• 제목/요약/키워드: Defect of insulation

검색결과 103건 처리시간 0.023초

PL에 근거한 LED 가로등의 결함 요소 발굴 및 분석 (Finding and Analysis of Defective Elements of an LED Streetlight Lamp Based on the Product Liability)

  • 김향곤;최충석
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.632-632
    • /
    • 2009
  • The purpose of this study is to present the range of defects mentioned in the Product Liability (PL) and to establish an objective basis and grounds for the analysis of accidents expected to happen by analyzing and presenting the external flame pattern and electrical characteristics of an LED streetlight lamp, a new lighting lamp. From the analysis of the cross-section of a cable carbonized by an external flame, it was observed that the wire's strand and insulation material had solidly adhered, and that greater voids were formed at the surface than at the center. Irregular carbide lumps were formed in the globe directly exposed to the flame, and the globe carbonized by the indirect flame showed characteristics that they had melted and flowed downward. It was found that the forward and backward resistances of the normal LED were approximately 1.74 [$M{\Omega}$] and 140 [$M{\Omega}$], respectively. The lamp burnt by the strong flame exhibited infinite forward and backward resistances and the LED did not emit light. The carbonized LED lamp was gray and exhibited fine delaminations. According to the Product Liability, a product defect signifies a simple product defect. Most of the defects were caused by the lack of stability, and the defect of the product itself occurred during the design and manufacture. The defects in warnings and markings include an insufficiency of handling manuals and warnings, expressive warranty violations, defective markings, etc. In order to prevent an accident resulting from a product, it is necessary to prepare safety warnings and documentation, establish clear-cut lines of liabilities, and subscribe insurances. However, it could be seen that important factors against the Product Liability were product improvement, response to compensation requests and law suits, credit restoration, etc.

깊은 준위 결함에 의한 SiC SBD 전기적 특성에 대한 영향 분석 (The effect of deep level defects in SiC on the electrical characteristics of Schottky barrier diode structures)

  • 이건희;변동욱;신명철;구상모
    • 전기전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.50-55
    • /
    • 2022
  • SiC는 차세대 전력반도체의 핵심 재료로 넓은 밴드갭과 높은 절연파괴강도, 열전도율을 가지고 있지만 deep level defect와 같은 다양한 문제를 야기하는 결함이 존재한다. SiC에서 나타나는 defect는 물성에서 나타나는 defect와 계면에서 나타나는 interface trap 2가지로 나뉜다. 본 논문은 상온 (300 K)에서 보고되는 Z1/2 trap concentration 0 ~ 9×1014 cm-3을 SiC substrate와 epi layer에 적용하여 turn-on 특성을 알아보고자 한다. 전류밀도와 SRH(Shockley-Read-Hall), Auger recombination을 통해 구조 내 재 결합률을 확인하였다. trap concentration이 증가할수록 turn-on시 전류밀도와 재 결합률은 감소하며 Ron은 0.004에서 0.022 mΩ으로 약 550% 증가하였다.

22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석 (Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable)

  • 김영석;김택희;김종민;송길목
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

이동형 전기기기의 감전재해 특성 및 그 대책 (The Characteristics of Electric Shock Accidents and Their Countermeasures for Portable Electrical Tools)

  • 최상원
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.21-26
    • /
    • 2017
  • According to the data of Korea Occupational Safety and Health Agency, electric shock accidents during recent 11 years exceeded more than 60% in architecture/other and construction work, the countermeasures for safety are required in the harsh environment of a construction site where moving electric machines and equipments are widely used. The establishment of countermeasure for insulation degradation and defect is required, in consideration of increasing trend for accidents caused by defective insulation among low voltage electrical installation each year. The aim of this study is to propose the policy about portable electrical tool standards and/or worker's safety standards for preventing electric shock accidents on safety workings, and is to develop the technology and the safety device to prevent electric shock for accident prevention reduction through experiments. It obtained the followings through this study; statistical data analysis of late about 10 years of electric shock-related industrial accidents analysis and portable electric tools; safety device development of 'device for testing continuous grounding and power shut-down' to prevent electric shock from portable electric tools. Furthermore, developed results and proposal in this study will help to prevent the electric shock accidents from portable electric tools and will be expected the utilization of policy formulation, educational data and field supplement of the safety device, and etc.

세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석 (Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

고압전동기 고정자 권선의 운전중 부분방전 패턴 분석 (Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings)

  • 김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

고압회전기 고정자 권선의 부분방전 측정 (Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings)

  • 김희동;이영준;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구 (Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition)

  • 최충석
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정 (Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable)

  • 박서준;황성철;왕국명;길경석
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.203-209
    • /
    • 2017
  • 전력공급의 안정성 및 신뢰도 향상을 위해 각종 전력설비의 예방진단에 관한 연구개발이 활발하다. 가스절연개폐장치와 변압기와 같은 단위 기기의 절연진단기술은 빠르게 발전하고 있으나, 전력케이블에 있어서는 단순히 결함의 유무와 부분방전을 측정할 뿐, 세부적 특성에 대해서는 거의 연구되고 있지 않다. 따라서 본 논문에서는 XLPE 케이블에서 보이드의 크기와 위치에 따른 부분방전 특성과 결함의 위치추정에 관한 연구를 수행하였다. 보이드의 크기 및 위치에 따른 4종의 결함계를 모의하였으며, 부분방전펄스는 주파수 대역 150kHz~30MHz의 고주파변류기로 검출하였다. 실험결과, 도체에 인접한 결함일수록 방전전하량이 크고, 정극성에 비해 부극성의 방전펄스 수가 약 20% 많게 나타났다. 또한 TDR 방법으로 결함위치를 산출하였으며, 50m 케이블에서 1m 이내로 결함의 위치를 추정할 수 있었다.