• Title/Summary/Keyword: Defect Possibility

Search Result 218, Processing Time 0.032 seconds

Prospective Study on the Development of Glaucoma after Interferon alfa Therapy for Chronic Hepatitis B (만성 B형 간염 환자에서 인터페론 치료 후 녹내장 발생 여부의 전향적 연구)

  • Kwon, Young-Se;Choe, Yon-Ho;Hong, Sung-Bum
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.2
    • /
    • pp.169-174
    • /
    • 2000
  • Purpose: Previously reported ocular complications of interferon alfa administration are extremely rare. We experienced a 15-year-old boy with chronic hepatitis B who developed glaucoma after interferon alfa therapy. The purpose of this prospective study was to evaluate the possible development of glaucoma after interferon alfa therapy for chronic hepatitis B. Methods: Nine patients with chronic hepatitis B who visited Inha university hospital between February 1998 and July 1999 received interferon alfa therapy. We measured visual acuity, intraocular pressure, C/D ratio, and visual field examination at pre-interferon therapy, three and six months after therapy, respectively. Results: The total number of patients was 9 (4 boys and 5 girls). Mean age was $11.7{\pm}4.1$ years. The duration of therapy was 6 months and mean dosage of interferon was 5 million units. Compared with visual acuity, intraocular pressure, and C/D ratio at pre-therapy, those parameters at 3 months and 6 months after therapy showed no significant differences and none showed visual field defect after therapy. Conclusion: Our prospective study showed no evidence of development of glaucoma after interferon therapy. However, it is necessary to be concerned about the possibility of developing glaucoma or other ophthalmologic diseases after interferon therapy in chronic hepatitis B.

  • PDF

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Comparison of Mechanical properties and Surface Friction of White Metals Produced by Centrifugal and Laser Cladded on SCM440 (원심주조방식과 레이저 클래딩 증착법을 통한 화이트메탈의 기계 및 마찰특성 비교)

  • Jeong, Jae-Il;Kim, Dong-Hyuk;Park, Jin-Young;Oh, Joo-Young;Choi, Si-Geun;Kim, Seock-Sam;Cho, Young Tae;Lee, Ho;Ham, Seung-Sik;Kim, Jong-Hyoung
    • Tribology and Lubricants
    • /
    • v.34 no.3
    • /
    • pp.84-92
    • /
    • 2018
  • Bearings are essential for reducing vibration and wear, in order to achieve high durability and increase longevity. White metal treatment of tilting pads via centrifugal casting method has the possibility of increasing durability. However, this manufacturing method has drawbacks such as long processing time, high defect rate, and harmful health effects. Laser cladding deposition technique is a powerful method that can address these issues by decreasing the processing time and providing good adhesion. In this study, we suggest optimum conditions for laser cladding deposition that can be used in industrial applications. We deposited a soft white metal layer on SCM440 that is primarily used in shafts to minimize wear of bearing pads. During the laser deposition process, we controlled factors such as laser power, powder feed rate, and laser head speed to determine the optimum conditions. In addition, we measured the hardness using micro Vickers, and performed field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and friction tests to investigate the mechanical properties and surface characteristics for different parameters. Based on the experimental results, we suggest that laser power, powder feed rate, and laser head speed of 1.3 kW, 2.5 rpm, and 10 mm/s, respectively, constitute the optimum conditions for producing white metals using laser cladding.

Surgical treatment on the stenosis of the esophagus (식도섬책에 대한 외과적 치료)

  • Kim, Geun-Ho;Kim, Yeong-Hak
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.134-140
    • /
    • 1989
  • A clinical evaluation was made on total 207 cases of corrosive esophageal stricture after ingestion of various corrosive substances and 173 cases of neoplasms in the esophagus and the cardia. The various complications associated with esophageal corrosion were observed on 28 cases [13.5%] in a total of 207 cases. Pathoanatomic findings of complication may be classified to the five category as follow; [1] stenosis in the pharynx due to adhesion of the epiglottis, [2] esophagobronchial fistula, [3] esophageal perforation with bougienation, [4] necrotic rupture of the esophagus and the stomach, and [5] so-called chronic corrosive gastritis. The comparative studies were done on a total of 165 cases of the various procedures of esophagoplasty to the reconstruction of the esophagus, which consists of antethoracal esophagoplasty with jejunum, retrosternal esophagoplasty with jejunum, retrosternal esophagoplasty with right colon, and retrosternal esophagoplasty with left colon. There is no hard and fast rule in selection of jejunum, right colon or left colon as the transplanting bowel and an operative method either antethoracal or retrosternal approach. When there was no possibility of the complication and no any defect of the anatomical states, one stage retrosternal esophagoplasty using right colon was better in various points of view. The 173 patients of the neoplasm of the esophagus consist of 28 cases of benign tumors and 145 cases of malignant tumors in the esophagus and cardia. 28 cases of benign tumors in the esophagus received the surgical treatment and they obtained with excellent results postoperatively. Of the 145 patients of esophageal carcinoma who received surgical managements, 101 cases [69.6%] were found to be operable and 44 cases [30.3%] were inoperable. Due to the various level of carcinoma in the esophagus, the following different surgical procedure was properly used case by case to get the best results in each case. Esophageal carcinoma in the upper and middle third segment received the total esophagectomy and the reconstruction of the esophagus using right colon by substernal procedure. Esophageal carcinoma in the lower third segment received an esophagojejunostomy in the mediastinum after the resection of lower third segment of the esophagus. Carcinoma in the esophago cardia and the stomach received also an esophagojejunostomy after the resection of the lower third segment of the esophagus and subtotal gastrectomy. For the 44 patients with inoperable carcinoma, the several palliative surgical managements such as gastrostomy or jejunostomy for feeding and esophagojejunostomy for bypass of the lower esophagus and the stomach were properly performed case by case for their maximum improvement.

  • PDF

Out-of-plane Deformation Measurement of Spherical Glasses Lens Using ESPI (ESPI를 이용한 구면 안경렌즈의 면외 변형 측정)

  • Yang, Seung-Pill;Kim, Kyoung-Suk;Jang, Ho-Sub;Kim, Hyun-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.77-81
    • /
    • 2007
  • The spherical lens is typically classified by the refractive power into two groups such as (+) diopter lens and (-) diopter lens. The deformation occurred by the external force that is applied to a lens is caused by the increase or the decrease in the diopter of a lens. In this paper, the deformation of the lens was quantitatively measured by using ESPI (Electronic Speckle Pattern Interferometry) which have been used in the optical measurement field for past few years. ESPI has an advantage that the deformation of an object can be measured precisely by using coherence of the light. The experiment was carried out to the totally 16 types of plastic lens. It was confirmed that the deformation was decreased by increasing the diopter of the lens when same displacement was applied to the lens in case of (+) diopter lens and was increased by decreasing the diopter of the lens in case of (-) diopter lens. Also, it was found that the deformation of (+) diopter lens is less than that of (-) diopter lens. Therefore, with these results, it is expected that the possibility of the quantitative measurement for variation of the optical defect caused by the deformation of a lens when the deformation is occurred to the various types of the lens can be presented and that the application in the lens industrial field can be performed.

  • PDF

The Indication of Ankle Lateral Ligament Reconstruction Using Tendon Graft in Chronic Ankle Instability (만성 족관절 불안정증에서 건이식을 이용한 외측 인대 재건술의 적응증)

  • Park, Jae Yong;Choi, Gi-Won;Cho, Jae-ho;Kang, Chan;Choi, Kyungjin;Chung, Jin-Wha;Kim, Hak Jun;Bae, Su-Young;Cha, Seung-Do;Kim, Ki Chun;Han, Seung Hwan;The Insurance Committee of Korean Foot and Ankle Society
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.1
    • /
    • pp.12-18
    • /
    • 2016
  • Purpose: The purpose of this study is to review the indications of ankle lateral complex reconstruction using tendon graft. Materials and Methods: We searched PubMed using the index, "ankle, instability, lateral ligament, reconstruction" from 1990 to present (September 30, 2015). We excluded 1) modified Brőstrom operation (MBO), 2) conventional tenodesis surgery, 3) review article, 4) technical note, and 5) articles written in another foreign language. We reviewed 24 papers through the publication events, operational method, the indications of surgery, and the specific features of the patient group. Results: There were the indications of 1) previous ligament surgery failure, 2) situation when ligament repair is impossible due to the ligament defect, 3) severe instability (preoperative talar tilt >$15^{\circ}$, anterior draw >10 mm or the difference of contralateral side talar tilt >$5^{\circ}$, anterior draw >3 mm), and 4) overweight (body mass index >$30kg/m^2$). Other considerations included 1) generalized joint laxity and 2) workers, highly-demanded or athlete highly-affected by instability. Conclusion: The ankle lateral complex reconstruction using tendon graft could be indicated in patients with the possibility of MBO failure with several considerations.

Control of Graphene's Electrical Properties by Chemical Doping Methods

  • Lee, Seung-Hwan;Choi, Min-Sup;La, Chang-Ho;Yoo, Won-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.119-119
    • /
    • 2011
  • This study examined the synthesis of large area graphene and the change of its characteristics depending on the ratio of CH4/H2 by using the thermal CVD methods and performed the experiments to control the electron-hole conduction and Dirac-point of graphene by using chemical doping methods. Firstly, with regard to the characteristics of the large area graphene depending on the ratio of CH4/H2, hydrophobic characteristics of the graphene changed to hydrophilic characteristics as the ratio of CH4/H2 reduces. The angle of contact also increased to 78$^{\circ}$ from 58$^{\circ}$. According to the results of Raman spectroscopy showing the degree of defect, the ratio of I(D)/I(G) increases to 0.42% from 0.25% and the surface resistance also increased to 950 ${\Omega}$ from 750 ${\Omega}$/sq. As for the graphene synthesis at the high temperature of 1,000$^{\circ}$ by using CH4/H2 in a Cu-Foil, the possibility of graphene formation was determined as a function of the ratio of H2 included in the fixed quantity of CH4 as per specifications of every equipment. It was observed that the excessive amount of H2 prevented graphene from forming, as extra H-atoms and molecules activated the reaction to C-bond of graphene. Secondly, in the experiment for the electron-hole conduction and the Dirac-point of graphene using the chemical doping method, the shift of Dirac-point and the change in the electron-hole conduction were observed for both the N-type (PEI) and the P-type (Diazonium) dopings. The ID-VG results show that, for the N-type (PEI) doped graphene, Dirac-point shifted to the left (-voltage direction) by 90V at an hour and by 130 V at 2 hours respectively, compared to the pristine graphene. Carrier mobility was also reduced by 1,600 cm2/Vs (1 hour) and 1,100 cm2/Vs (2 hours), compared to the maximum hole mobility of the pristine graphene.

  • PDF

Reconstruction of Electrical Burned Hand by Posterior Tibial Arterial Free Flap (후경골 동맥 유리 피판에 의한 수부 전기 화상의 재건)

  • Choi, Soo-Joong;Seo, Eun Min;Lee, Chang Ju;Chang, Jun Dong;Kim, Suk Wu;Lee, Sang Hun;Lee, Dong Hun;Seo, Young jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.14-23
    • /
    • 2004
  • Introduction: The hand and wrist are particularly susceptible to electrical burn. Skin defect with damage or exposure of underlying vital structure requires coverage by skin flap especially in case of the need for late reconstruction. We are reporting 4 cases of electrical burned hand treated by posterior tibial arterial free flap. The commonly used skin flaps such as scapular flap or groin flap are too bulky so that they are not satisfactory in function and cosmetic appearance. So we tried to cover them with a more thin skin flap. Materials and Method: From January 2002 to June 2003, four cases of hand and wrist electrical burn were covered using posterior tibial arterial free flap. All the cases were due to high voltage electrical burn. Age ranged from 31 years to 38 years old and all the cases were male patients. Recipient sites were 2 wrist, one thenar area and one knuckle of 2.3rd MP joint. Additional procedures were flexor tenolysis (simultaneous), FPL tenolysis and digital nerve graft (later) and extensor tendon reconstruction (later). Result: All the flap have survived totally without any complication including circulatory concern about the donar foot. Posterior tibail arterial free flap was so thin that debulking procedure was not required. Conclusion: For skin coverage of the hand & wrist region, posterior tibial arterial free flap have many advantages such as reliable anatomy, easy dissection and easy anastmosis with radial or ulnar artery and possibility of sensory flap. The most helpful advantage for hand coverage is its thinness. So we think this flap is one of the very useful armamentarium for reconstructive hand surgery.

  • PDF

Study on Stable Use of Stainless EAF Oxidizing Slag as Fine Aggregate of Concrete (스테인리스 전기로 산화슬래그의 콘크리트용 잔골재 활용방안 검토)

  • Cho, Bong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.133-142
    • /
    • 2014
  • Recently, more focus is shift to imbalances in aggregate market supply and demand and an exhaustion of natural resources. In this situation, Electric arc furnace oxidizing slag (EAF Slag) has high application possibility as aggregate for concrete due to similar property with general aggregate. In this study, We've got the plan to assure the chemical stability of EAF Slag, and then experimentally tested the mechanical performance and durability for the fine aggregate used EAF Slag. On this test result, we suggest the application plan. At the result of this study, it shows that EAF slag would reduce the surface defect such as pop-out due to natural aging for the fixed hour and adjustment the grain size of EAF Slag. And mechanical performance and durability according to the replacement rate of concrete service, were revealed more than equal or equal compare to general aggregate. Hereafter, quality control must precede not to impede the beauty of concrete surface as assure the safety for aging and processing. And, to establish the environmental resource recycling system for by-products of steel, it should be made development of various application and guideline of quality control for the EAF slag aggregate. Moreover, it must be constantly studied all kind of engineering performance and durability for related to this study.

NECROSIS OF ALVEOLAR BONE BY FORMOCRESOL : CASE REPORT (Formocresol에 의한 치조골 괴사의 치험례)

  • Park, Cheol-Hong;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.657-661
    • /
    • 2005
  • Various chemotherapeutic agents have been recommended for pulpotomy of primary teeth, and there are formocresol, ferric sulfate, and calcium hydroxide. Of those, formocresol has fixation effect of pulp tissue and high clinical success rate, so it is most commonly used agent. But formocresol has strong cytotoxic effects, thus many articles reported displacement and loss of permanent successor, amelogenesis imperfecta, mutation by general absorption, possibility of cancer induction. Recently, it has been reported that leakage by imperfect temporary sealing when FC-soaked cotton was inserted into the root canal caused necrosis of surrounding tissues. and that necrosis of alveolar bone related to the use of excessive formocresol. In this case, 2nd primary molar of upper left jaw was treated using formocresol in local clinic, but extracted because of lasting pain. Furthermore, symptoms didn't disappear so patient was refered to us. The patient was 8-year-old male, had foul odor from oral cavity and circular alveolar bone necrosis around the permanent successor' crown. Thus sequestrectomy was operated and observed through 19 months after operation, we found normal root development of permanent successor but no complete regeneration of alveolar bone defect and attached gingiva. Lesion of periodontal tissues by formocresol is irreversible, so we have to confirm the indication in using formocresol and pay attention to complete temporary sealing.

  • PDF