이용한 초고주파 대역의 저역통과여파기(low pass filter, LPF) 소형화 설계에 대하여 기술한다. 기존의 연구에서는 표준형 LPF보다 약간 소형화된 DGS 적용의 LPF를 설계하는 방법을 제시하는데 그쳤으나, 본 논문에서는 공통 DGS 구조를 이용하여 종래의 회로보다 절반의 크기로 줄이는 방법을 제시한다. 공통 DGS는 양면의 마이크로스트립 전송선로의 공통 접지면에 구현된다. 본 논문에서는 예로써, 비유전율이 2.2이고 두께가 31mils인 유전체 기판을 이용하여 양면 마이크로스트립 전송선로 구조와 공통 DGS를 구성하고, 이를 활용하여 소형화된 LPF를 설계하고, 실제로 제작 및 측정하여 제안하는 방법의 타당성을 검증한다. 최종적으로 설계된, 공통 DGS를 지니는 LPF는 기존의 단층 구조에서 DGS를 지니는 LPF에 비하여 52.6%의 크기를 가지면서도, 측정된 성능은 반사계수가 -22dB 이하이고 삽입손실이 0.19dB 이하로 여전히 우수함을 보여준다.

국산 침엽수재 원판(圓板)의 진공건조(眞空乾燥) 특성 (I) (The Characteristics of Vacuum Drying Disks of Domestic Softwoods (I))

  • 이남호;이준호;김종만;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권2호
    • /
    • pp.46-54
    • /
    • 1996
  • This study was carried out to investigate the vacuum drying characteristics of 50mm- and 75mm- thick tree disks of some domestic softwoods for substituting the conventional hardwoods as the materials for wood crafts. Though the elapsed drying times from green to in-use moisture content(MC) were largely shortened by vacuum drying, the tree disks treated by EWS couldn't be dried to in-use MC, and so sapwood stains also were occurred severely. We suggest EWS treatment is undesirable for the species with very high sapwood portion or vacuum drying with hot water circulation heating system. Heart checks were slight, but sapwood checks, which have never been trouble in drying process of tree disks, were severe. For the reasonable explanation it is suggested MC differences between sapwood and heartwood were large and most of tree disks had already no barks before drying test. Ginkgo was vacuum-dried with very slight drying defects such as heart checks, sapwood checks. V-cracks and sapwood stains. In Korean red pine and pitch pine V-cracks were severely occurred. And it was found the special feature that most of these defected tree disks contained several V-cracks within one tree disk. It can be considered as the causes that the region of sapwood was defected by the several checks at the early drying stage because of the steep MC gradient along the radial direction, and then at the later drying stage the drying stresses due to differential shrinkage were concentrated on these brittle spots.

  • PDF

초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로) (Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements))

  • 이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.117-124
    • /
    • 2014
  • 본 연구는 초음파 진단 장치에서 초음파 프로브 소자의 결함이 도플러 영상에 미치는 영향을 평가한 것이다. 초음파 프로브 소자결함의 여러 유형 중에서 동일한 방식으로 단선된 초음파 프로브 소자 수를 변화하면서, 도플러 모드 영상에 미치는 영향을 실험으로 살펴보았다. 실험 결과는 첫째, 소자 결함에 따른 도플러 속도는 도플러 소자군 부분에서 급격히 변화하고 있으며, 혈류 속도에는 크게 영향을 받지 않는 것으로 나타났다. 둘째, 도플러 소자군 주변에서 결함 있을 때 소자의 번호가 높은 쪽 소자의 결함에 의한 효과가 작은 것을 알 수 있었다. 셋째, 팬텀의 혈류 속도가 높을수록 도플러 속도 스펙트럼의 폭은 커지지만 크기는 감소하고 있다. 그리고 결함이 증가할수록 도플러 속도와 영상의 밝기의 분산이 더 커지는 것으로 나타났다. 이는 프로브 소자의 결함이 증가하면 전체적으로 시간 평균 도플러 속도 프로파일(TADVP)의 크기가 감소하며 고주파수 영역에서 더 빨리 떨어지는 것으로 알 수 있다.

하악 체부에서 과두부까지 이환된 만성 화농성 골수염 환자의 보존적 외과술식을 이용한 치험례 (CONSERVATIVE TREATMENT OF CHRONIC SUPPURATIVE OSTEOMYELITIS ON MANDIBULAR BODY TO CONDYLE AREA: A CASE REPORT)

  • 이대정;최문기;오승환;이종복
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.474-480
    • /
    • 2009
  • These is a cases of chronic suppurative osteomyelitis occurred in the mandibular body to condyle of 48-year-old male patient. Extensive bone destruction was noted on the right mandibular body, angle, ascending ramus, mandibular notch and condylar region. We made a treatment plan that radicular mandibular resection from body to condyle and mandibular reconstruction with vascularized fibular flap at first time. But, we could observe marked bone regeneration with only mild curettage, local wound care and massive antibiotic therapy. So we preserved the anterior ramus portion of mandible. Defected mandibular condyle was reconstructed with costochondral graft. In this paper we present the case of a patient who has chronic osteomyelitis in mandibular area.

개에서 실험적 골결손 치유 반응에 대한 초음파 평가 (Ultrasonographic Evaluation of the Bone Beating of the Experimentally Induced Bone Defect in Dogs)

  • 박진희;성윤상;엄기동
    • 한국임상수의학회지
    • /
    • 제23권3호
    • /
    • pp.258-262
    • /
    • 2006
  • This study was performed to evaluate the usefulness of gray-scale and power Doppler ultrasonography, and to compare with radiography for detection of the repairing in experimentally induced bone defects in dogs. In 4 adult beagle dogs bilateral bone defects were created in 8 canine femurs as sized as 5 mm diameter. Mean detection time of the ultrasonographic endosteal callus formations(mean $14.25{\pm}2.31$ days) was significantly shorter than that of the radiographic opacity chanees(mean $23.50{\pm}2.27$ days) in the defected region. Mean time of the neovascularizd flow signal(mean $6.00{\pm}3.59$ days) from the power Doppler ultrasonographic examination was significantly shorter than that of gray-scale ultrasonographic findings. With these results, gray-scale ultransonography and power Doppler ultrasonography can be used for an early detection modality for bone healing.