• 제목/요약/키워드: Deep Litter Housing

검색결과 5건 처리시간 0.023초

돈사 작업장 유형에 따른 입자상 오염물질의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Concentrations and Emissions of Particulate Contaminants by Types of Swine Houses in Korea)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권2호
    • /
    • pp.141-146
    • /
    • 2005
  • Objectives: Particulate contaminants, such as total and respirable dusts, can harm the health of farm workers via several routes. The principal aims of this field study were to determine the concentrations and emissions of particulate contaminants: total and respirable dusts, in the different types of swine houses used in Korea, and allow objective comparison between Korea and the other countries in terms of swine housing types. Methods: The swine houses investigated in this research were selected with respect to three criteria: the manure removal system, ventilation mode and growth stage of pigs. Measurements of total and respirable dust concentrations and emissions in the swine houses were carried out on 5 housing types at 15 different farm sites per housing type. The swine houses investigated were randomly selected from farms situated within the central districts in Korea: province of Kyung-gi, Chung-buk and Chung-nam. Results: The total and respirable dust concentrations in the swine houses averaged $1.88\;and\;0.64mg/m^3$, ranging from $0.53\;to\;4.37mg/m^3$ and from $0.18\;to\;1.68mg/m^3$, respectively. The highest concentrations of total and respirable dusts were found in the swine houses with deep-litter bed systems: $2.94mg/m^3\;and\;1.14 mg/m^3$, while the lowest concentrations were found in the naturally ventilated buildings with slats: $0.83mg/m^3\;and\;0.24mg/m^3$, respectively (p<0.05). All the swine houses investigated did not exceed the threshold limit values (TLVs) for total ($10mg/m^3$) and respirable ($2.5mg/m^3$) dusts. The mean emissions of total and respirable dusts, per pig (75 kg in terms of live weight) and area ($m^2$), from the swine houses were 97.33 and 9.55 mg/h/pig and $37.14\;and\;12.83mg/h/m^2$, respectively. The swine houses with deep-litter bed systems showed the highest emissions of total and respirable dusts (p<0.05). However, the emissions of total and respirable dusts from the other swine houses were not significantly different (p>0.05). Conclusion: The concentrations and emissions of total and respirable dusts were relatively higher in the swine houses managed with deep-litter bed systems and ventilated naturally of the different swine housing types tested. In further research, more farms than the number used in this research should be investigated, which will present objective and accurate data on the concentrations and emissions of total and respirable dusts in Korean swine houses. In addition, personal sampling should be performed to objectively assess the exposure level of farm workers to particulate contaminants.

Minimizing the Environmental Pollution of Pig Husbandry and Waste Management

  • Mszros, Gy;Kuli, B.;Fenyvesi, L.;Mtys, L.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1395-1404
    • /
    • 1993
  • Application of water-saving self-feeders can reduce water consumption of pigs by more than 50% . so the feeding-watering system one of the most important way of the reduction of the slurry. Bioactive deep litter housing can eliminate slurry. Matured urine, faeces and litter can use for the purposes of soil conditioning and fertilizing . Water-saving slurry handling technology can halve manure dilution so it can double the nutrient content of the slurry. By using of straw bale biofilter for reducing emissions of pig houses makes fattening of pigs possible close to populated area. Developed rate control system for slurry application make avoiding over-fertilization possible , can fulfill better the demand of nutrient of plants. By means of computer aided manure utilization system area distribution of soil characteristics can determinate . The system is suitable for planning the utilization of manure and slurry in environment -friendly way.

  • PDF

돈사 작업장 유형에 따른 암모니아와 황화수소의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Emission Characteristics of Ammonia and Hydrogen Sulfide by Pig Building Types)

  • 김기연;박재범;김치년;이경종
    • 한국산업보건학회지
    • /
    • 제16권1호
    • /
    • pp.36-43
    • /
    • 2006
  • The principal aim of this field study was to determine the concentrations and emissions of gaseous contaminants such as ammonia and hydrogen sulfide in the different types of pig buildings in Korea and allow objective comparison between Korea and the other countries in terms of pig housing types. This field study was performed from May to June and from September to October in 2002. Pig buildings investigated in this research were selected in terms of three criteria; manure removal system, ventilation mode and growth stage of pig. Measurements of concentration and emission of ammonia and hydrogen sulfide in the pig buildings were done in 5 housing types and the visited farms were 15 sites per each housing type. Concentrations of ammonia and hydrogen sulfide were measured at three locations of the central alley in the pig building and emission rates of them were estimated by multiplying the average concentration($mg/m^3$) measured near the air outlet by the mean ventilation rate($m^3/h$) and expressed either per pig of liveweight 75kg(mg/h/pig) or per area($mg/h/m^2$). Concentrations of ammonia and hydrogen sulfide in the pig buildings were averaged to 7.5 ppm and 286.5 ppb and ranged from 0.8 to 21.4 ppm and from 45.8 to 1,235 ppb, respectively. The highest concentrations of ammonia and hydrogen sulfide were found in the mechanically ventilated buildings with slats; 12.1 ppm and 612.8 ppb, while the lowest concentrations of ammonia and hydrogen sulfide were found in the pig buildings with deep-litter bed system(2.2 ppm) and the naturally ventilated pig buildings with manure removal system by scraper(115.2 ppb), respectively(p<0.05). All the pig buildings were investigated not to exceed the threshold limit values(TLVs) of ammonia(25 ppm) and hydrogen sulfide(10 ppm). The mean emissions of ammonia and hydrogen sulfide per pig(75kg in terms of liveweight) and area($m^2$) from pig buildings were 250.2 mg/h/pig and 37.8 mg/h/pig and $336.3mg/h/m^2$ and $50.9mg/h/m^2$, respectively. The pig buildings with deep-litter bed system showed the lowest emissions of ammonia and hydrogen sulfide(p<0.05). However, the emissions of ammonia and hydrogen sulfide from the other pig buildings were not significantly different(p>0.05). Concentrations and emissions of ammonia and hydrogen sulfide were relatively higher in the pig buildings managed with deep-pit manure system with slats and mechanical ventilation mode than the different pig housing types. In order to prevent pig farm workers from adverse health effect caused by exposure to ammonia and hydrogen sulfide in pig buildings, they should wear the respirators during shift and be educated sustainably for the guideline related to occupational safety.

Antimicrobial resistance in fecal Escherichia coli from different pig production systems

  • Mitchaothai, Jamlong;Srikijkasemwat, Kanokrat
    • Animal Bioscience
    • /
    • 제35권1호
    • /
    • pp.138-146
    • /
    • 2022
  • Objective: The objective of the current study was to investigate the influences of conventional (CO) and deep litter (DE) systems on antimicrobial resistance in fecal Escherichia coli (E. coli). Methods: A cross-sectional study was carried out to detect antimicrobial resistance to E. coli in swine fecal samples in CO and DE systems located in western and northeastern Thailand. Individual rectal swab samples were taken only from healthy pigs. A total of 215 individual and healthy pigs were randomly selected for isolation and antimicrobial susceptibility test of E. coli by the disc diffusion method. The test panel included amoxicillin (AMX), colistin, doxycycline (DOX), enrofloxacin, gentamicin (GEN), kanamycin, neomycin (NEO), and trimethoprim-sulfamethoxazole (SXT). Results: There were significant (p<0.05) lower resistance levels for GEN, NEO, and SXT in the DE farms compared to those in the CO farms. There was a lower number of antimicrobial resistance agents (p<0.001) in the DE farms compared to those in the CO farms. This result was consistent with those in western (p<0.01) and northeastern (p<0.01) Thailand. Overall, antibiograms of AMX-SXT and AMX-DOX-SXT were found in the CO (19.09% and 20.91%, respectively) and the DE (16.19% and 24.76%, respectively) farms. No antimicrobial resistance (5.71%) was found and AMX (13.33%) resistant pigs in the DE farms, whereas the pattern of AMX-GEN-SXT (6.36%) and AMX-DOX-GEN-SXT (11.82%) resistant pigs was found in the CO farms. Conclusion: The DE system for pig farming was superior to conventional pig farming by lowering the resistance level of fecal E. coli to GEN, NEO, and SXT, with decreasing the number of antimicrobial resistance agents and inducing a small proportion of pigs to be free from antimicrobial resistance.

동물복지 관련 산란계 농가 실태조사 (A Farm on Laying Hens' Welfare in Korea)

  • 전중환;이준엽;박규현;김두환;송준익
    • 한국축산시설환경학회지
    • /
    • 제18권3호
    • /
    • pp.151-156
    • /
    • 2012
  • 본 조사는 산란계 케이지 사육시설에 대한 대체 사육시설 등 해결방안을 모색하기 위한 기초자료를 확보하기 위하여 평사, 방사사육 및 동물복지 사육시설을 사용하는 산란계 농가를 대상으로 사육시설에 대한 실태를 조사하였다. 사육형태는 방사사육, 평사사육 및 대체 사육시설 3가지로 구분되었으며, 축사형태는 무창축사와 개방축사 2가지로 구분할 수 있었다. 급이기는 선형과 원형이 각 37.5%와 62.5%로 조사되었으며, 급수기는 니플이 75%, 선형이 12.5%, 버켓이 12.5%로 조사되었다. 사육밀도의 경우 평균 5.6수/$m^2$로 조사한 모든 농가가 인증기준에 부합하였다. 횃대가 설치되어 있지 않은 곳이 25%에 달하였으며 횃대가 설치되어 있는 농가의 경우도 수당 15 cm 이상의 횃대가 제공되어야 하는 인증기준에 미달하는 것으로 조사되었다. 또한 전체 조사농가의 50%가 재래식 산란상을 사용하고 있으며 이로 인하여 인력수거 방식으로 집란하고 있었다.