• Title/Summary/Keyword: Defect Imaging

Search Result 267, Processing Time 0.029 seconds

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.

Visual Evoked Potentials in Retrochiasmal Lesion; Correlation with Neuroimaging Study (시각유발전위 검사상 후-시신경교차부위병변을 보인 환자들의 뇌 영상 결과와의 연관성)

  • Kim, Sung Hun;Cho, Yong-Jin;Kim, Ho-Jin;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • Background and Objective : Visual evoked potentials(VEPs) is considered to be a reliable diagnostic procedure for examining patients with anterior visual pathways. Some abnormalities in the recordings on monocular stimulation have been said to indicate retrochiasmal lesion, but less consistent results have been reported. This study is to evaluate the positive predictability of VEP for the detection of retrochiasmal lesion. Methods : We reviewed VEPs that could be interpreted as indicative of a retrochiasmal lesions, based on amplitude or latency asymmetry recorded on the left(O1) and right(O2) occipital regions. Bilateral absent VEPs on both recording(O1 and O2) without evidence of prechiasmal lesion were included. During 5 years, we identified 31 patients who met the above criteria and who had undergone magnetic resonance imaging(MRI) of brain(one patient underwent computerized tomography). Twenty three patients underwent pattern reversal VEPs and others underwent flash goggle VEPs. Results : Brain imagings were abnormal in 29 and were normal in 2. Of the 29 abnormal scans, lesions in posterior visual pathway were detected in 21 scans(predictive value=68%). The predictive value was not significantly different between flash goggle VEP(75%) and pattern reversal VEP(68%). The predictive value was higher in patient with visual field defect(100%) than those without visual field defect(25%). The pathologic nature of lesion also showed close relations to the predictive value. VEPs is usually paradoxically lateralized(78%), but not in all patients. Conclusion : VEPs abnormalities suggesting retrochiasmal lesion were usually corresponded with brain MRI findings. Diagnostic reliability could be increased when considering the visual field defect and nature of lesion. Therefore, the authors suggest that VEPs studies could be useful in evaluating the patients with the retrochismal lesion.

  • PDF

Pituitary Macroincidentaloma - Report of 3 Cases - (Pituitary Macroincidentaloma - 증례보고 -)

  • Cho, Sung Jin;Shim, Jae Joon;Chang, Jae Chil;Kim, Bum Tae;Shin, Won Han;Choi, Soon Kwan;Byun, Bark Jang
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.1033-1036
    • /
    • 2001
  • With improvements in diagnostic imaging techniques for the brain, pituitary tumors without neurological signs or symptoms have occasionally been found. To evaluate therapeutic strategy for incidentally found pituitary tumors ("pituitary incidentaloma"), we analyzed the result of magnetic resonance imaging findings and of ophthalmological and endocrinological studies in 3 cases with follow up. Incidentally found functioning tumors were excluded. All of 3 cases is greater than 10mm in tumor size("pituitary macroincidentaloma"). The follow-up period was 49 months, 16 months and 6 months(mean, 25.3 months) in each case. There was no evidence of tumor enlargement, endocrinological problems and visual field defect during follow-up period. Patients with pituitary incidentalomas usually follow a benign course and neurosurgical intervention is not initially required in the management even those greater than 10mm in diameter. Observation over time may be good approach to the patient with a pituitary macroincidentaloma to avoid the unnecessary risk for surgery in a patients with a stable mass.

  • PDF

Time Reversal Focusing and Imaging of Point-Like Defects in Specimens with Nonplanar Surface Geometry

  • Jeong, Hyun-Jo;Lee, Hyun-Kee;Bae, Sung-Min;Lee, Jung-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.6
    • /
    • pp.569-577
    • /
    • 2010
  • Nonplanar surface geometries of components are frequently encountered in real ultrasonic inspection situations. Use of rigid array transducers can lead to beam defocusing and reduction of defect image quality due to the mismatch between the planar array and the changing surface. When a flexible array is used to fit the complex surface profile, the locations of array elements should be known to compute the delay time necessary for adaptive heam focusing. An alternative method is to employ the time reversal focusing technique that does not require a prior knowledge about the properties and structures of the specimen and the transducer. In this paper, a time reversal method is applied to simulate beam focusing of flexible arrays and imaging of point-like defects contained in specimens with nonplanar surface geometry. Quantitative comparisons are made for the performance of a number of array techniques in terms of the ability to focus and image three point-like reflectors positioned at regular intervals. The sinusoidal profile array studied here exhibits almost the same image quality as the flat, reference case.

Right ventricular failure in congenital heart disease

  • Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.101-106
    • /
    • 2013
  • Despite developments in surgical techniques and other interventions, right ventricular (RV) failure remains an important clinical problem in several congenital heart diseases (CHD). RV function is one of the most important predictors of mortality and morbidity in patients with CHD. RV failure is a progressive disorder that begins with myocardial injury or stress, neurohormonal activation, cytokine activation, altered gene expression, and ventricular remodeling. Pressure-overload RV failure caused by RV outflow tract obstruction after total correction of tetralogy of Fallot, pulmonary stenosis, atrial switch operation for transposition of the great arteries, congenitally corrected transposition of the great arteries, and systemic RV failure after the Fontan operation. Volume-overload RV failure may be caused by atrial septal defect, pulmonary regurgitation, or tricuspid regurgitation. Although the measurement of RV function is difficult because of many reasons, the right ventricle can be evaluated using both imaging and functional modalities. In clinical practice, echocardiography is the primary mode for the evaluation of RV structure and function. Cardiac magnetic resonance imaging is increasingly used for evaluating RV structure and function. A comprehensive evaluation of RV function may lead to early and optimal management of RV failure in patients with CHD.

Remote Cerebral and Cerebellar Hemorrhage after Massive Cerebrospinal Fluid Leakage

  • You, Sung-Hye;Son, Kyu-Ri;Lee, Nam-Joon;Suh, Jung-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.4
    • /
    • pp.240-243
    • /
    • 2012
  • Dural tears can occur during spinal surgery and may lead to cerebrospinal fluid (CSF) leakage which is rarely involved in remote cerebellar hemorrhage. Only a few of cases of simultaneous cerebral and cerebellar hemorrhage have been reported in the English literature. We experienced a case of multiple remote cerebral and cerebellar hemorrhages in a 63-year-old man who exhibited no significant neurologic deficits after spinal surgery. Magnetic resonance imaging (MRI) performed 4 days after the surgery showed a large amount of CSF leakage in the lumbosacral space. The patient underwent the second surgery for primary repair of the dural defect, but complained of headache after dural repair surgery. Brain MRI taken 6 days after the dural repair surgery revealed multifocal remote intracerebral and cerebellar hemorrhages in the right temporal lobe and both cerebellar hemispheres. We recommend diagnostic imaging to secure early identification and treatment of this complication in order to prevent serious neurologic deficits.

Osteosarcoma Arising in a Polyostotic Fibrous Dysplasia: A Case Report (다골성섬유형성이상에서 발생한 골육종: 증례 보고)

  • Suh, Kyung-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • Fibrous dysplasia is a skeletal developmental anomaly of the bone-forming mesenchyme that manifests as a defect in osteoblastic differentiation and maturation. It is a nonhereditary disorder of unknown cause. In fibrous dysplasia, the medullary bone is replaced by fibrous tissue, which appears various imaging findings. It is usually an incidental finding, generally not requiring further investigation. However, fibrous dysplasia may be complicated by pathologic fracture, and rarely by malignant degeneration. We present the image findings of a 44-year-old man who had a chondroblastic osteosarcoma arising from polyostotic fibrous dysplasia in the femur. Evidence of cortical destruction on plain radiography and soft tissue mass in the lesion on MR images suggested a tumor of malignant transformation.

  • PDF

Prestack migration using seismic interferometry (탄성파 간섭파를 이용한 중합전 구조보정)

  • Kim, Young-Wan;Jang, Seong-Hyung;Yoon, Wang-Jung;Suh, Sang-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.203-207
    • /
    • 2008
  • Prestack depth migration is used to image for complex geological structure such as faults, folds, and subsalt. In this case, it is widely used the surface reflection data as a input data. However, the surface reflection data have intrinsic problems to image the subsalt and the salt flank due to the complex wavefields and multiples which come from overburden. For overcoming the structural defect of the surface reflection data in the imaging, I used the virtual sources in terms of seismic interferometry to image the subsurface and suppress the multiples using the velocity model of the lower part of the virtual sources. The results of the prestack depth migration using virtual source gathers and velocity model below receivers are similar geological interfaces to the results from shot gathers of the conventional ocean bottom seismic survey. And especially artificial interfaces by multiples were suppressed without applying any other data processing to eliminate multiples. This study results by numerical modeling can make a valuable imaging tool when it is applied to satisfied field data for specific condition.

  • PDF

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

The Construction of Quality Inspection System for Sunroof Sealer Application Process Using SVM Algorithm (SVM 알고리즘을 활용한 선루프 실러도포 공정 품질검사 시스템 구축)

  • Yang, Hee-Jong;Jang, Gil-Sang
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2021
  • Recently, due to the aging of workers and the weakening of the labor base in the automobile industry, research on quality inspection methods through ICT(Information and Communication Technology) convergence is being actively conducted. A lot of research has already been done on the development of an automated system for quality inspection in the manufacturing process using image processing. However, there is a limit to detecting defects occurring in the automotive sunroof sealer application process, which is the subject of this study, only by image processing using a general camera. To solve this problem, this paper proposes a system construction method that collects image information using a infrared thermal imaging camera for the sunroof sealer application process and detects possible product defects based on the SVM(Support Vector Machine) algorithm. The proposed system construction method was actually tested and applied to auto parts makers equipped with the sunroof sealer application process, and as a result, the superiority, reliability, and field applicability of the proposed method were proven.