• Title/Summary/Keyword: Defect

Search Result 8,082, Processing Time 0.042 seconds

Comparative Review on Term of Warranty Liability of Reinforced Concrete Work through Occurred Defect Data Analysis in Apartment Building (공동주택 하자실적자료 분석을 통한 철근콘크리트 공사의 하자담보책임기간 비교연구)

  • Seo, Deok-Seok;Park, Jun-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.266-267
    • /
    • 2017
  • As apartment buildings defect lawsuits become socioeconomic problems, an objective basis system for the term of warranty liability of reinforced concrete constructions is urgent. This study was carried out as a basic study for developing a basis system for the term of warranty liability. To do this, defect data actual collected in apartment complexes were collected and analyzed. As the result of checking the cumulative rate of defect occurrence in reinforced concrete construction by year, the point of time of reaching the 90% level was the 5th years, which was similar with the provision of the Apartment Building Management Act. However, the current Supreme Court precedent has decided that the term of warranty liability for the main structural parts in reinforced concrete construction shall be 10 years and the dispute is expected to continue in the future in the defect lawsuit.

  • PDF

Comparative Analysis on the Defect Evaluation System in Apartment Buildings (공동주택 하자감정 평가체계의 비교 분석)

  • Kim, Min-Jeong;Park, Jun-Mo;Kim, Ok-Kyue;Seo, Deok-Suk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.111-112
    • /
    • 2012
  • The purpose of this study is to evaluate a defect in apartment buildings as review a safety investigation and consult a defect. As a result to compare a safety investigation to consult a defect, they are almost similar in spite of the purpose and the scope of evaluation are different. Therefore, it needs to establish a special and systemic system, and follow an organized effort about raising a consultant and improving an ability.

  • PDF

Surgical Treatment of Atrioventricular Septal Defect (방실중격결손증의 외과적 치료)

  • 이광숙
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.990-995
    • /
    • 1989
  • Since 1984, 24 patients underwent repair of atrioventricular septal defect. Nineteen had a partial defect and 5 had a complete atrioventricular septal defect. There were 9 men and 15 women, ranging in age from 1 to 50 years [mean age, 13.3 years]. Four patients had a Downs syndrome. Additional congenital heart defects were present in 11 patients. One patient had palliative operation prior to total correction. In partial defects, the primum atrial septal defect was closed with Xenomedica patch and the mitral valve was repaired with simple closure of the septal commissure. Central incompetence from annular dilatation was repaired by a local annuloplasty. In complete defect, the septal defects were closed with two patches except one. Operative mortality was 5% in partial defects and 60% in complete defects and low cardiac output was the commonest etiology. In a mean follow-up period of 27.9 months [range, 4 to 63 months] there were no late death and no instances of late-onset complete heart block. One patient required reoperation [MVR] for residual mitral regurgitation. The majority of patients were asymptomatic and mean postop. NYHA functional class was 1.2.

  • PDF

Failure Risk Assessment of Reinforced Concrete Sewer Pipes on Joint-Related Defects (원심력철근콘크리트관의 결함에 따른 심각도 평가 -이음부 사례를 중심으로-)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.787-796
    • /
    • 2013
  • Sewer joint-related defect is one of the most common domestic sewer defects along with the lateral pipe problem. However, there are currently no criteria that precisely assess the joint-related sewer defects. Therefore, this study examined the joint-related sewer defects found in domestic circumstances, classified them according to the suggested defect code, and presented the examples of defect pictures. Each defect code was organized as the process of out of pipeline alignment (OPA) which shows the progress in deterioration. Each defect was classified into 5 grades depending on appropriate repair and rehabilitation method. The result of this study is expected to be useful for domestic CCTV inspectors to assess the sewer condition and helpful for managers to make a decision of repair and rehabilitation.

Electrical Properties and Defect Types of Nb-doped $TiO_2$ (Nb를 첨가한 $TiO_2$ 의 전기적 성질 및 결함형태)

  • 이순일;백승봉;김명호
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.12
    • /
    • pp.1335-1341
    • /
    • 1999
  • The electrical conductivity ($\sigma$) of TiO2 doped with 0.05-4.0mol% Nb2O5 was measured in the oxygen partial pressure range of 10-17 to 100 atm and temperature range of 1100 to 130$0^{\circ}C$ to investigate the electrical properties and defect types. The oxygen partial pressure dependence of the electrical conductivity (log$\sigma$/logPo2) above 110$0^{\circ}C$ was divided into the four regions. From these experimental results the following defect regions were proposed ; 1) Magneli phase(extended defect) 2) reduced rutile region where intrinsic defect predominates 3) nearly stoichiometric region which is independent on the oxygen partical pressure and 4) overstoichiometric region which is not observed in pure TiO2 The electrical conductivity of Nb-doped TiO2 depended on the doping content the oxygen partial pressure and the measuring tem-perature.

  • PDF

Defect Detection Method using Human Visual System and MMTF (MMTF와 인간지각 특성을 이용한 결함성분 추출기법)

  • Huh, Kyung-Moo;Joo, Young-Bok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1094-1098
    • /
    • 2013
  • AVI (Automatic Vision Inspection) systems automatically detect defect features and measure their sizes via camera vision. Defect detection is not an easy process because of noises from various sources and optical distortion. In this paper the acquired images from a TFT panel are enhanced with the adoption of an HVS (Human Visual System). A human visual system is more sensitive on the defect area than the illumination components because it has greater sensitivity to variations of intensity. In this paper we modified an MTF (Modulation Transfer Function) in the Wavelet domain and utilized the characteristics of an HVS. The proposed algorithm flattens the inner illumination components while preserving the defect information intact.

Multilocular developmental salivary gland defect

  • Kim, Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.261-263
    • /
    • 2012
  • Developmental salivary gland defect is a bone depression on the lingual surface of the mandible containing salivary gland or fatty soft tissue. The most common location is within the submandibular gland fossa and often close to the inferior border of the mandible. This defect is asymptomatic and generally discovered only incidentally during radiographic examination of the area. This defect also appears as a well-defined, corticated, unilocular radiolucency below the mandibular canal. Although it is not uncommon for this defect to appear as a round or ovoid radiolucency, multilocular radiolucency of these defects is relatively rare. This report presents a case of a developmental salivary gland defect with multilocular radiolucency in a male patient.

Transient analysis of point defect dynamics in czochralski-grown silicon crystals

  • Wang, Jong-Hoe;Oh, Hyun-Jung;Park, Bong-Mo;Lee, Hong-Woo;Yoo, Hak-Do
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.6
    • /
    • pp.259-263
    • /
    • 2001
  • The continuum model of transient point defect dynamics to predict the concentrations of interstitial and vacancy is established by estimating expressions for the thermophysical properties of intrinsic point defects. And the point defect distribution in a Czochralski-grown 200 mm silicon crystal and the location of oxidation-induced stacking fault ring(OiSF-ring) created during the cooling of crystals are calculated by using the numerical analysis. The purpose of this paper is to show that his approach lead to predictions that are consistent with experimental results. Predicted point defect distributions by transient point defect dynamic analysis are in good qualitative agreement with experimental data under widely and abruptly varying crystal pull rates when correlated with the position of the OiSF-ring .

  • PDF

A Micro-defect Detection of Cold Rolled Steel (냉연 강판의 미세 결함 검출 기술)

  • Yun, Jong Pil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.247-252
    • /
    • 2016
  • In this paper, we propose a new defect detection technology for micro-defect on the surface of steel products. Due to depth and size of microscopic defect, slop of surface and vibration of strip, the conventional optical method cannot guarantee the detection performance. To solve the above-mentioned problems and increase signal to noise ratio, a novel retro-schlieren method that consists of retro reflector and knife edge is proposed. Moreover dual switching lighting method is also applied to distinguish uneven micro defects and surface noise. In proposed method, defective regions are represented by a black and white pattern. This pattern is detected by a defect detection algorithm with Gabor filter. Experimental results by simulator for sample defects of cold rolled steel show that the proposed method is effective.

A Study on the Term of Warranty Liability by the Law-suit Requesting of the Guarantee against Defects in the Apartment Building (공동주택 하자보증금 청구소송에 의한 하자담보책임기간 연구)

  • Koo, Hae-Shik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.11-18
    • /
    • 2012
  • The purpose of this study is to contribute to solution of the defect dispute in apartment house in advance. We want to propose the improved devices in defect problems by investigating the money that exacted from the practical business of the inspection company and the money that a judge gave a decision in a civil court in 50 cases of the lawsuit to requesting the guarantee against defects and the improved schemes of the applied rate by analyzing the diagnosis money of each applied years about the term of warranty liability in 40 cases of the lawsuit separately from that. As the result, we have to reflect the defect of non construction and error construction on apartment building defects, which recognizes very important factor when we compute the defect repair warranty money and it needs to be rearranged the applied ratio in guarantee peried of housing law practically.