Autoencoder Based N-Segmentation Frequency Domain Anomaly Detection for Optimization of Facility Defect Identification (설비 결함 식별 최적화를 위한 오토인코더 기반 N 분할 주파수 영역 이상 탐지)

  • Kichang Park;Yongkwan Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.3
    • /
    • pp.130-139
    • /
    • 2024
  • Artificial intelligence models are being used to detect facility anomalies using physics data such as vibration, current, and temperature for predictive maintenance in the manufacturing industry. Since the types of facility anomalies, such as facility defects and failures, anomaly detection methods using autoencoder-based unsupervised learning models have been mainly applied. Normal or abnormal facility conditions can be effectively classified using the reconstruction error of the autoencoder, but there is a limit to identifying facility anomalies specifically. When facility anomalies such as unbalance, misalignment, and looseness occur, the facility vibration frequency shows a pattern different from the normal state in a specific frequency range. This paper presents an N-segmentation anomaly detection method that performs anomaly detection by dividing the entire vibration frequency range into N regions. Experiments on nine kinds of anomaly data with different frequencies and amplitudes using vibration data from a compressor showed better performance when N-segmentation was applied. The proposed method helps materialize them after detecting facility anomalies.

Pulmonary Embolism In Childhood Minimal Change Nephrotic Syndrome (소아 미세변화 신증후군에서 폐색전증에 대한 연구)

  • Sung, Seung-Joon;Hong, Ki-Woong;Kim, Eun-Ryoung;Kim, Il-Soo;Cho, Byung-Soo
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.100-108
    • /
    • 2001
  • Purpose : We investigated the incidence and predisposing factors of pulmonary embolism in minimal change nephrotic syndrome(MCNS). Methods : Lung perfusion scan using 99mTC-MAA were done on 14 patients who were diagnosed to minimal change nephrotic syndrome. Group h: Five patients who had perfusion defects on scan, Group B; Nine patients who had no perfusion defect on scan. Between the two groups, the differences of platelet number, hematocrits, albumin, cholesterol, triglyceride, proteinuria were evaluated. Results : Five patients were found to have perfusion defect consistent with pulmonary embolism($35.7\%$). However, there were minimal or no respiratory symptoms and signs. In our laboratory studies, the mean proteinuria on admissions was $676{\pm}31\;mg/m2/hr$ in the group with pulmonary embolism, and $313{\pm}28\;mg/m2/hr$ in the group without pulmonary embolism. There were more severe proteinuria in group with pulmonary embolism(P<0.05). The mean platelet count at early stage of remission after steroid treatment was $746,600{\pm}280,000/mm3$ in the group with pulmonary embolism, $511,890{\pm}90,000/mm3$ in the group without pulmonary embolism. There were significant difference of platelet count between the two groups(P<0.01). In patients with pulmonary embolism, there were more higher and sustained increasement of platelet count. All cases of pulmonary embolism were treated with dipyridamole(5 mg/kg). In 4 cases the perfusion defects were improved in two weeks, however, one case showed persistent perfusion defect after 1 month. Conclusion : Our study suggested that pulmonry embolism might be one of tile major complications in childhood MCNS The occurrence rate was correlated with severity of proteinuria before treatment and sustained increasement of platelet counts in early remission state after steroid treatment. Therefore, the scintigraphic pulmonary perfusion study is mandatory in childhood MCNS, especially in the high risk patients, such as the patients with severe proteinuria and sustained increasement of platelet count. (J Korean Soc Pediatr Nephrol 2001;5 : 100-8)

  • PDF

Differentiation between Morgagni Hernia and Pleuropericardial Fat with Using CT Findings (CT 소견을 이용한 Morgagni 탈장과 심막주위지방의 감별)

  • Kim Sung-Jin;Cho Beum-Sang;Lee Seung-Young;Bae Il-Hun;Han Ki-Seok;Lee Ki-Man;Hong Jong-Myeon
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.573-578
    • /
    • 2006
  • Background: Generally hernia is diagnosed with simple chest or gastrointestinal x-ray. Sometimes CT or MRI can give lots of information for the diagnosis. However, there was no study for the differentiation with using CT findings between Morgagni hernia and pleuropericardial fat. The aim of this study was to evaluate the useful CT findings for differentiating Morgagni hernia from pleuropericardial fat. Material and Method: We retrospectively analyzed CT scans of eight patients with Morgagni hernia and 20 patients with abundant pleuropericardial fat without peridiaphragmatic lesions. All CT scans were performed with coverage of the whole diaphragm in the inspiration state. We evaluated 1) the presence of the defect of the anterior diaphragm, 2) the interface between the lung and fat, 3) the angle between the chest wall and fat, 4) the continuity between the extrapleural fat and fat, 5) the presence of the vessels within fat, and 6) the presence of a thin line surrounding fat. Result: In all cases with Morgagni hernia, the defect of the anterior diaphragm was seen. The interface was well-defined, smooth, and convex to the lung. The angle with the chest wall was acute. The continuity with the extrapleural fat was not seen. In the cases with abundant pleuropericardial fat, the defect of the anterior diaphragm was seen in three (15%). The interface was usually irregular (n=10) and flat (n=17). The angle with the chest wall was variable. The continuity with the extrapleural fat, that was markedly increased in amount, was usually seen (n=16). The thin line surrounding fat was seen in four cases with Morgagni hernia, however, not seen in all cases with pleuropericardial fat. All of the above findings were statistically significant, however, vessels within fat was not significant to differentiate Morgagni hernia (n=8/8) from pleuropericardial fat (n=14/20). Conclusion: The useful CT findings of Morgagni hernia were fatty mass with sharp margin, convexity toward lung, acute angle with chest wall, and thin line surrounding hernia. Branching structure within fatty mass representing omental vessels that has been known as a characteristic finding of Morgagni hernia was not useful for differentiating Morgagni hernia from pleuropericardial fat.

A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image (Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구)

  • Lee Eun-Kyoung;Yu Seung-Hyun;Lee Su-Kyung;Kang Sung-Ho;Han Jong-Min;Chong Myong-Soo;Chun Eun-Joo;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

The Physicochemical and Optical Characteristics of FeaSibCcHd Films (FeaSibCcHd 박막의 물리·화학 및 광학적 특성)

  • Kim, Kyung-soo;Jean, Bup-Ju;Jung, Il-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.105-111
    • /
    • 1999
  • When the preparation method of iron silicide films possess the annealing process, the interfacial state of the films is not fine. The good quality films were obtained as the plasma was used without annealing processing. Since the injected precursors were various active species in the plasma state, the organic compound was contained in the prepared films. We confirmed the formation of Fe-Si bonds as well as the organic compound by Fe and Si vibration mode in Raman scattering spectrum at $250cm^{-1}$ and Ft-IR. Because of epitaxy growth being progressed by the high energy of plasma at the low temperature of substrate, iron silicide was epitaxially grown to ${\beta}$-phase that had lattice structure such as [220]/[202] and [115]. Band gap of the prepared films had value of 1.182~1.174 eV and optical gap energy was shown value of 3.4~3.7 eV. The Urbach tail and the sub-band-gap absorptions were appeared by organic compound in films. We knew that the prepared films by plasma were obtained a good quality films because of being grown single crystal.

  • PDF

Implementation of Power Cable Diagnostic Simulator using VLF (VLF를 활용한 전력케이블 진단 시뮬레이터 구현)

  • Kim, Kuk;Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.593-602
    • /
    • 2020
  • Power cables installed in domestic factories or underground can cause accidents depending on the manufacturing process, installation, and environmental conditions during use. When an accident occurs in a power cable, it can cause enormous economic loss and social confusion. Hence, the importance of preventive management of the cable through diagnosis is increasing to prevent it. Therefore, in this paper, a diagnostic sample cable was produced by simulating a part that could be a problem due to the installation, manufacturing defects, or deterioration of cables that can occur in the field. Dielectric loss Tangent (tan 𝛿; TD), and Partial Discharge(PD) tests were performed. Partial discharge and AC (60Hz) withstand voltage equipment using High-Frequency Current Transformer (HFCT) were applied After applying a VLF (Very Low Frequency) power supply with a frequency of 0.1Hz was applied. As a result, B and C phase defect samples at a 2.0U0 voltage through the VLF could measure the internal partial discharge in the A-phase normal sample cable from the noise at a 0.5U0 to 2.0U0 voltage. In addition, the 1.5U0 voltage was measured through the AC (60Hz) withstand voltage equipment of the commercial frequency to verify its effectiveness. Partial discharge in the run-off state was measured at a voltage of 1.0U0, and there was a risk when installing the equipment. AC power equipment showed a difficulty of movement by volume or weight. The diagnostic method, through the VLF of the quadrant state, revealed its safety and effectiveness.

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

Current State of Carcass Weight Distribution and External Quality from Domestic Product Duck (국내에서 유통되고 있는 오리의 도체중량 분포 및 도체품질 현황)

  • Kang, Geun-Ho;Chae, Hyun-Seok;Park, Beom-Young;Cho, Soo-Hyun;Seong, Pil-Nam;Jeong, Seok-Geun;Kim, Dong-Hun
    • Food Science of Animal Resources
    • /
    • v.31 no.2
    • /
    • pp.266-272
    • /
    • 2011
  • The objective of this study was to investigate the current state of carcass weight distribution and external quality of domestic duck products. A total of 419,164 duck heads were used for the carcass weight distribution analysis. From the results, the average, mode, median, and quartile were 2,164.4, 2,000, 2,200, and 300 g, respectively. Furthermore, carcass yield averaged 70.1% from the live weights of domestic duck products. Duck carcasses had 28.4% external defects and 4.8% external damage. Moreover, the appearance ratio of discoloration was 34.1% and, in particular, the leg region was significantly (p<0.05) higher than that of the other regions. The feather removal defect ratio averaged 44% from the duck carcass surface. The ratio of disjointed and broken bones averaged 9.91% and mostly appeared in wing and leg parts. Fat content was significantly (p<0.05) higher in carcasses with weights >2.3 kg than that of other carcass weight levels, suggesting that market live weight of domestic duck products must be greater than a minimum of 3 kg.

Investigation of Spherical LiMn2O4 Cathode Materials by Spray-drying with Different Electrochemical Behaviors at High Rate (분무건조법으로 제조한 구형 스피넬계 LiMn2O4 양극소재의 합성 조건에 따른 고출력 거동에 대한 연구)

  • Song, Jun Ho;Cho, Woosuk;Kim, Young Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.2
    • /
    • pp.50-56
    • /
    • 2016
  • Spherical lithium manganese oxide spinel, $Li_{1.10}Mn_{1.86}Al_{0.02}Mg_{0.02}O_4$ was prepared by wet-milling, spray-drying, and sintering process. In the spray-drying process, solid content in slurry was varied from 20 to 30 wt%. In the sintering process, the precursors have been sintered under air or $O_2$ atmosphere. While the as-prepared samples exhibit excellent electrochemical properties at room temperature, the discharge voltage profiles at 5.0C are very different one from another. The origin for the difference especially at initial state of discharge is oxygen defect. The sample prepared in air has larger capacity related to the plateau at 3.3 V (vs. $Li/Li^+$) which is caused by the oxygen defects than the one prepared in $O_2$. The difference of discharge voltage profiles especially at the final state of discharge comes from different diffusion rate of $Li^+$ ions. The sample prepared from 30 wt% solid content of slurry shows twice higher diffusion rate than the samples prepared from 20 wt% solid content, which is attributed to better compactness between primary particles for the sample prepared from 30wt % solid content than the one prepared by 20 wt%.

Learning for Environment and Behavior Pattern Using Recurrent Modular Neural Network Based on Estimated Emotion (감정평가에 기반한 환경과 행동패턴 학습을 위한 궤환 모듈라 네트워크)

  • Kim, Seong-Joo;Choi, Woo-Kyung;Kim, Yong-Min;Jeon, Hong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.1
    • /
    • pp.9-14
    • /
    • 2004
  • Rational sense is affected by emotion. If we add the factor of estimated emotion by environment information into robots, we may get more intelligent and human-friendly robots. However, various sensory information and pattern classification are prescribed for robots to learn emotion so that the networks are suitable for the necessity of robots. Neural network has superior ability to extract character of system but neural network has defect of temporal cross talk and local minimum convergence. To solve the defects, many kinds of modular neural networks have been proposed because they divide a complex problem into simple several subproblems. The modular neural network, introduced by Jacobs and Jordan, shows an excellent ability of recomposition and recombination of complex work. On the other hand, the recurrent network acquires state representations and representations of state make the recurrent neural network suitable for diverse applications such as nonlinear prediction and modeling. In this paper, we applied recurrent network for the expert network in the modular neural network structure to learn data pattern based on emotional assessment. To show the performance of the proposed network, simulation of learning the environment and behavior pattern is proceeded with the real time implementation. The given problem is very complex and has too many cases to learn. The result will show the performance and good ability of the proposed network and will be compared with the result of other method, general modular neural network.