• 제목/요약/키워드: Dedicated reader

검색결과 6건 처리시간 0.02초

134.2kHz 대역의 RFID 루프안테나 설계에 관한 연구 (A Study on the 134.2kHz Band RFID(Radio Frequency Identification) Loop Antenna Design)

  • 강민수;이동선;이기서
    • 한국철도학회논문집
    • /
    • 제4권3호
    • /
    • pp.102-109
    • /
    • 2001
  • In this paper, it has a proposal of the RFID reader antenna design that expand the dedicated short-range communication distance between a static object on the ground and a mobile object attached on the moving article. The static reader equipped with micro-processor makes it possible to have a serial communication with a main system, so that much data can be transfer to the main system. An antenna is adjusted in order to a communication, the scale is designed by results values of simulation using matlab. It is achieved to systematically manage logistics, person resource and security system by grasping the information and location of mobile object on the basis that this system receives the information between a static reader and a mobile object tag at 134.2kHz band on real time, also to make it possible the main system to process. Therefore, the reader antenna scale is controlled on the foundation of a magnetic field theory in order to expand a recognition distance of reader and tag, so that can be optimistically recognized with minimizing the direction influence of reader and tag.

  • PDF

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas

  • Riccardo Sartoris;Alberto Calandra;Kyung Jin Lee;Tobias Gauss;Valerie Vilgrain;Maxime Ronot
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1300-1309
    • /
    • 2021
  • Objective: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease. Materials and Methods: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots. Results: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89). Conclusion: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.

Use of Artificial Intelligence for Reducing Unnecessary Recalls at Screening Mammography: A Simulation Study

  • Yeon Soo Kim;Myoung-jin Jang;Su Hyun Lee;Soo-Yeon Kim;Su Min Ha;Bo Ra Kwon;Woo Kyung Moon;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • 제23권12호
    • /
    • pp.1241-1250
    • /
    • 2022
  • Objective: To conduct a simulation study to determine whether artificial intelligence (AI)-aided mammography reading can reduce unnecessary recalls while maintaining cancer detection ability in women recalled after mammography screening. Materials and Methods: A retrospective reader study was performed by screening mammographies of 793 women (mean age ± standard deviation, 50 ± 9 years) recalled to obtain supplemental mammographic views regarding screening mammography-detected abnormalities between January 2016 and December 2019 at two screening centers. Initial screening mammography examinations were interpreted by three dedicated breast radiologists sequentially, case by case, with and without AI aid, in a single session. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate for breast cancer diagnosis were obtained and compared between the two reading modes. Results: Fifty-four mammograms with cancer (35 invasive cancers and 19 ductal carcinomas in situ) and 739 mammograms with benign or negative findings were included. The reader-averaged AUC improved after AI aid, from 0.79 (95% confidence interval [CI], 0.74-0.85) to 0.89 (95% CI, 0.85-0.94) (p < 0.001). The reader-averaged specificities before and after AI aid were 41.9% (95% CI, 39.3%-44.5%) and 53.9% (95% CI, 50.9%-56.9%), respectively (p < 0.001). The reader-averaged sensitivity was not statistically different between AI-unaided and AI-aided readings: 89.5% (95% CI, 83.1%-95.9%) vs. 92.6% (95% CI, 86.2%-99.0%) (p = 0.053), although the sensitivities of the least experienced radiologists before and after AI aid were 79.6% (43 of 54 [95% CI, 66.5%-89.4%]) and 90.7% (49 of 54 [95% CI, 79.7%-96.9%]), respectively (p = 0.031). With AI aid, the reader-averaged recall rate decreased by from 60.4% (95% CI, 57.8%-62.9%) to 49.5% (95% CI, 46.5%-52.4%) (p < 0.001). Conclusion: AI-aided reading reduced the number of recalls and improved the diagnostic performance in our simulation using women initially recalled for supplemental mammographic views after mammography screening.

전자책 시장의 현황과 전망 (Electronic Books' Marketplaces : Status quo and Perspective)

  • 김은정;김솔미
    • 정보관리연구
    • /
    • 제32권1호
    • /
    • pp.71-86
    • /
    • 2001
  • 다양한 전자출판 기술의 발달로 인해 1990년대 중반부터 전자책이 보급되면서 전용단말기가 개발되었다. 다양한 단말기의 개발과 이동통신기기의 발달로 컨텐츠로서 전자책 보급이 확산되면서 정보자료로서 그 중요성이 더해가고 있다. 이 글에서는 전자책의 특징, 종류 등에 관해서 전반적으로 살펴보고, 현재 전자책 관련 기술과 표준에 대해 국내외 현황 및 시장동향을 고찰해 보고자 한다.

  • PDF

Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

  • So Yeon Cha;EunJu Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.922-930
    • /
    • 2021
  • Objective: It is uncertain why a b-value range of 1500-2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. Materials and Methods: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. Results: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm2 and 1640-1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835-1895 s/mm2 and 1705-1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm2 and 1573-1867 s/mm2 for reader 1, and 1775-1945 s/mm2 and 1591-1955 s/mm2 for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values. Conclusion: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm2.

장애인 접근성 향상을 위한 보조기기 및 대체자료 분석과 구현 방향 (The Implementation Directions and an Analysis of Assistive Devices and Alternative Formats to Improve Accessibility for Disabled People)

  • 임명환;길연희;전광일
    • 한국콘텐츠학회논문지
    • /
    • 제15권7호
    • /
    • pp.664-673
    • /
    • 2015
  • 장애인에 대한 정책과 지원, 장애인 접근성 향상을 위한 지침 제정, 기술혁신과 제품개발 등으로 장애인 보조기기 분야는 산업측면에서 크게 부각되고 있다. 최근에는 ICT 발전으로 시각 장애인용 스크린 리더, 점자 디스플레이, 화면 확대기, 문자음성 변환기 등이 출시되어 촉각과 청각으로 인터넷 접속이 용이해지고 스마트기기를 통해 편리하게 전자출판 콘텐츠를 활용하고 메일을 주고받을 수 있게 된 것이다. 그렇지만 급속하게 전환되고 있는 디지털 미디어기반의 스마트시대에 시각 장애인의 접근성은 아직도 열악하고 보조기기와 대체자료의 성능과 품질도 개선되어야 할 점이 많은 상황이다. 따라서 본 연구는 연구개발 혁신 측면에서 시각 장애인용 보조기기 및 대체자료의 현황과 구조를 분석하고 접근성 향상을 위한 구현 방향을 제시하고 있다. 연구결과, 향후에는 다양한 디지털 정보가 맞춤형 및 실감형 형태로 전환되고 장애인 전용 단말기 또는 스마트기기를 통해 유통될 것으로 예상된다.