• Title/Summary/Keyword: Deep Heat

Search Result 367, Processing Time 0.025 seconds

Evaluation of Heat Production in Deep Boreholes by Gamma-ray Logging (감마선 검층자료를 이용한 국내 대심도 시추공 암반의 열생산율 평가)

  • Jo, Yeonguk;Kim, Myung Sun;Lee, Keun-Soo;Park, In Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.1
    • /
    • pp.20-27
    • /
    • 2021
  • Subsurface rock produces heat from the decay of radioactive isotopes in constituent minerals and gamma-ray emissions, of which the magnitude is dominated by the contents of the major radioactive isotopes (e.g., U, Th, and K). The heat production is generally calculated from the rock density and contents of major isotopes, which can be determined by mass spectrometry of drilled core samples or rock fragments. However, such methods are not easily applicable to deep boreholes because core samples recovered from depths of several hundred meters to a few kilometers are rarely available. A geophysical logging technique for boreholes is available where the U, Th, and K contents are measured from the gamma-ray spectrum. However, this technique requires the density to be measured separately, and the measurement depth of the equipment is still limited. As an alternative method, a normal gamma-ray logging tool was adopted to estimate the heat production from the total gamma activity, which is relatively easy to measure. This technical report introduces the development of the proposed method for evaluating the heat production of a granitic rock mass with domestic commercial borehole logging tools, as well as its application to a ~2 km deep borehole for verification.

A Study on the Automation of Cam Heat Treatment Process using Deep Learning (딥러닝을 이용한 캠 열처리 공정 자동화에 관한 연구)

  • Choi, Sung-Yug
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.281-288
    • /
    • 2020
  • In this paper, we propose a control method to solve the surface hardness non-uniformity due to flow non-uniformity occurring in the heat treatment process of marine CAM. In the water cooling method including the decarbonization method, an automation device for deformation control has been developed and applied. LSTM was used to estimate the water cooling conditions, and the proposed method was found to be meaningful by improving the prototype results.

A Fundamentals Study on Heat Exchanger using Deep Ocean Water: Effects of Material on Heat Transfer Performance (심층수 이용 열교환기 개발을 위한 기초연구: 열교환기 재질이 열교환기 성능에 미치는 영향)

  • Kwon, Jeong-Tae;Lee, Chang-Kyung;Huh, Cheol;Cho, Meang-Ik;Kim, Ki-Young;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4658-4664
    • /
    • 2013
  • This paper presents the effects of the tube materials on the heat transfer performance of double-tube heat exchangers for the development of heat exchangers using deep sea water. Heat exchangers made of titanium, aluminum. stainless steel, iron, copper, and aluminum with carbon black 0.015mm and 0.15mm coating were tested. Also, the heat transfer rate of each heat exchanger was calculated by using EES program. The calculated values were compared with the experimental ones, and the deviations were less than 10%. From the above experiment and analysis, aluminum with carbon black 15 coating can be considered the most promising candidate for the replacement of titanium heat exchanger.

A Fundamentals study on Heat Exchanger using Deep Ocean Water: Effects of Corrosion on Heat Transfer Performance (심층수 이용 열교환기 개발을 위한 기초연구: 열교환기 부식이 열교환기 성능에 미치는 영향)

  • Kwon, Young-Chul;Lee, Seok-Hyun;Huh, Cheol;Cho, Meang-Ik;Lee, Chang-Kyung;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5377-5384
    • /
    • 2013
  • This paper presents the effects of the tube materials and corrosion on the heat transfer performance of double-tube heat exchangers for the development of heat exchangers using deep sea water. Heat exchangers made of titanium, aluminum. stainless steel, iron, copper, and aluminum with electro-deposition coatings(Carbon black_$15{\mu}m$, Carbon black_$150{\mu}m$) were tested. Also, the heat transfer rate of each heat exchanger was calculated by using EES program. For the acceleration of corrosion by sea water, the temperature of sea water $70^{\circ}C$ and the concentration of salt 3.5% were considered. And the specimens were immersed in sea water during 6 weeks. From the above experiment and analysis, aluminum with electro-deposition coating(Carbon black_$150{\mu}m$) can be considered the most promising candidate for the replacement of titanium heat exchanger.

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

A Study on Performance Evaluation of a Vertically Closed Deep Geothermal Circulation Simulator (수직 밀폐형 심부지열 순환 시뮬레이터의 성능 평가에 관한 연구)

  • Bae, Jung-Hyeong;Lee, Dong-Woon;Yoon, Chung-Man;Ryoo, Yeon-Su;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.8-17
    • /
    • 2016
  • While greenhouses have been utilized as a sustainable alternative to traditional soil farming, they are often powered by diesel boilers that necessitate vast amounts of non-renewable energy and emit toxic fumes. Thus, geothermal heat pumps have been proposed as a more energy-efficient substitution for diesel boilers. Currently, most horticultural facilities in the United States use shallow geothermal systems, and are often equipped with horizontal underground heat exchangers as well as heat pump equipment. These shallow geothermal systems require a large drilling site and heat pump to function, which results in high maintenance costs. The heat pump itself consumes a large amount of power, which degrades system performance. Conversely, high temperatures can be attained within a single borehole in deep geothermal vertical closing systems without using a heat pump. This setup can dramatically reduce the power consumption and improve system performance. In this study, we have modeled a circulation simulator after the circulation systems in deep geothermal facilities to analyze a 2000-meter borehole in Naju-Sanpo-myeon. The simulator is operated by manipulating various putative parameters affecting system performance to analyze the system's coefficient of performance.

The Simulations on the Formability of AZ31 Magnesium Alloy Sheet in Warm Deep Drawing (AZ31 마그네슘합금판의 온간 디프드로잉 성형성해석)

  • Kang, Dae-Min;Hwang, Jong-Kwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • The material used is a commercial magnesium based alloy AZ31(Mg-3Al-1Zn)sheet with a thickness of 1.0mm. Uniaxial tension tests at warm temperature were carried out to investigate the material characteristics of K, m, and n. A warm drawing process with a local heating and cooling technique was developed to improve formability in this study with results of uniaxial tension tests because it is very difficult for Mg alloy to deform at room temperature by the conventional method. The die and blank holder were heated up, while the punch was water-cooled during deformation. FE simulations considering heat transfer were executed with Mg alloy to investigate the Improvement of deep drawability. For the assessment of improvement those were compare with the results of no considering heat transfer and room temperature.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF