• Title/Summary/Keyword: Defect case

Search Result 1,693, Processing Time 0.025 seconds

Partial anomalous pulmonary venous connection with intact atrial septum in a child with ventricular septal defect: a case report

  • Kim, Young-Nam;Cho, Hwa-Jin;Cho, Young-Kuk;Ma, Jae-Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Partial anomalous pulmonary vein connection (PAPVC) is a rare congenital abnormal cardiac defect involving the pulmonary veins draining into the right atrium (RA) directly or indirectly by venous connection. Ninety percent of PAPVCs are accompanied by atrial septal defect (ASD). To our knowledge, there is no previous report of PAPVC with ventricular septal defect (VSD) without ASD in Korea, and in this paper, we report the first such case. A 2-day-old girl was admitted into the Chonnam National University Hospital for evaluation of a cardiac murmur. An echocardiogram revealed perimembranous VSD without ASD. She underwent patch closure of the VSD at 5 months of age. Although the VSD was completely closed, she had persistent cardiomegaly with right ventricular volume overload, as revealed by echocardiography. Three years later, cardiac catheterization and chest computed tomography revealed a PAPVC, with the right upper pulmonary vein draining into the right SVC. Therefore, correction of the PAPVC was surgically performed at 3 years of age. We conclude that it is important to suspect PAPVC in patients with right ventricular volume overload, but without ASD.

Effect of Welding Condition and Tool Shape on Defect Formation of Extruded AA6005 with Non-uniform Thickness using Load-Controlled Friction Stir Welding Technique (두께 불균일 AA6005 압출재의 하중제어 마찰교반접합에서 접합 조건과 툴 형상이 결함발생에 미치는 영향)

  • Yoon, Tae-Jin;Kang, Myung-Chang;Jung, Byong-Ho;Kang, Chung-Yun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.45-51
    • /
    • 2013
  • Friction stir welding using aluminum alloys has been widely applied for transportation vehicles because of the light specific weight, which can be used to obtain sound joint and high mechanical properties. This study shows the effects of rotation speed, welding speed, welding load, and tool shape on defect formation with extruded AA6005, which is used for railway vehicle structures of non-uniform thickness welded by friction stir welding using load control systems. Optical microscopy observations and liquid penetrant testing of each FSW joint were carried out in order to observe defect formation. Two kinds of defects, that of probe wear and that of lack of penetration in the bottom of the welded zone, were observed. In the case of using a taper shaped tool, the defect free zone is very narrow, within 100 kgf; however, in case of using a cylindrical shape tool, the defect free zone is wider.

Propagation Characteristic of Ultrasonic on Slit Defect in Butt Joint (맞대기 용접부내의 인공 결함에서 초음파의 전파특성)

  • 남영현
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.37-47
    • /
    • 1996
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is related to determination of testing sensitivity, scanning pitch and defect location. This paper investigated the directivity of ultrasonic wave, which scattered from slit defect located in heat-affected zone (HAZ) in butt joint using visualization method. The directivity of shear waves scattered from slit defect were different according to probe direction (far defect, near defect) and probe position (forward movement, maximum echo position, backward movement). The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. In the case of 2 MHz angle probe, the directivity of reflection wave was appeared sharp form because of the relation wave length and defect size.

  • PDF

Surgical Treatment of Left Ventricular-Right Atrial Shunt (좌심실-우심방 단락의 외과적 치료)

  • 이응배;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.945-950
    • /
    • 1996
  • Twelve patients with left ventricular-right atrial shunt (LV-RA shunt) underwent surgical correction be- tween April 1982 and March 1995. Seven patients were male and five patients were female. Age ranged from 3 to 26 years with mean age of 8.5 years. On the preoperative chest PA views, increased pulmonary vascularity was noted in 3 cases and enlargement of right atrium in 4 cases. The mean preoperative cardiothoracic ratio was 0.59. Echocardiographic studies were obtained in 9 patients and the preoperative echocardiographic diagnoses were LV-RA shunt in 2 cases, ventricular septal defect (VSD) in 6 casei, and atrial septal defect (ASD) in 1 case. The preoperative ngiographic diagnoses which were obtained in all patients were LV-RA shunt in 5 cases, VSD in 5 cases, ASD in 1 case, and VSD with ASD in 1 case. The descriptions of defect of LV-RA shunt according to intraoperative findings were supravalvular defect in 5 cases(42%), infravalvular defect in 4 cases (33%), and combined defect in 3 cases (25%). Associated anomalies of tricuspid valve in 4 cases of infravalvular defect were perforation (3 cases) and cleft (1 case). Primary closure of the septal defect was performed through the right atriotomy in all but one patient. There was no operative death. One patient underwent reoperation because of the residual interventricular shunt. All patients have been in good condition.

  • PDF

A Study on Analysis on an Automotive Fire Case that Broke Out due to an Electrical Cause during Engine Stopping (엔진정지 중 전기적인 원인에 의해 발생한 자동차화재의 분석 연구)

  • Lee, Euipyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 2013
  • Although it is widely accepted that a fire can occur due to electrical causes even when an engine stops, there is little introduction of detailed case analysis. This study analyzed a fire case caused by an electrical cause during engine stopping at parking lot in detail. Moreover, it was revealed that the fire was mainly caused by design defect.

Ruptured Sinus of Valsalva Aneurysm - A Case Report - (대동맥동 동맥류 파열 - 1례 보고 -)

  • Kim, Seong-Su;Jo, Jung-Gu;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.687-692
    • /
    • 1989
  • Aneurysm of the sinus of Valsalva is an uncommon cardiac anomaly, usually congenital in origin, which may occur as an isolated defect or in conjunction with other cardiac malformation. This report is a case of a ruptured sinus of Valsalva aneurysm with ventricular septal defect in a 18-year-old female patient who complained progressive exertional dyspnea. She underwent operative management using total cardiopulmonary bypass. The fistula originated from the right coronary sinus and ruptured into the right ventricle and coexistent lesion was supracristal ventricular septal defect. The repair was done through aortic and right ventricular approach. The ruptured sinus of Valsalva was closed with pledget suture and the ventricular septal defect was closed with patch. The postoperative result was good.

  • PDF

Tetralogy of Fallot with Subpulmonary Ventricular Septal Defect: A Case Report (Subpulmonary VSD 를 동반한 활로 4증: 수술 치험 1례 보고)

  • 우종수
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.175-180
    • /
    • 1978
  • A rare form of tetralogy of Fallot, in which large ventricular septal defect was located at subpulmonary position rather than beneath a well developed crista supraventricularis was operated in this Department. This case satisfied the criteria for the diagnosis of tetralogy of Fallot, having large ventricular septal defect beneath the aortic valve with overriding of aorta, pulmonary stenosis and right ventricular hypeFtrophy. The operation was done through a median sternotomy using cardiopulmonary bypass. A vertical right ventriculotomy was extended to the pulmonary valve ring. Pulmonary and aortic valve were adjacent to each other, in contrast to the situation of classic tetralogy of Fallot. Pulmonary valvulotomy was done and ventricular septal defect was closed. with Teflon, and right ventricular outflow tract was reconstructed with woven Dacron covered by pericardial patch after minimal resection of septal band. The post-operatiove courses was uneventful except wound infection. The patient was discharged 15 days after open heart surgery.

  • PDF

Transient carnitine transport defect with cholestatic jaundice: report of one case in a premature baby

  • Cho, Hyun-Seok;Choo, Young-Kwang;Lee, Hong-Jin;Lee, Hyeon-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.2
    • /
    • pp.58-62
    • /
    • 2012
  • Carnitine (${\beta}$-hydroxy-${\gamma}$-trimethylaminobutyric acid) is involved in the transport of long-chain fatty acids into the mitochondrial matrix and the removal of potentially toxic acylcarnitine esters. Transient carnitine transport defect is a rare condition in newborns reported in 1/90,000 live births. In this paper, we describe a case of transient carnitine transport defect found in a premature baby who had prolonged cholestatic jaundice and poor weight gain, and who responded dramatically to oral carnitine supplementation.

Mode conversion in nondestructive nonlinear acoustic method for defect detection in a layer-structured material

  • Roh Heui-Seol;Yoon Suk Wang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.219-222
    • /
    • 2001
  • Nondestructive nonlinear acoustic method in two dimensions is suggested as a useful tool for detecting defects in a composite layer-structured material. Spectrum level changes in fundamental and harmonic frequencies are observed in the presence of a layer type defect compared with in the absence of such a defect. It is proposed in this study that such spectrum changes we due to the mode conversion. The layer type defect makes different normal modes due to different boundary conditions in the thickness direction for the Lamb waves propagating in a layer-structured material. Specifically, the normal mode with the fundamental frequency in the case of the water-layer gap is converted to the normal mode with the second harmonic frequency in the case of the air-layer gap.

  • PDF

Double Orifice Mitral Valve in Atrioventricular Septal Defect -Report of One Case- (심내막 결손증에 동반된 중복 승모판구 -1례 보고-)

  • 최필조
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.234-237
    • /
    • 1994
  • We report a case of double orifice mitral valve complicating a partial atrioventricular septal defect.The preoperative diagnosis was suggested by a characteristic angiographic and echocardiographic findings but the correct diagnosis of double orifice mitral valve itself was proven by open heart surgery. The smaller accessory mitral orifice was located in the left lateral leaflet and was left untouched. The A-V septal defect was closed with Gore-Tex patch and localized tricuspid annuloplasty was done using Gore-Tex tubular graft for correction of severe tricuspid regurgitation. The anterior mitral cleft left intact had mild mitral regurgitation on postoperative echocardiography.Postoperative course was uneventful and the patient was discharged 2 weeks later.

  • PDF